Literature DB >> 25854215

Typical exposure parameters, organ doses and effective doses for endovascular aortic aneurysm repair: Comparison of Monte Carlo simulations and direct measurements with an anthropomorphic phantom.

Monika Foerth1, Michael C Seidenbusch, Mojtaba Sadeghi-Azandaryani, Ursula Lechel, Karla Maria Treitl, Marcus Treitl.   

Abstract

OBJECTIVES: Radiation exposure of patients during endovascular aneurysm repair (EVAR) procedures ranks in the upper sector of medical exposure. Thus, estimation of radiation doses achieved during EVAR is of great importance.
MATERIAL AND METHODS: Organ doses (OD) and effective doses (ED) administered to 17 patients receiving EVAR were determined (1) from the exposure parameters by performing Monte Carlo simulations in mathematical phantoms and (2) by measurements with thermoluminescent dosimeters in a physical anthropomorphic phantom.
RESULTS: The mean fluoroscopy time was 26 min, the mean dose area product was 24995 cGy cm2. The mean ED was 34.8 mSv, ODs up to 626 mSv were found. Whereas digital subtraction angiographies (DSA) and fluoroscopies each contributed about 50% to the cumulative ED, the ED rates of DSAs were found to be ten times higher than those of fluoroscopies. Doubling of the field size caused an ED rate enhancement up to a factor of 3.
CONCLUSION: EVAR procedures cause high radiation exposure levels that exceed the values published thus far. As a consequence, (1) DSAs should be only performed when necessary and with a low image rate, (2) fluoroscopies should be kept as short as possible, and (3) field sizes should be minimized. KEY POINTS: • During endovascular aneurysm repair (EVAR) considerable patient doses are achieved. • For each EVAR procedure organ (OD) and effective (ED) doses were determined. • The mean ED was 34.8 mSv, the highest OD was 626 mSv. • Number of DSAs, fluoroscopy durations and field sizes should be minimized.

Entities:  

Mesh:

Year:  2015        PMID: 25854215     DOI: 10.1007/s00330-015-3673-8

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  19 in total

Review 1.  Radiation dermatitis: clinical presentation, pathophysiology, and treatment 2006.

Authors:  Sharon R Hymes; Eric A Strom; Caroline Fife
Journal:  J Am Acad Dermatol       Date:  2006-01       Impact factor: 11.527

2.  The impact of radiation dose exposure during endovascular aneurysm repair on patient safety.

Authors:  Claire Jones; Stephen A Badger; Christopher S Boyd; Chee V Soong
Journal:  J Vasc Surg       Date:  2010-08       Impact factor: 4.268

3.  Computation of bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detector.

Authors:  R Birch; M Marshall
Journal:  Phys Med Biol       Date:  1979-05       Impact factor: 3.609

4.  Measurement and optimization of patient radiation doses in endovascular aneurysm repair.

Authors:  C Walsh; A O'Callaghan; D Moore; S O'Neill; P Madhavan; M P Colgan; S N Haider; A O'Reilly; G O'Reilly
Journal:  Eur J Vasc Endovasc Surg       Date:  2012-02-16       Impact factor: 7.069

5.  Radiation exposure to patients and radiologists during interventional procedures.

Authors:  E Molyvda-Athanasopoulou; M Karlatira; A Gotzamani-Psarrakou; Ch Koulouris; A Siountas
Journal:  Radiat Prot Dosimetry       Date:  2011-07-15       Impact factor: 0.972

6.  The impact of radiological equipment on patient radiation exposure during endovascular aortic aneurysm repair.

Authors:  Rita Fossaceca; Marco Brambilla; Giuseppe Guzzardi; Paolo Cerini; Alessandra Renghi; Serena Valzano; Piero Brustia; Alessandro Carriero
Journal:  Eur Radiol       Date:  2012-05-23       Impact factor: 5.315

7.  A comparison of newborn stylized and tomographic models for dose assessment in paediatric radiology.

Authors:  R J Staton; F D Pazik; J C Nipper; J L Williams; W E Bolch
Journal:  Phys Med Biol       Date:  2003-04-07       Impact factor: 3.609

8.  Radiation burden of patients undergoing endovascular abdominal aortic aneurysm repair.

Authors:  John A Kalef-Ezra; Stratos Karavasilis; Dimosthenis Ziogas; Dimitris Dristiliaris; Lampros K Michalis; Miltiadis Matsagas
Journal:  J Vasc Surg       Date:  2009-02       Impact factor: 4.268

Review 9.  Fluoroscopically guided interventional procedures: a review of radiation effects on patients' skin and hair.

Authors:  Stephen Balter; John W Hopewell; Donald L Miller; Louis K Wagner; Michael J Zelefsky
Journal:  Radiology       Date:  2010-02       Impact factor: 11.105

10.  Radiation exposure during endovascular aneurysm repair.

Authors:  R A Weerakkody; S R Walsh; C Cousins; K E Goldstone; T Y Tang; M E Gaunt
Journal:  Br J Surg       Date:  2008-06       Impact factor: 6.939

View more
  4 in total

1.  Patient dose in interventional radiology: a multicentre study of the most frequent procedures in France.

Authors:  Cécile Etard; Emeline Bigand; Cécile Salvat; Vincent Vidal; Jean Paul Beregi; Amaury Hornbeck; Joël Greffier
Journal:  Eur Radiol       Date:  2017-03-13       Impact factor: 5.315

2.  Investigation of reference levels and radiation dose associated with abdominal EVAR (endovascular aneurysm repair) procedures across several European Centres.

Authors:  E Tuthill; L O'Hora; M O'Donohoe; S Panci; P Gilligan; D Campion; R Trenti; E Fox; D Catania; L Rainford
Journal:  Eur Radiol       Date:  2017-05-18       Impact factor: 5.315

3.  Breast dose reduction for chest CT by modifying the scanning parameters based on the pre-scan size-specific dose estimate (SSDE).

Authors:  Masafumi Kidoh; Daisuke Utsunomiya; Seitaro Oda; Takeshi Nakaura; Yoshinori Funama; Hideaki Yuki; Kenichiro Hirata; Tomohiro Namimoto; Daisuke Sakabe; Masahiro Hatemura; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2016-10-07       Impact factor: 5.315

4.  A national dose analysis of guided tumor destruction: influence of sex, age, localization and destruction technique used.

Authors:  Matthieu Rojo; Aymeric Hamard; Chris Serrand; Hélène de Forges; Jean-Paul Beregi; Joël Greffier; Julien Frandon
Journal:  Quant Imaging Med Surg       Date:  2022-03
  4 in total