Literature DB >> 20670773

The impact of radiation dose exposure during endovascular aneurysm repair on patient safety.

Claire Jones1, Stephen A Badger, Christopher S Boyd, Chee V Soong.   

Abstract

OBJECTIVE: Endovascular aneurysm repair (EVAR) exposes patients to radiation during the procedure and in subsequent follow-up. The study goal was to calculate the radiation dose in our unit and compare it against other published data and national guidelines.
METHODS: All EVAR procedures were identified from a prospectively maintained database. Radiation dose, screening time, and volume of intravenous contrast during the procedure were reviewed. Radiation exposure from subsequent computed tomography (CT) imaging was included in the overall exposure. Results are expressed as mean +/- standard deviation.
RESULTS: From October 1998 to October 2008, 320 elective patients underwent EVAR. Mean screening time was 29.4 +/- 23.3 minutes, and the radiation dose was 11.7 +/- 7.1 mSv. The EVAR was an emergency in 64 patients. The mean screening time was 22.9 +/- 18.2 minutes, and the radiation dose was 13.4 +/- 8.6 mSv. During the first postoperative year, follow-up CT scans exposed the patients to 24.0 mSv, with 8.0 mSv in subsequent years. Abdominal radiographs added an additional 1.8 mSv each year.
CONCLUSION: EVAR and the follow-up investigations involve substantial amounts of radiation, with well-recognized carcinogenic risks. Because patient safety is paramount, radiation exposure should be minimized. This may be possible by standardizing radiation exposure throughout the United Kingdom by implementing national guidelines and considering other imaging modalities for follow-up. Copyright (c) 2010. Published by Mosby, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20670773     DOI: 10.1016/j.jvs.2010.03.004

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  11 in total

1.  Spontaneous type B aortic dissection in antepartum gemellary pregnancy and endovascular repair.

Authors:  Xudong Gu; Hongmei Liu; Yusheng Li; Libo Fei; Danbing Shao; Jianhua Mao; Shinan Nie
Journal:  Int J Clin Exp Med       Date:  2014-11-15

2.  Endovascular repair of abdominal aortic aneurysm does not improve early survival versus open repair in patients younger than 60 years.

Authors:  P K Gupta; B Ramanan; T G Lynch; H Gupta; X Fang; M Balters; J M Johanning; G M Longo; J N MacTaggart; I I Pipinos
Journal:  Eur J Vasc Endovasc Surg       Date:  2012-03-03       Impact factor: 7.069

3.  Electromagnetic navigation versus fluoroscopy in aortic endovascular procedures: a phantom study.

Authors:  Kjetil Tystad Lund; Geir Arne Tangen; Frode Manstad-Hulaas
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-08-04       Impact factor: 2.924

Review 4.  Physician and Patient Radiation Exposure During Endovascular Procedures.

Authors:  Andrew M Goldsweig; J Dawn Abbott; Herbert D Aronow
Journal:  Curr Treat Options Cardiovasc Med       Date:  2017-02

5.  Typical exposure parameters, organ doses and effective doses for endovascular aortic aneurysm repair: Comparison of Monte Carlo simulations and direct measurements with an anthropomorphic phantom.

Authors:  Monika Foerth; Michael C Seidenbusch; Mojtaba Sadeghi-Azandaryani; Ursula Lechel; Karla Maria Treitl; Marcus Treitl
Journal:  Eur Radiol       Date:  2015-04-09       Impact factor: 5.315

6.  The impact of radiological equipment on patient radiation exposure during endovascular aortic aneurysm repair.

Authors:  Rita Fossaceca; Marco Brambilla; Giuseppe Guzzardi; Paolo Cerini; Alessandra Renghi; Serena Valzano; Piero Brustia; Alessandro Carriero
Journal:  Eur Radiol       Date:  2012-05-23       Impact factor: 5.315

7.  Investigation of reference levels and radiation dose associated with abdominal EVAR (endovascular aneurysm repair) procedures across several European Centres.

Authors:  E Tuthill; L O'Hora; M O'Donohoe; S Panci; P Gilligan; D Campion; R Trenti; E Fox; D Catania; L Rainford
Journal:  Eur Radiol       Date:  2017-05-18       Impact factor: 5.315

8.  Cumulative radiation dose and radiation risk from medical imaging in patients subjected to endovascular aortic aneurysm repair.

Authors:  Marco Brambilla; Paolo Cerini; Domenico Lizio; Luca Vigna; Alessandro Carriero; Rita Fossaceca
Journal:  Radiol Med       Date:  2015-01-09       Impact factor: 3.469

9.  Identification of Factors Influencing Cumulative Long-Term Radiation Exposure in Patients Undergoing EVAR.

Authors:  G Kalender; Milan Lisy; U A Stock; A Endisch; A Kornberger
Journal:  Int J Vasc Med       Date:  2017-11-09

10.  Radiation - friend or foe? Presidential address to Ulster Medical Society 4th October 2012.

Authors:  Roy Spence
Journal:  Ulster Med J       Date:  2014-09
View more