Literature DB >> 22005692

Treatment of intracranial aneurysms using flow-diverting silk stents (BALT): a single centre experience.

M Leonardi1, L Cirillo, F Toni, M Dall'olio, C Princiotta, A Stafa, L Simonetti, R Agati.   

Abstract

The Silk stent (Balt, Montmorency, France) is a retractable device designed to achieve curative reconstruction of the parent artery associated with an intracranial aneurysm. We present our initial experience with the Silk flow-diverting stent in the management and follow-up of 25 patients presenting with intracranial aneurysms.Twenty-five patients (age range, 34-81 years; 24 female) were treated with the Silk flow-diverting device. Aneurysms ranged in size from small (5), large (10) and giant (10) and included wide-necked aneurysms, multiple, nonsaccular, and recurrent intracranial aneurysms. Nine aneurysms were treated for headache, 14 for mass effect. None presented with haemorrhage. All patients were pretreated with dual antiplatelet medications for at least 72 hours before surgery and continued taking both agents for at least three months after treatment. A total of 25 Silk stents were used. Control MR angiography and/or CT angiography was typically performed prior to discharge and at one, three, six and 12 months post treatment. A follow-up digital subtraction angiogram was performed between six and 19 months post treatment.Complete angiographic occlusion or subtotal occlusion was achieved in 15 patients in a time frame from three days to 12 months. Three deaths and one major complication were encountered during the study period. Two patients, all with cavernous giant aneurysms, experienced transient exacerbations of preexisting cranial neuropathies and headache after the Silk treatment. Both were treated with corticosteroids, and symptoms resolved completely within a month.In our experience the Silk stent has proven to be a valuable tool in the endovascular treatment of intracranial giant partially thrombosed aneurysms and aneurysms of the internal carotid artery cavernous segment presenting with mass effect. The time of complete occlusion of the aneurysms and the risk of the bleeding is currently not predictable.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22005692      PMCID: PMC3396033          DOI: 10.1177/159101991101700305

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  24 in total

1.  Histopathologic analysis of in-stent neointimal regression in a porcine coronary model.

Authors:  W H Kim; M K Hong; R Virmani; R Kornowski; R Jones; M B Leon
Journal:  Coron Artery Dis       Date:  2000-05       Impact factor: 1.439

2.  Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment.

Authors:  J R Cebral; F Mut; M Raschi; E Scrivano; R Ceratto; P Lylyk; C M Putman
Journal:  AJNR Am J Neuroradiol       Date:  2010-11-11       Impact factor: 3.825

3.  Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment.

Authors:  Z Kulcsár; E Houdart; A Bonafé; G Parker; J Millar; A J P Goddard; S Renowden; G Gál; B Turowski; K Mitchell; F Gray; M Rodriguez; R van den Berg; A Gruber; H Desal; I Wanke; D A Rüfenacht
Journal:  AJNR Am J Neuroradiol       Date:  2010-11-11       Impact factor: 3.825

4.  Early fatal hemorrhage after endovascular cerebral aneurysm treatment with a flow diverter (SILK-Stent): do we need to rethink our concepts?

Authors:  Bernd Turowski; Stephan Macht; Zolt Kulcsár; Daniel Hänggi; Walter Stummer
Journal:  Neuroradiology       Date:  2010-03-26       Impact factor: 2.804

5.  Treatment of intracranial aneurysms by functional reconstruction of the parent artery: the Budapest experience with the pipeline embolization device.

Authors:  I Szikora; Z Berentei; Z Kulcsar; M Marosfoi; Z S Vajda; W Lee; A Berez; P K Nelson
Journal:  AJNR Am J Neuroradiol       Date:  2010-02-11       Impact factor: 3.825

6.  Treatment of carotid siphon aneurysms with a microcell stent. A case report.

Authors:  M Leonardi; M Dall'olio; C Princiotta; L Simonetti
Journal:  Interv Neuroradiol       Date:  2009-01-05       Impact factor: 1.610

7.  Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience.

Authors:  Pedro Lylyk; Carlos Miranda; Rosana Ceratto; Angel Ferrario; Esteban Scrivano; Hugh Ramirez Luna; Aaron L Berez; Quang Tran; Peter K Nelson; David Fiorella
Journal:  Neurosurgery       Date:  2009-04       Impact factor: 4.654

8.  An original flow diversion device for the treatment of intracranial aneurysms: evaluation in the rabbit elastase-induced model.

