Literature DB >> 25773935

A comparative study for image quality and radiation dose of a cone beam computed tomography scanner and a multislice computed tomography scanner for paranasal sinus imaging.

Jens De Cock1, Federica Zanca, John Canning, Ruben Pauwels, Robert Hermans.   

Abstract

OBJECTIVES: To evaluate image quality and radiation dose of a state of the art cone beam computed tomography (CBCT) system and a multislice computed tomography (MSCT) system in patients with sinonasal poliposis.
METHODS: In this retrospective study two radiologists evaluated 57 patients with sinonasal poliposis who underwent a CBCT or MSCT sinus examination, along with a control group of 90 patients with normal radiological findings. Tissue doses were measured using a phantom model with thermoluminescent dosimeters (TLD).
RESULTS: Overall image quality in CBCT was scored significantly higher than in MSCT in patients with normal radiologic findings (p-value: 0.00001). In patients with sinonasal poliposis, MSCT scored significantly higher than CBCT (p-value: 0.00001). The average effective dose for MSCT was 42% higher compared to CBCT (108 μSv vs 63 μSv).
CONCLUSIONS: CBCT and MSCT are both suited for the evaluation of sinonasal poliposis. In patients with sinonasal poliposis, clinically important structures of the paranasal sinuses can be better delineated with MSCT, whereas in patients without sinonasal poliposis, CBCT turns out to define the important structures of the sinonasal region better. However, given the lower radiation dose, CBCT can be considered for the evaluation of the sinonasal structures in patients with sinonasal poliposis. KEY POINTS: • CBCT and MSCT are both suited for evaluation of sinonasal poliposis. • Effective dose for MSCT was 42% higher compared to CBCT. • In patients with sinonasal poliposis, clinically important anatomical structures are better delineated with MSCT. • In patients with normal radiological findings, clinically important anatomical structures are better delineated with CBCT.

Entities:  

Mesh:

Year:  2015        PMID: 25773935     DOI: 10.1007/s00330-015-3593-7

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  24 in total

1.  Evaluation of subjective image quality in relation to diagnostic task for cone beam computed tomography with different fields of view.

Authors:  Sara Lofthag-Hansen; Anne Thilander-Klang; Kerstin Gröndahl
Journal:  Eur J Radiol       Date:  2010-10-20       Impact factor: 3.528

2.  Beam hardening artefacts occur in dental implant scans with the NewTom cone beam CT but not with the dental 4-row multidetector CT.

Authors:  F G Draenert; E Coppenrath; P Herzog; S Müller; U G Mueller-Lisse
Journal:  Dentomaxillofac Radiol       Date:  2007-05       Impact factor: 2.419

3.  Effective dose from cone beam CT examinations in dentistry.

Authors:  J A Roberts; N A Drage; J Davies; D W Thomas
Journal:  Br J Radiol       Date:  2008-10-13       Impact factor: 3.039

4.  Morphologic examination of the temporal bone by cone beam computed tomography: comparison with multislice helical computed tomography.

Authors:  M Dahmani-Causse; M Marx; O Deguine; B Fraysse; B Lepage; B Escudé
Journal:  Eur Ann Otorhinolaryngol Head Neck Dis       Date:  2011-10-19       Impact factor: 2.080

5.  Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners.

Authors:  A Suomalainen; T Kiljunen; Y Käser; J Peltola; M Kortesniemi
Journal:  Dentomaxillofac Radiol       Date:  2009-09       Impact factor: 2.419

6.  Use of intraoperative CT scanning in endoscopic sinus surgery: a preliminary report.

Authors:  Alexis H Jackman; James N Palmer; Alexander G Chiu; David W Kennedy
Journal:  Am J Rhinol       Date:  2008 Mar-Apr

7.  A comparative study for spatial resolution and subjective image characteristics of a multi-slice CT and a cone-beam CT for dental use.

