Literature DB >> 26003792

128-slice CT angiography of the aorta without ECG-gating: efficacy of faster gantry rotation time and iterative reconstruction in terms of image quality and radiation dose.

Vincenzo Russo1, Monica Garattoni2, Francesco Buia2, Domenico Attinà2, Luigi Lovato2, Maurizio Zompatori2.   

Abstract

OBJECTIVE: To evaluate image quality and radiation dose of non ECG-gated 128-slice CT angiography of the aorta (CTAA) with fast gantry rotation time and iterative reconstruction.
METHODS: Four hundred and eighty patients underwent non ECG-gated CTAA. Qualitative and quantitative image quality assessments were performed. Radiation dose was assessed and compared with the dose of patients who underwent ECG-gated CTAA (n = 126) and the dose of previous CTAA performed with another CT (n = 339).
RESULTS: Image quality (aortic root-ascending portion) was average-to-excellent in more than 94% of cases, without any non-diagnostic scan. For proximal coronaries, image quality was average-to-excellent in more than 50%, with only 21.5% of non-diagnostic cases. Quantitative analysis results were also good. Mean radiation dose for thoracic CTAA was 5.6 mSv versus 20.6 mSv of ECG-gated protocol and 20.6 mSv of 16-slice CTAA scans, with an average dose reduction of 72.8% (p < 0.001). Mean radiation dose for thoracic-abdominal CTAA was 9.7 mSv, versus 20.9 mSv of 16-slice CTAA scans, with an average dose reduction of 53.6% (p < 0.001).
CONCLUSIONS: Non ECG-gated 128-slice CTAA is feasible and able to provide high quality visualization of the entire aorta without significant motion artefacts, together with a considerable dose and contrast media volume reduction. KEY POINTS: • CT image quality of aortic root-ascending aorta is challenging. • Non ECG-gated scans are often limited by pulsatility artefacts. • ECG-gated examinations are usually limited by high radiation doses. • Non ECG-gated 128-slice low dose CTAA provides high quality images. • 128-slice CTAA low dose protocol could frequently replace ECG-gated CTAA.

Entities:  

Keywords:  Aorta; Image quality; Iterative reconstruction; Multidetector CT; Radiation dosage

Mesh:

Substances:

Year:  2015        PMID: 26003792     DOI: 10.1007/s00330-015-3848-3

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  24 in total

Review 1.  Initial experience with the clinical use of a 16 detector row CT system.

Authors:  Bernd J Wintersperger; Peter Herzog; Tobias Jakobs; Maximilian F Reiser; Christoph R Becker
Journal:  Crit Rev Comput Tomogr       Date:  2002-08

Review 2.  Multidetector row computed tomography of the aorta and peripheral arteries.

Authors:  Leo P Lawler; Elliot K Fishman
Journal:  Cardiol Clin       Date:  2003-11       Impact factor: 2.213

3.  Prospective ECG-gated 320-row CT angiography of the whole aorta and coronary arteries.

Authors:  Yu Li; Zhanming Fan; Lei Xu; Lin Yang; Haiyan Xin; Nan Zhang; Zhaoqi Zhang
Journal:  Eur Radiol       Date:  2012-06-04       Impact factor: 5.315

Review 4.  Acute aortic syndromes: new insights from electrocardiographically gated computed tomography.

Authors:  Dominik Fleischmann; R Scott Mitchell; D Craig Miller
Journal:  Semin Thorac Cardiovasc Surg       Date:  2008

5.  Performance of iterative reconstruction and automated tube voltage selection on the image quality and radiation dose in abdominal CT scans.

Authors:  Gaurav S Desai; Jorge M Fuentes Orrego; Avinash R Kambadakone; Dushyant V Sahani
Journal:  J Comput Assist Tomogr       Date:  2013 Nov-Dec       Impact factor: 1.826

6.  Impact of Adaptive Statistical Iterative Reconstruction (ASIR) on radiation dose and image quality in aortic dissection studies: a qualitative and quantitative analysis.

Authors:  Daniel Cornfeld; Gary Israel; Ezra Detroy; Jamal Bokhari; Hamid Mojibian
Journal:  AJR Am J Roentgenol       Date:  2011-03       Impact factor: 3.959

7.  Triple rule-out acute chest pain evaluation using a 320-row-detector volume CT: a comparison of the wide-volume and helical modes.

Authors:  Eun-Ju Kang; Ki-Nam Lee; Dong Won Kim; Bo Sung Kim; Sunseob Choi; Byeong-Ho Park; Jong Young Oh
Journal:  Int J Cardiovasc Imaging       Date:  2012-05-23       Impact factor: 2.357

8.  Comparison of radiation dose and image quality of triple-rule-out computed tomography angiography between conventional helical scanning and a strategy incorporating sequential scanning.

Authors:  Eric D Manheimer; M Robert Peters; Steven D Wolff; Mehreen A Qureshi; Prashanth Atluri; Gregory D N Pearson; Andrew J Einstein
Journal:  Am J Cardiol       Date:  2011-04-01       Impact factor: 2.778

9.  Thoracoabdominal-aortoiliac multidetector-row CT angiography at 80 and 100 kVp: assessment of image quality and radiation dose.

Authors:  Sebastian T Schindera; Patricia Graca; Michael A Patak; Susanne Abderhalden; Gabriel von Allmen; Peter Vock; Zsolt Szucs-Farkas
Journal:  Invest Radiol       Date:  2009-10       Impact factor: 6.016

10.  Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience.

Authors:  Daniele Marin; Rendon C Nelson; Sebastian T Schindera; Samuel Richard; Richard S Youngblood; Terry T Yoshizumi; Ehsan Samei
Journal:  Radiology       Date:  2010-01       Impact factor: 11.105

View more
  4 in total

1.  High-pitch dual-source CT angiography without ECG-gating for imaging the whole aorta: intraindividual comparison with standard pitch single-source technique without ECG gating.

Authors:  Carmelinda Manna; Mario Silva; Rocco Cobelli; Sara Poggesi; Cristina Rossi; Nicola Sverzellati
Journal:  Diagn Interv Radiol       Date:  2017 Jul-Aug       Impact factor: 2.630

Review 2.  Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

Authors:  Benjamin M Yeh; Paul F FitzGerald; Peter M Edic; Jack W Lambert; Robert E Colborn; Michael E Marino; Paul M Evans; Jeannette C Roberts; Zhen J Wang; Margaret J Wong; Peter J Bonitatibus
Journal:  Adv Drug Deliv Rev       Date:  2016-09-09       Impact factor: 15.470

3.  Diagnostic Value of Multi-Slice Spiral Computed Tomography for Bronchial Dysplasia in Premature Infants.

Authors:  Weiwei Zhang; Shaohua Wang
Journal:  Med Sci Monit       Date:  2018-10-15

4.  Association of Difference in Coronary Sinus Diameter by Computed Tomographic Angiography Between Patients in and Not in Stable Atherosclerotic Plaque(S).

Authors:  Yancui Li; Wen Liang; Jianchun Zhang; Ruchen Peng
Journal:  Med Sci Monit       Date:  2018-05-18
  4 in total