Literature DB >> 22618435

Triple rule-out acute chest pain evaluation using a 320-row-detector volume CT: a comparison of the wide-volume and helical modes.

Eun-Ju Kang1, Ki-Nam Lee, Dong Won Kim, Bo Sung Kim, Sunseob Choi, Byeong-Ho Park, Jong Young Oh.   

Abstract

The purpose of this study was to investigate the image quality and radiation dose of triple rule-out computed tomography (TROCT) using a 320-row-detector volume CT system to compare the wide-volume and helical modes of this CT system. Sixty-four patients with noncritical chest pain were allocated to one of 2 groups according to the type of CT examination mode used. Group 1 patients were examined using the wide-volume (non-spiral) mode and group 2 patients were examined using the 160-detector row helical mode, with the same contrast injection protocol in both methods [biphasic injection protocol; injection rate of 4 ml/s, median volume, 70 ml (range 65-100 ml)]. Attenuations of the pulmonary trunk, ascending aorta, and coronary arteries were measured in Hounsfield units; a subjective overall patient-based image quality score of 1-3 was awarded to each study. Effective doses, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Average effective dose was significantly lower in group 1 than group 2 (9.7 ± 5.1 vs. 16 ± 5.9 mSv, P < 0.001). The mean attenuation of the main pulmonary trunk was significantly higher in group 1 than group 2 (P = 0.04) and mean attenuations in other vessels were not significant different. SNR and CNR were not significantly different between the groups. The proportion of diagnostic image qualities for chest CT angiography (CTA) was similar between the groups (93.5 vs. 93.9 %). In coronary CTA, group 1 showed a higher proportion of diagnostic image qualities than group 2 (100 vs. 87.9 %). The use of wide-volume mode of 320-detector CT reduces the overall effective radiation dose and results in similar attenuation and image quality for TROCT as compared with the helical mode.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22618435     DOI: 10.1007/s10554-012-0072-y

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  14 in total

1.  Technique factors and image quality as functions of patient weight at abdominal CT.

Authors:  W Huda; E M Scalzetti; G Levin
Journal:  Radiology       Date:  2000-11       Impact factor: 11.105

2.  Image quality of noninvasive coronary angiography using multislice spiral computed tomography and electron-beam computed tomography: intraindividual comparison in an animal model.

Authors:  Alexander Lembcke; Till H Wiese; Joerg Schnorr; Susanne Wagner; Juergen Mews; Thomas J Kroencke; Christian N H Enzweiler; Bernd Hamm; Matthias Taupitz
Journal:  Invest Radiol       Date:  2004-06       Impact factor: 6.016

3.  Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: a comparative study.

Authors:  Gudrun M Feuchtner; Daniel Jodocy; Andrea Klauser; Bernhard Haberfellner; Iman Aglan; Alexander Spoeck; Stefan Hiehs; Peter Soegner; Werner Jaschke
Journal:  Eur J Radiol       Date:  2009-08-09       Impact factor: 3.528

4.  Low-dose triple-rule-out using 320-row-detector volume MDCT--less contrast medium and lower radiation exposure.

Authors:  Tahir Durmus; Patrik Rogalla; Alexander Lembcke; Matthias R Mühler; Bernd Hamm; Patrick A Hein
Journal:  Eur Radiol       Date:  2011-02-24       Impact factor: 5.315

5.  Saving dose in triple-rule-out computed tomography examination using a high-pitch dual spiral technique.

Authors:  Wieland H Sommer; Jan C Schenzle; Christoph R Becker; Konstantin Nikolaou; Anno Graser; Gisela Michalski; Klement Neumaier; Maximilian F Reiser; Thorsten R C Johnson
Journal:  Invest Radiol       Date:  2010-02       Impact factor: 6.016

6.  Influence of cardiac hemodynamic parameters on coronary artery opacification with 64-slice computed tomography.

Authors:  Lars Husmann; Hatem Alkadhi; Thomas Boehm; Sebastian Leschka; Tiziano Schepis; Pascal Koepfli; Lotus Desbiolles; Borut Marincek; Philipp A Kaufmann; Simon Wildermuth
Journal:  Eur Radiol       Date:  2006-01-28       Impact factor: 5.315

7.  Triple rule-out CT in patients with suspicion of acute pulmonary embolism: findings and accuracy.

Authors:  Thomas Schertler; Thomas Frauenfelder; Paul Stolzmann; Hans Scheffel; Lotus Desbiolles; Borut Marincek; Vladimir Kaplan; Nils Kucher; Hatem Alkadhi
Journal:  Acad Radiol       Date:  2009-06       Impact factor: 3.173

8.  Patients admitted to the emergency room with symptoms indicative of acute myocardial infarction.

Authors:  B W Karlson; J Herlitz; P Pettersson; H E Ekvall; A Hjalmarson
Journal:  J Intern Med       Date:  1991-09       Impact factor: 8.989

9.  Influence of heart rate on diagnostic accuracy and image quality of 16-slice CT coronary angiography: comparison of multisegment and halfscan reconstruction approaches.

Authors:  Marc Dewey; Florian Teige; Michael Laule; Bernd Hamm
Journal:  Eur Radiol       Date:  2007-07-17       Impact factor: 5.315

10.  Image quality in a low radiation exposure protocol for retrospectively ECG-gated coronary CT angiography.

Authors:  Tobias Pflederer; Larissa Rudofsky; Dieter Ropers; Sven Bachmann; Mohamed Marwan; Werner G Daniel; Stephan Achenbach
Journal:  AJR Am J Roentgenol       Date:  2009-04       Impact factor: 3.959

View more
  5 in total

1.  128-slice CT angiography of the aorta without ECG-gating: efficacy of faster gantry rotation time and iterative reconstruction in terms of image quality and radiation dose.

Authors:  Vincenzo Russo; Monica Garattoni; Francesco Buia; Domenico Attinà; Luigi Lovato; Maurizio Zompatori
Journal:  Eur Radiol       Date:  2015-05-24       Impact factor: 5.315

2.  [Possibilities for exposure reduction in computed tomography examination of acute chest pain].

Authors:  H-C Becker
Journal:  Radiologe       Date:  2012-10       Impact factor: 0.635

3.  Effect of iterative reconstruction techniques on image quality in low radiation dose chest CT: a phantom study.

Authors:  Yan Xu; Ting-Ting Zhang; Zhi-Hai Hu; Juan Li; Hong-Jun Hou; Zu-Shan Xu; Wen He
Journal:  Diagn Interv Radiol       Date:  2019-11       Impact factor: 2.630

4.  Dual-energy computed tomography of the neck-optimizing tube current settings and radiation dose using a 3D-printed patient phantom.

Authors:  Torsten Diekhoff; Michael Scheel; Wiebke Kress; Bernd Hamm; Paul Jahnke
Journal:  Quant Imaging Med Surg       Date:  2021-04

Review 5.  Clinical Applications of Wide-Detector CT Scanners for Cardiothoracic Imaging: An Update.

Authors:  Eun Ju Kang
Journal:  Korean J Radiol       Date:  2019-12       Impact factor: 3.500

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.