BACKGROUND: The diagnostic accuracy of 64-slice MDCT in comparison with IVUS has been poorly described and is mainly restricted to reports analyzing segments with documented atherosclerotic plaques.Entities:
Mesh:
Year: 2015 PMID: 25993595 PMCID: PMC4415868 DOI: 10.5935/abc.20140211
Source DB: PubMed Journal: Arq Bras Cardiol ISSN: 0066-782X Impact factor: 2.000
Figure 1Schematic representation of quantitative coronary analysis by 64-slice MDCT (above) and IVUS (below). The upper images show the longitudinal reconstruction for both methods. The lower images show illustrative vessel cross-sections with the outer vessel and lumen (inner) boundaries tracings.
Patients characteristics (n = 21)
| Age, years | 56.6 ± 9.5 |
| Male | 71.4 |
| Weight, kg | 69.2 ± 9.9 |
| Height, cm | 161.2 ± 7.3 |
| Diabetes | 47.6 |
| Hypertension | 71.4 |
| Previous myocardial infarction | 38.1 |
| Multivessel disease | 38.1 |
| Stable coronary disease | 52.3 |
| Total length of analyzed vessels, mm | 114.6 ± 38.3 |
| Imaged vessel (n = 70) | |
| Left main | 24.3 |
| Left anterior descending | 25.7 |
| Diagonal | 1.4 |
| Left circumflex | 22.9 |
| Obtuse marginal | 1.4 |
| Right coronary | 24.3 |
Numbers are mean ± standard deviation or percentage.
Quantitative coronary lumen parameters by IVUS and by 64-slice MDCT at patient, vessel, and segment levels
| Mean lumen area, mm2 | 8.6 ± 2.1 | 7.8 ± 2.3 | -0.7 ± 1.6 | 0.75 | < 0.001 |
| Minimal lumen area, mm2 | 3.3 ± 1.3 | 1.8 ± 1.9 | -1.5 ± 1.2 | 0.78 | < 0.001 |
| Minimal lumen diameter, mm | 1.8 ± 0.3 | 1.0 ± 0.6 | -0.8 ± 0.5 | 0.64 | 0.002 |
| Mean lumen area, mm2 | 10.1 ± 5.3 | 9.1 ± 4.8 | -1.0 ± 2.2 | 0.91 | < 0.001 |
| Minimal lumen area, mm2 | 6.9 ± 5.3 | 5.3 ± 4.9 | -1.5 ± 1.9 | 0.93 | < 0.001 |
| Minimal lumen diameter, mm | 2.5 ± 0.9 | 1.9 ± 1.0 | -0.6 ± 0.5 | 0.87 | < 0.001 |
| Mean lumen area, mm2 | 10.2 ± 5.2 | 9.1 ± 4.5 | -1.1 ± 2.3 | 0.89 | < 0.001 |
| Minimal lumen area, mm2 | 8.1 ± 4.6 | 6.8 ± 4.1 | -1.4 ± 2.3 | 0.87 | < 0.001 |
| Minimal lumen diameter, mm | 2.8 ± 0.8 | 2.4 ± 0.8 | -0.5 ± 0.5 | 0.78 | < 0.001 |
| Mean lumen area, mm2 | 7.1 ± 2.9 | 7.0 ± 3.3 | -0.1 ± 1.8 | 0.84 | < 0.001 |
| Minimal lumen area, mm2 | 5.1 ± 2.8 | 4.3 ± 3.3 | -0.9 ± 1.9 | 0.82 | < 0.001 |
| Minimal lumen diameter, mm | 2.2 ± 0.5 | 1.7 ± 0.8 | -0.5 ± 0.5 | 0.76 | < 0.001 |
Numbers are mean ± standard deviation.
IVUS: intravascular ultrasound; MDCT: multidetector computed tomography; PB: plaque burden
Figure 3Bland-Altman graphs for 64-slice MDCT and IVUS measurements at segment level. Mean lumen area (A), minimal lumen area (B), and minimal lumen diameter (C) for segments without significant plaques (IVUS plaque burden ≤ 40%; left) and for segments with atherosclerotic plaque (IVUS plaque burden > 40%; right). The solid lines represent the mean difference in measurements, and the traced lines represent the upper and lower 95% confidence intervals for the diference in measurements.
Figure 2Bland-Altman graphs for 64-slice MDCT and IVUS measurements at patient and vessel levels. Mean lumen area (A), minimal lumen area (B), and minimal lumen diameter (C) in per-patient (left) and per-vessel analyses (right). The solid lines represent the mean difference in measurements, and the traced lines represent the upper and lower 95% confidence intervals for the difference in measurements.
64-slice MDCT sensitivity, specificity, negative predictive value, positive predictive value, and global predictive accuracy * for the detection of luminal area < 4.0 mm2 and luminal diameter < 1.8 mm by IVUS †
| Prevalence | 86% | 67% |
| Sensitivity | 100% | 100% |
| Specificity | 33% | 29% |
| Negative predictive value | 100% | 100% |
| Positive predictive value | 90% | 73% |
| Global predictive accuracy | 0.82 | 0.74 |
| Prevalence | 44% | 24% |
| Sensitivity | 90% | 94% |
| Specificity | 69% | 27% |
| Negative predictive value | 70% | 97% |
| Positive predictive value | 70% | 41% |
| Global predictive accuracy | 0.90 | 0.90 |
| Prevalence | 14% | 6% |
| Sensitivity | 93% | 100% |
| Specificity | 83% | 77% |
| Negative predictive value | 99% | 100% |
| Positive predictive value | 48% | 22% |
| Global predictive accuracy | 0.92 | 0.89 |
| Prevalence | 49% | 21% |
| Sensitivity | 83% | 93% |
| Specificity | 69% | 49% |
| Negative predictive value | 81% | 97% |
| Positive predictive value | 73% | 33% |
| Global predictive accuracy | 0.87 | 0.89 |
IVUS: intravascular ultrasound; MDCT: multidetector computed tomography; PB: percent plaque burden
Global predictive accuracy calculated as the area under the receiver operating characteristic curve (C-index)
IVUS parameters previously shown to be associated with flow-limiting lesions.(3)