Authors:  Chander Sadasivan; Liliana Cesar; Jaehoon Seong; Audrey Rakian; Qing Hao; Fermin O Tio; Ajay K Wakhloo; Baruch B Lieber
Journal:  Stroke       Date:  2009-01-15       Impact factor: 7.914

9.  International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion.

Authors:  Andrew J Molyneux; Richard S C Kerr; Ly-Mee Yu; Mike Clarke; Mary Sneade; Julia A Yarnold; Peter Sandercock
Journal:  Lancet       Date:  2005 Sep 3-9       Impact factor: 79.321

10.  Retreatment of ruptured cerebral aneurysms in patients randomized by coiling or clipping in the International Subarachnoid Aneurysm Trial (ISAT).

Authors:  Adriana Campi; Najib Ramzi; Andrew J Molyneux; Paul E Summers; Richard S C Kerr; Mary Sneade; Julia A Yarnold; Joan Rischmiller; James V Byrne
Journal:  Stroke       Date:  2007-03-29       Impact factor: 7.914

View more
  26 in total

Review 1.  Flow-diverter devices in the treatment of intracranial aneurysms: A meta-analysis and systematic review.

Authors:  Xianli Lv; Hongchao Yang; Peng Liu; Youxiang Li
Journal:  Neuroradiol J       Date:  2016-02-02

Review 2.  Endovascular treatment of cerebral aneurysms using flow-diverter devices: A systematic review.

Authors:  Francesco Briganti; Giuseppe Leone; Mariano Marseglia; Giuseppe Mariniello; Ferdinando Caranci; Arturo Brunetti; Francesco Maiuri
Journal:  Neuroradiol J       Date:  2015-08-27

3.  Hybrid, Y-configured, dual stent-assisted coil embolization in the treatment of wide-necked bifurcation aneurysms.

Authors:  Erol Akgul; Tugsan Balli; Erol H Aksungur
Journal:  Interv Neuroradiol       Date:  2015-02       Impact factor: 1.610

4.  Evaluation of CTA, time-resolved 4D CE-MRA and DSA in the follow-up of an intracranial aneurysm treated with a flow diverter stent: Experience from a single case.

Authors:  Georgios Kapsas; Caterina Budai; Francesco Toni; Francesco Patruno; Anna Federica Marliani; Marco Leonardi; Luigi Cirillo
Journal:  Interv Neuroradiol       Date:  2015-02       Impact factor: 1.610

5.  Long-term occlusion results with SILK flow diversion in 28 aneurysms: Do recanalizations occur during follow-up?

Authors:  Anastasios Mpotsaris; Martin Skalej; Oliver Beuing; Bernd Eckert; Daniel Behme; Werner Weber
Journal:  Interv Neuroradiol       Date:  2015-05-26       Impact factor: 1.610

Review 6.  Is flow diversion the death of cerebral bypass and coiling/stent-assisted coiling for giant cavernous aneurysms? A critical review on comparative outcomes and ongoing clinical trials.

Authors:  Tobias A Mattei; Andrew S Ferrell; Gavin W Britz
Journal:  Neurosurg Rev       Date:  2013-04-18       Impact factor: 3.042

7.  Treatment of intracranial aneurysms using the pipeline flow-diverter embolization device: a single-center experience with long-term follow-up results.

Authors:  I Saatci; K Yavuz; C Ozer; S Geyik; H S Cekirge
Journal:  AJNR Am J Neuroradiol       Date:  2012-07-19       Impact factor: 3.825

8.  Treatment of complex intracranial aneurysms using flow-diverting silk® stents. An analysis of 32 consecutive patients.

Authors:  Ramazan Buyukkaya; Hasan Kocaeli; Nalan Yildirim; Hakan Cebeci; Cüneyt Erdogan; Bahattin Hakyemez
Journal:  Interv Neuroradiol       Date:  2014-12-05       Impact factor: 1.610

9.  Vertebro-basilar junction aneurysms: a single centre experience and meta-analysis of endovascular treatments.

Authors:  Francesca Graziano; Mario Ganau; Domenico Gerardo Iacopino; Edoardo Boccardi
Journal:  Neuroradiol J       Date:  2014-12-01

10.  Complications in the treatment of intracranial aneurysms with silk stents: an analysis of 30 consecutive patients.

Authors:  L Cirillo; M Leonardi; M Dall'olio; C Princiotta; A Stafa; L Simonetti; F Toni; R Agati
Journal:  Interv Neuroradiol       Date:  2012-12-03       Impact factor: 1.610

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.