Literature DB >> 20093507

Fluoroscopically guided interventional procedures: a review of radiation effects on patients' skin and hair.

Stephen Balter1, John W Hopewell, Donald L Miller, Louis K Wagner, Michael J Zelefsky.   

Abstract

Most advice currently available with regard to fluoroscopic skin reactions is based on a table published in 1994. Many caveats in that report were not included in later reproductions, and subsequent research has yielded additional insights. This review is a consensus report of current scientific data. Expected skin reactions for an average patient are presented in tabular form as a function of peak skin dose and time after irradiation. The text and table indicate the variability of reactions in different patients. Images of injuries to skin and underlying tissues in patients and animals are provided and are categorized according to the National Cancer Institute skin toxicity scale, offering a basis for describing cutaneous radiation reactions in interventional fluoroscopy and quantifying their clinical severity. For a single procedure performed in most individuals, noticeable skin changes are observed approximately 1 month after a peak skin dose exceeding several grays. The degree of injury to skin and subcutaneous tissue increases with dose. Specialized wound care may be needed when irradiation exceeds 10 Gy. Residual effects from radiation therapy and from previous procedures influence the response of skin and subcutaneous tissues to subsequent procedures. Skin irradiated to a dose higher than 3-5 Gy often looks normal but reacts abnormally when irradiation is repeated. If the same area of skin is likely to be exposed to levels higher than a few grays, the effects of previous irradiation should be included when estimating the expected tissue reaction from the additional procedure. (c) RSNA, 2010.

Entities:  

Mesh:

Year:  2010        PMID: 20093507     DOI: 10.1148/radiol.2542082312

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  105 in total

1.  Skin dose mapping for fluoroscopically guided interventions.

Authors:  Perry B Johnson; David Borrego; Stephen Balter; Kevin Johnson; Daniel Siragusa; Wesley E Bolch
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

Review 2.  Fluoroscopic sentinel events in neuroendovascular procedures: how to screen, prevent, and address occurrence.

Authors:  A Z Vance; B D Weinberg; G M Arbique; J B Guild; J A Anderson; D P Chason
Journal:  AJNR Am J Neuroradiol       Date:  2012-07-05       Impact factor: 3.825

Review 3.  Effects of radiation exposure from cardiac imaging: how good are the data?

Authors:  Andrew J Einstein
Journal:  J Am Coll Cardiol       Date:  2012-02-07       Impact factor: 24.094

Review 4.  Cancer risks associated with external radiation from diagnostic imaging procedures.

Authors:  Martha S Linet; Thomas L Slovis; Donald L Miller; Ruth Kleinerman; Choonsik Lee; Preetha Rajaraman; Amy Berrington de Gonzalez
Journal:  CA Cancer J Clin       Date:  2012-02-03       Impact factor: 508.702

5.  Radiation exposure and safety practices during pediatric central line placement.

Authors:  Melody R Saeman; Lorrie S Burkhalter; Timothy J Blackburn; Joseph T Murphy
Journal:  J Pediatr Surg       Date:  2015-03-19       Impact factor: 2.545

6.  Experimental estimates of peak skin dose and its relationship to the CT dose index using the CTDI head phantom.

Authors:  Hugo de las Heras; Ronaldo Minniti; Sean Wilson; Chad Mitchell; Marlene Skopec; Claudia C Brunner; Kish Chakrabarti
Journal:  Radiat Prot Dosimetry       Date:  2013-07-16       Impact factor: 0.972

7.  Monte Carlo investigation of backscatter point spread function for X-ray imaging examinations.

Authors:  Zhenyu Xiong; Sarath Vijayan; Stephen Rudin; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09

8.  Real-time eye lens dose monitoring during cerebral angiography procedures.

Authors:  M J Safari; J H D Wong; K A A Kadir; N K Thorpe; D L Cutajar; M Petasecca; M L F Lerch; A B Rosenfeld; K H Ng
Journal:  Eur Radiol       Date:  2015-05-23       Impact factor: 5.315

9.  Square alopecia: a new type of transient alopecia of the scalp following fluoroscopically endovascular embolization.

Authors:  Sebastian Podlipnik; Priscila Giavedoni; Luis San-Román; Juan Ferrando
Journal:  Int J Trichology       Date:  2013-10

10.  Calculation of Forward Scatter Dose Distribution at the skin entrance from the patient table for fluoroscopically guided interventions using a pencil beam convolution kernel.

Authors:  Sarath Vijayan; Zhenyu Xiong; Chao Guo; Jonathan Troville; Naveed Islam; Stephen Rudin; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-09
View more