Literature DB >> 15750815

Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex vivo model of coronary computed tomography angiography.

Filippo Cademartiri1, Nico R Mollet, Giuseppe Runza, Nico Bruining, Ronald Hamers, Pamela Somers, Michiel Knaapen, Stefan Verheye, Massimo Midiri, Gabriel P Krestin, Pim J de Feyter.   

Abstract

Assessment of attenuation (measured in Hounsfield units, HU) of human coronary plaques was performed using multislice computed tomography (MSCT) in an ex vivo model. In three ex vivo specimens of left coronary arteries in oil, MSCT was performed after intracoronary injection of four solutions of contrast material (400 mgI/ml iomeprol). The four solutions were diluted as follows: 1/infinity, 1/200, 1/80, and 1/20. All scans were performed with the following parameters: slices/collimation 16/0.75 mm, rotation time 375 ms. Each specimen was scored for the presence of atherosclerotic plaques. In each plaque the attenuation was measured in four regions of interest for lumen, plaque (non-calcified thickening of the vessel wall), calcium, and surrounding (oil surrounding the vessel). The results were compared with a one-way analysis of variance test and were correlated with Pearson's test. There were no significant differences in the attenuation of calcium and oil in the four solutions. The mean attenuation in the four solutions for lumen (35+/-10, 91+/-7, 246+/-18, 511+/-89 HU) and plaque (22+/-22, 50+/-26, 107+/-36, 152+/-67 HU) was significantly different between each decreasing dilution (p<0.001). The mean attenuation of lumen and plaque of coronary plaques showed high correlation, while the values were significantly different (r=0.73; p<0.001). Intracoronary attenuation modifies significantly the attenuation of plaques assessed with MSCT.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15750815     DOI: 10.1007/s00330-005-2697-x

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  20 in total

1.  Quantitative measurements of in-stent restenosis: A comparison between quantitative coronary ultrasound and quantitative coronary angiography.

Authors:  N Bruining; M Sabate; P J de Feyter; I P Kay; J Ligthart; C Disco; M J Kutryk; J R Roelandt; P W Serruys
Journal:  Catheter Cardiovasc Interv       Date:  1999-10       Impact factor: 2.692

Review 2.  Lessons from sudden coronary death: a comprehensive morphological classification scheme for atherosclerotic lesions.

Authors:  R Virmani; F D Kolodgie; A P Burke; A Farb; S M Schwartz
Journal:  Arterioscler Thromb Vasc Biol       Date:  2000-05       Impact factor: 8.311

3.  Accuracy of density measurements within plaques located in artificial coronary arteries by X-ray multislice CT: results of a phantom study.

Authors:  S Schroeder; T Flohr; A F Kopp; C Meisner; A Kuettner; C Herdeg; A Baumbach; B Ohnesorge
Journal:  J Comput Assist Tomogr       Date:  2001 Nov-Dec       Impact factor: 1.826

4.  Composition of coronary atherosclerotic plaques in patients with acute myocardial infarction and stable angina pectoris determined by contrast-enhanced multislice computed tomography.

Authors:  Alexander W Leber; Andreas Knez; Carl W White; Alexander Becker; Franz von Ziegler; Olaf Muehling; Christoph Becker; Maximilian Reiser; Gerhard Steinbeck; Peter Boekstegers
Journal:  Am J Cardiol       Date:  2003-03-15       Impact factor: 2.778

5.  Multidetector-row computed tomography of the coronary arteries: predictive value and quantitative assessment of non-calcified vessel-wall changes.

Authors:  Konstantin Nikolaou; Sonja Sagmeister; Andreas Knez; Ernst Klotz; Bernd J Wintersperger; Christoph R Becker; Maximilian F Reiser
Journal:  Eur Radiol       Date:  2003-08-20       Impact factor: 5.315

6.  Improved procedural results of coronary angioplasty with intravascular ultrasound-guided balloon sizing: the CLOUT Pilot Trial. Clinical Outcomes With Ultrasound Trial (CLOUT) Investigators.

Authors:  G W Stone; J M Hodgson; F G St Goar; A Frey; H Mudra; H Sheehan; T J Linnemeier
Journal:  Circulation       Date:  1997-04-15       Impact factor: 29.690

7.  Reduction of restenosis by vessel size adapted percutaneous transluminal coronary angioplasty using intravascular ultrasound.

Authors:  S Schroeder; A Baumbach; K K Haase; M Oberhoff; H Marholdt; C Herdeg; A Athanasiadis; K R Karsch
Journal:  Am J Cardiol       Date:  1999-03-15       Impact factor: 2.778

8.  Serial in vivo MRI documents arterial remodeling in experimental atherosclerosis.

Authors:  S G Worthley; G Helft; V Fuster; A G Zaman; Z A Fayad; J T Fallon; J J Badimon
Journal:  Circulation       Date:  2000-02-15       Impact factor: 29.690

9.  Multidetector-row computed tomography and magnetic resonance imaging of atherosclerotic lesions in human ex vivo coronary arteries.