Authors:  Hiroshi Watanabe; Eiichi Honda; Akemi Tetsumura; Tohru Kurabayashi
Journal:  Eur J Radiol       Date:  2009-10-09       Impact factor: 3.528

8.  EPOS 2012: European position paper on rhinosinusitis and nasal polyps 2012. A summary for otorhinolaryngologists.

Authors:  Wytske J Fokkens; Valerie J Lund; Joachim Mullol; Claus Bachert; Isam Alobid; Fuad Baroody; Noam Cohen; Anders Cervin; Richard Douglas; Philippe Gevaert; Christos Georgalas; Herman Goossens; Richard Harvey; Peter Hellings; Claire Hopkins; Nick Jones; Guy Joos; Livije Kalogjera; Bob Kern; Marek Kowalski; David Price; Herbert Riechelmann; Rodney Schlosser; Brent Senior; Mike Thomas; Elina Toskala; Richard Voegels; De Yun Wang; Peter John Wormald
Journal:  Rhinology       Date:  2012-03       Impact factor: 3.681

9.  Bilateral sinonasal polyposis in a patient with unilateral choanal atresia.

Authors:  Brian Lee; Nimish Patel; Berrylin J Ferguson
Journal:  Laryngoscope       Date:  2012-09-10       Impact factor: 3.325

10.  Categorizing nasal polyps by severity and controller therapy.

Authors:  Habib G Rizk; Berrylin J Ferguson
Journal:  Arch Otolaryngol Head Neck Surg       Date:  2012-09
View more
  8 in total

1.  Nasal endoscopy: an adjunct to patient selection for preoperative low-dose CT examination in chronic rhinosinusitis.

Authors:  Marcin Fraczek; Maciej Guzinski; Monika Morawska-Kochman; Kamil H Nelke; Tomasz Krecicki
Journal:  Dentomaxillofac Radiol       Date:  2016-10-17       Impact factor: 2.419

2.  Imaging re-evaluation of the tympanic segment of the facial nerve canal using cone-beam computed tomography compared with multi-slice computed tomography.

Authors:  Zhengyu Zhang; Hongxia Yin; Zheng Wang; Jing Li; Han Lv; Pengfei Zhao; Zhenghan Yang; Zhenchang Wang
Journal:  Eur Arch Otorhinolaryngol       Date:  2019-05-02       Impact factor: 2.503

3.  Analysis of the priority of anatomic structures according to the diagnostic task in cone-beam computed tomographic images.

Authors:  Jin-Woo Choi
Journal:  Imaging Sci Dent       Date:  2016-12-20

4.  Diagnostic usefulness of cone-beam computed tomography versus multi-detector computed tomography for sinonasal structure evaluation.

Authors:  Miran Han; Hyun Jun Kim; Jin Wook Choi; Do-Yang Park; Jang Gyu Han
Journal:  Laryngoscope Investig Otolaryngol       Date:  2022-03-30

5.  Visualisation of passive middle ear implants by cone beam and multi-detector computed tomography: a comparative in vitro study.

Authors:  T D Nguyen; S Kösling; R Mlynski; S K Plontke
Journal:  Eur Radiol       Date:  2016-03-30       Impact factor: 5.315

6.  Reduction of Radiation Dosage in Visualization of Paranasal Sinuses in Daily Routine.

Authors:  Christian Güldner; Isabell Diogo; Julia Leicht; Magis Mandapathil; Thomas Wilhelm; Afshin Teymoortash; Evelyn Jahns
Journal:  Int J Otolaryngol       Date:  2017-01-31

7.  A reject analysis of cone-beam CTs in under-aged patients.

Authors:  Jakob W G Van Acker; Wolfgang Jacquet; Melissa Dierens; Luc C Martens
Journal:  Dentomaxillofac Radiol       Date:  2019-01-11       Impact factor: 2.419

8.  Evaluation of symptomatic maxillary sinus pathologies using panoramic radiography and cone beam computed tomography-influence of professional training.

Authors:  Michael Dau; Paul Marciak; Bial Al-Nawas; Henning Staedt; Abdulmonem Alshiri; Bernhard Frerich; Peer Wolfgang Kämmerer
Journal:  Int J Implant Dent       Date:  2017-04-05
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.