Literature DB >> 22342015

Measurement and optimization of patient radiation doses in endovascular aneurysm repair.

C Walsh1, A O'Callaghan, D Moore, S O'Neill, P Madhavan, M P Colgan, S N Haider, A O'Reilly, G O'Reilly.   

Abstract

The study assessed radiation exposure during EVAR. Two types of patient dose were estimated: effective dose (ED), which allows estimation of radiation risk to the EVAR patient population; and Peak Skin Dose (PSD), which allows us assess the potential for an individual patient to receive a radiation skin injury. An ancillary aim was to examine dose optimization in EVAR procedures. Based on 111 EVAR cases we estimated average ED as 12.4 mSv. Cumulative patient dose in our centre was lower than other studies because the follow up of EVAR patients is based on ultrasound rather than CT. PSD calculated using a published conversion formula closely matched measurements with calibrated gafchromic film. 99% of patients had an estimated PSD of < 2Gy. Results indicate that skin injuries are possible, but very unlikely in EVAR procedures at our centre. EVAR is a high dose procedure and emphasis on dose optimisation is important. We broke the EVAR procedure into 15 steps and, in a phantom study, showed how skin dose changes as procedure steps are varied. The resulting dose matrix has the potential to be used as an educational tool to promote dose optimization.
Copyright © 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22342015     DOI: 10.1016/j.ejvs.2012.01.028

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  3 in total

1.  Typical exposure parameters, organ doses and effective doses for endovascular aortic aneurysm repair: Comparison of Monte Carlo simulations and direct measurements with an anthropomorphic phantom.

Authors:  Monika Foerth; Michael C Seidenbusch; Mojtaba Sadeghi-Azandaryani; Ursula Lechel; Karla Maria Treitl; Marcus Treitl
Journal:  Eur Radiol       Date:  2015-04-09       Impact factor: 5.315

2.  Investigation of reference levels and radiation dose associated with abdominal EVAR (endovascular aneurysm repair) procedures across several European Centres.

Authors:  E Tuthill; L O'Hora; M O'Donohoe; S Panci; P Gilligan; D Campion; R Trenti; E Fox; D Catania; L Rainford
Journal:  Eur Radiol       Date:  2017-05-18       Impact factor: 5.315

3.  Incidental extravascular findings in computed tomographic angiography for planning or monitoring endovascular aortic aneurysm repair: Smoker patients, increased lung cancer prevalence?

Authors:  Maria Antonietta Mazzei; Susanna Guerrini; Francesco Gentili; Giuseppe Galzerano; Francesco Setacci; Domenico Benevento; Francesco Giuseppe Mazzei; Luca Volterrani; Carlo Setacci
Journal:  World J Radiol       Date:  2017-07-28
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.