Authors:  Konstantin Nikolaou; Christoph R Becker; Michael Muders; Gregor Babaryka; Juergen Scheidler; Thomas Flohr; Udo Loehrs; Maximilian F Reiser; Zahi A Fayad
Journal:  Atherosclerosis       Date:  2004-06       Impact factor: 5.162

10.  Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT.

Authors:  Christoph R Becker; Konstantin Nikolaou; Michael Muders; Gregor Babaryka; Alexander Crispin; U Joseph Schoepf; Udo Loehrs; Maximilian F Reiser
Journal:  Eur Radiol       Date:  2003-04-12       Impact factor: 5.315

View more
  72 in total

1.  Assessment of atherosclerotic plaques in a rabbit model by delayed-phase contrast-enhanced CT angiography: comparison with histopathology.

Authors:  Jin Hur; Young Jin Kim; Hyo Sup Shim; Hye-Jeong Lee; Ji Eun Nam; Kyu Ok Choe; Byoung Wook Choi
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-30       Impact factor: 2.357

2.  Shorter delay time reduces interpatient variability in coronary enhancement in coronary CT angiography using the bolus tracking method with 320-row CT.

Authors:  Nobuo Tomizawa; Takeshi Nojo; Masaaki Akahane; Rumiko Torigoe; Shigeru Kiryu; Kuni Ohtomo
Journal:  Int J Cardiovasc Imaging       Date:  2012-04-22       Impact factor: 2.357

3.  Variability and accuracy of coronary CT angiography including use of iterative reconstruction algorithms for plaque burden assessment as compared with intravascular ultrasound-an ex vivo study.

Authors:  Paul Stolzmann; Christopher L Schlett; Pal Maurovich-Horvat; Akiko Maehara; Shixin Ma; Hans Scheffel; Leif-Christopher Engel; Mihály Károlyi; Gary S Mintz; Udo Hoffmann
Journal:  Eur Radiol       Date:  2012-05-24       Impact factor: 5.315

4.  Influence of statin treatment on coronary atherosclerosis visualised using multidetector computed tomography.

Authors:  Hans Hoffmann; Katja Frieler; Peter Schlattmann; Bernd Hamm; Marc Dewey
Journal:  Eur Radiol       Date:  2010-07-18       Impact factor: 5.315

5.  Plaque imaging with CT coronary angiography: Effect of intra-vascular attenuation on plaque type classification.

Authors:  Erica Maffei; Chiara Martini; Teresa Arcadi; Alberto Clemente; Sara Seitun; Alessandra Zuccarelli; Tito Torri; Nico R Mollet; Alexia Rossi; Onofrio Catalano; Giancarlo Messalli; Filippo Cademartiri
Journal:  World J Radiol       Date:  2012-06-28

6.  Optimal boundary detection method and window settings for coronary atherosclerotic plaque volume analysis in coronary computed tomography angiography: comparison with intravascular ultrasound.

Authors:  Ran Heo; Hyung-Bok Park; Byoung Kwon Lee; Sanghoon Shin; Reza Arsanjani; James K Min; Hyuk-Jae Chang
Journal:  Eur Radiol       Date:  2015-12-02       Impact factor: 5.315

Review 7.  MDCT evaluation of atherosclerotic coronary artery disease: what should radiologists know?

Authors:  Hye Rin Kim; Seung Min Yoo; Ji Young Rho; Hwa Yeon Lee; Charles S White
Journal:  Int J Cardiovasc Imaging       Date:  2014-04-01       Impact factor: 2.357

Review 8.  A practical guide to reading CT coronary angiograms--how to avoid mistakes when assessing for coronary stenoses.

Authors:  John W M Hoe; Kok Hong Toh
Journal:  Int J Cardiovasc Imaging       Date:  2006-12-21       Impact factor: 2.357

Review 9.  Comprehensive cardiac CT study: evaluation of coronary arteries, left ventricular function, and myocardial perfusion--is it possible?

Authors:  Ricardo C Cury; Koen Nieman; Michael D Shapiro; Khurram Nasir; Roberto C Cury; Thomas J Brady
Journal:  J Nucl Cardiol       Date:  2007-04       Impact factor: 5.952

10.  Fabrication and control of CT number through polymeric composites based on coronary plaque CT phantom applications.

Authors:  Carlton F O Hoy; Hani E Naguib; Narinder Paul
Journal:  J Med Imaging (Bellingham)       Date:  2016-02-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.