Literature DB >> 20150304

Treatment of intracranial aneurysms by functional reconstruction of the parent artery: the Budapest experience with the pipeline embolization device.

I Szikora1, Z Berentei, Z Kulcsar, M Marosfoi, Z S Vajda, W Lee, A Berez, P K Nelson.   

Abstract

BACKGROUND AND
PURPOSE: Aneurysm treatment by intrasaccular packing has been associated with a relatively high rate of recurrence. The use of mesh tubes has recently gained traction as an alternative therapy. This article summarizes the midterm results of using an endoluminal sleeve, the PED, in the treatment of aneurysms.
MATERIALS AND METHODS: A total of 19 wide-neck aneurysms were treated in 18 patients: 10 by implantation of PEDs alone and 9 by a combination of PED and coils. Angiographic and clinical results were recorded immediately and at 6 months following treatment.
RESULTS: Immediate angiographic occlusion was achieved in 4 and flow reduction, in another 15 aneurysms. Angiography at 6 months demonstrated complete occlusion in 17 and partial filling in 1 of 18 patients. There was no difference between coil-packed and unpacked aneurysms. Of 28 side branches covered by > or =1 device, the ophthalmic artery was absent immediately in 1 and at 6 months in another 2 cases. One patient experienced abrupt in-stent thrombosis resulting in a transient neurologic deficit, and 1 patient died due to rupture of a coexisting aneurysm. All giant aneurysms treated with PED alone were demonstrated by follow-up cross-sectional imaging to have involuted by 6 months.
CONCLUSIONS: Treatment of large, wide-neck, or otherwise untreatable aneurysms with functional reconstruction of the parent artery may be achieved with relative safety using dedicated flow-modifying devices with or without adjunctive use of intrasaccular coil packing.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20150304      PMCID: PMC7963954          DOI: 10.3174/ajnr.A2023

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  32 in total

1.  Preliminary experience with the enterprise stent for endovascular treatment of complex intracranial aneurysms: potential advantages and limiting characteristics.

Authors:  Boris Lubicz; Olivier François; Marc Levivier; Jacques Brotchi; Danielle Balériaux
Journal:  Neurosurgery       Date:  2008-05       Impact factor: 4.654

2.  Saccular aneurysm formation in curved and bifurcating arteries.

Authors:  G N Foutrakis; H Yonas; R J Sclabassi
Journal:  AJNR Am J Neuroradiol       Date:  1999-08       Impact factor: 3.825

3.  Anatomically shaped internal carotid artery aneurysm in vitro model for flow analysis to evaluate stent effect.

Authors:  Krisztina Baráth; Francis Cassot; Daniel A Rüfenacht; Jean H D Fasel
Journal:  AJNR Am J Neuroradiol       Date:  2004 Nov-Dec       Impact factor: 3.825

4.  Effects of size and shape (aspect ratio) on the hemodynamics of saccular aneurysms: a possible index for surgical treatment of intracranial aneurysms.

Authors:  H Ujiie; H Tachibana; O Hiramatsu; A L Hazel; T Matsumoto; Y Ogasawara; H Nakajima; T Hori; K Takakura; F Kajiya
Journal:  Neurosurgery       Date:  1999-07       Impact factor: 4.654

5.  Treatment of a middle cerebral artery bifurcation aneurysm using a double neuroform stent "Y" configuration and coil embolization: technical case report.

Authors:  Sepehr Sani; Demetrius Klee Lopes
Journal:  Neurosurgery       Date:  2005-07       Impact factor: 4.654

6.  Usefulness of the Neuroform stent for the treatment of cerebral aneurysms: results at initial (3-6-mo) follow-up.

Authors:  David Fiorella; Felipe C Albuquerque; Vivek R Deshmukh; Cameron G McDougall
Journal:  Neurosurgery       Date:  2005-06       Impact factor: 4.654

7.  Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms.

