Literature DB >> 21343485

Impact of Adaptive Statistical Iterative Reconstruction (ASIR) on radiation dose and image quality in aortic dissection studies: a qualitative and quantitative analysis.

Daniel Cornfeld1, Gary Israel, Ezra Detroy, Jamal Bokhari, Hamid Mojibian.   

Abstract

OBJECTIVE: The purpose of the study was to quantify the radiation dose reduction achieved when imaging the aorta using Adaptive Statistical Iterative Reconstruction (ASIR) and to determine if this has an effect on image quality.
MATERIALS AND METHODS: We retrospectively reviewed 31 CT angiography examinations of the thoracic and abdominal aorta performed with ASIR and 32 consecutive similar examinations performed without ASIR. Volume CT dose index (CTDI(vol)), dose-length product (DLP), aortic enhancement at multiple levels, aorta-to-muscle contrast-to-noise ratio at multiple levels, and subjective image quality were compared between the two groups.
RESULTS: The mean CTDI(vol) and DLP were significantly lower for the studies performed with ASIR versus studies without ASIR (15.6 vs 21.5 mGy, with an average difference of 5.8 mGy [95% CI 2.3-9.4 mGy] and 818 vs 1075 mGy × cm with an average difference of -257 mGy × cm [54-460 mGy × cm], respectively). Aortic enhancement, aortic signal-to-noise ratio, and aortic to muscle contrast-to-noise ratio were not different between the two groups. Subjectively, one reviewer preferred the non-ASIR images and one found the images equivalent. Both reviewers believed the images were of diagnostic quality.
CONCLUSION: A 29% decrease in CTDI(vol) and a 20% decrease in DLP were obtained in scans with ASIR compared with scans without ASIR, without a quantitative loss of image quality.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21343485     DOI: 10.2214/AJR.10.4573

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  23 in total

Review 1.  CT angiography in the diagnosis of cardiovascular disease: a transformation in cardiovascular CT practice.

Authors:  Zhonghua Sun; Mansour Al Moudi; Yan Cao
Journal:  Quant Imaging Med Surg       Date:  2014-10

2.  Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults.

Authors:  Gaurav S Desai; Raul N Uppot; Elaine W Yu; Avinash R Kambadakone; Dushyant V Sahani
Journal:  Eur Radiol       Date:  2012-04-19       Impact factor: 5.315

3.  The use of adaptive statistical iterative reconstruction in pediatric head CT: a feasibility study.

Authors:  G A Vorona; G Zuccoli; T Sutcavage; B L Clayton; R C Ceschin; A Panigrahy
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-24       Impact factor: 3.825

4.  The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique.

Authors:  Heejin Kwon; Jinhan Cho; Jongyeong Oh; Dongwon Kim; Junghyun Cho; Sanghyun Kim; Sangyun Lee; Jihyun Lee
Journal:  Br J Radiol       Date:  2015-08-03       Impact factor: 3.039

5.  Aortic CT angiography dose reduction: investigation of optimal noise index and iterative algorithm strength in combination with low kV.

Authors:  Osvaldo Rampado; Stefania Busso; Domenica Garabello; Ezio Marengo; Marco Valerio; Simona Capello; Simona Veglia; Ottavio Davini; Roberto Ropolo
Journal:  Radiol Med       Date:  2015-12-16       Impact factor: 3.469

6.  Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique.

Authors:  Masaki Katsura; Izuru Matsuda; Masaaki Akahane; Jiro Sato; Hiroyuki Akai; Koichiro Yasaka; Akira Kunimatsu; Kuni Ohtomo
Journal:  Eur Radiol       Date:  2012-04-27       Impact factor: 5.315

7.  Full Dose-Reduction Potential of Statistical Iterative Reconstruction for Head CT Protocols in a Predominantly Pediatric Population.

Authors:  A E Mirro; S L Brady; R A Kaufman
Journal:  AJNR Am J Neuroradiol       Date:  2016-04-07       Impact factor: 3.825

8.  128-slice CT angiography of the aorta without ECG-gating: efficacy of faster gantry rotation time and iterative reconstruction in terms of image quality and radiation dose.

Authors:  Vincenzo Russo; Monica Garattoni; Francesco Buia; Domenico Attinà; Luigi Lovato; Maurizio Zompatori
Journal:  Eur Radiol       Date:  2015-05-24       Impact factor: 5.315

9.  Iterative reconstruction in single-source dual-energy CT angiography: feasibility of low and ultra-low volume contrast medium protocols.

Authors:  Ping Hou; Xiangnan Feng; Jie Liu; Yue Zhou; Yaojun Jiang; Xiaochen Jiang; Jianbo Gao
Journal:  Br J Radiol       Date:  2017-06-23       Impact factor: 3.039

10.  High pitch, low voltage dual source CT pulmonary angiography: assessment of image quality and diagnostic acceptability with hybrid iterative reconstruction.

Authors:  Patrick D McLaughlin; T Liang; M Homiedan; L J Louis; T W O'Connell; Karl Krzymyk; S Nicolaou; J R Mayo
Journal:  Emerg Radiol       Date:  2014-07-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.