Authors:  David Fiorella; Felipe C Albuquerque; Patrick Han; Cameron G McDougall
Journal:  Neurosurgery       Date:  2004-01       Impact factor: 4.654

8.  Curative reconstruction of a giant midbasilar trunk aneurysm with the pipeline embolization device.

Authors:  David Fiorella; Michael E Kelly; Felipe C Albuquerque; Peter K Nelson
Journal:  Neurosurgery       Date:  2009-02       Impact factor: 4.654

9.  Endovascular treatment of fusiform aneurysms with stents and coils: technical feasibility in a swine model.

Authors:  T F Massoud; F Turjman; C Ji; F Viñuela; G Guglielmi; Y P Gobin; G R Duckwiler
Journal:  AJNR Am J Neuroradiol       Date:  1995 Nov-Dec       Impact factor: 3.825

10.  A new self-expandable nitinol stent for the treatment of wide-neck aneurysms: initial clinical experience.

Authors:  J P P Peluso; W J van Rooij; M Sluzewski; G N Beute
Journal:  AJNR Am J Neuroradiol       Date:  2008-04-24       Impact factor: 3.825

View more
  164 in total

1.  Delayed ipsilateral parenchymal hemorrhage following flow diversion for the treatment of anterior circulation aneurysms.

Authors:  J P Cruz; M Chow; C O'Kelly; B Marotta; J Spears; W Montanera; D Fiorella; T Marotta
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-08       Impact factor: 3.825

Review 2.  Review of 2 decades of aneurysm-recurrence literature, part 1: reducing recurrence after endovascular coiling.

Authors:  E Crobeddu; G Lanzino; D F Kallmes; H J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-15       Impact factor: 3.825

3.  Pipeline in clinical practice in 2011.

Authors:  David Fiorella
Journal:  Neuroradiology       Date:  2011-09-29       Impact factor: 2.804

4.  Endovascular treatment of a ruptured blood blister-like aneurysm with a flow-diverting stent.

Authors:  S Rasskazoff; J Silvaggio; P A Brouwer; A Kaufmann; A Nistor; D Iancu
Journal:  Interv Neuroradiol       Date:  2010-10-25       Impact factor: 1.610

5.  Flow diversion for cerebral aneurysms: a cautionary tale.

Authors:  H J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2010-11-11       Impact factor: 3.825

6.  An in vitro study of silk stent morphology.

Authors:  Thaweesak Aurboonyawat; Raphaël Blanc; Paul Schmidt; Michel Piotin; Laurent Spelle; Amir Nakib; Jacques Moret
Journal:  Neuroradiology       Date:  2010-10-28       Impact factor: 2.804

7.  Flow-diverter silk stent for the treatment of intracranial aneurysms: 1-year follow-up in a multicenter study.

Authors:  J Berge; A Biondi; P Machi; H Brunel; L Pierot; J Gabrillargues; K Kadziolka; X Barreau; V Dousset; A Bonafé
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-02       Impact factor: 3.825

8.  Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment.

Authors:  J R Cebral; F Mut; M Raschi; E Scrivano; R Ceratto; P Lylyk; C M Putman
Journal:  AJNR Am J Neuroradiol       Date:  2010-11-11       Impact factor: 3.825

9.  Silk flow-diverter stent for the treatment of complex intracranial aneurysms: A one-year follow-up multicenter study.

Authors:  G Foa Torres; F Roca; A Noguera; J Godes; S Petrocelli; I Aznar; S Ales; P Muszynski; R Maehara; M Vicente; J M Pumar
Journal:  Interv Neuroradiol       Date:  2018-05-02       Impact factor: 1.610

10.  Treatment of complex intracranial aneurysms using flow-diverting silk® stents. An analysis of 32 consecutive patients.

Authors:  Ramazan Buyukkaya; Hasan Kocaeli; Nalan Yildirim; Hakan Cebeci; Cüneyt Erdogan; Bahattin Hakyemez
Journal:  Interv Neuroradiol       Date:  2014-12-05       Impact factor: 1.610

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.