Literature DB >> 20965675

Evaluation of subjective image quality in relation to diagnostic task for cone beam computed tomography with different fields of view.

Sara Lofthag-Hansen1, Anne Thilander-Klang, Kerstin Gröndahl.   

Abstract

AIMS: To evaluate subjective image quality for two diagnostic tasks, periapical diagnosis and implant planning, for cone beam computed tomography (CBCT) using different exposure parameters and fields of view (FOVs).
MATERIALS AND METHODS: Examinations were performed in posterior part of the jaws on a skull phantom with 3D Accuitomo (FOV 3 cm×4 cm) and 3D Accuitomo FPD (FOVs 4 cm×4 cm and 6 cm×6 cm). All combinations of 60, 65, 70, 75, 80 kV and 2, 4, 6, 8, 10 mA with a rotation of 180° and 360° were used. Dose-area product (DAP) value was determined for each combination. The images were presented, displaying the object in axial, cross-sectional and sagittal views, without scanning data in a random order for each FOV and jaw. Seven observers assessed image quality on a six-point rating scale.
RESULTS: Intra-observer agreement was good (κw=0.76) and inter-observer agreement moderate (κw=0.52). Stepwise logistic regression showed kV, mA and diagnostic task to be the most important variables. Periapical diagnosis, regardless jaw, required higher exposure parameters compared to implant planning. Implant planning in the lower jaw required higher exposure parameters compared to upper jaw. Overall ranking of FOVs gave 4 cm×4 cm, 6 cm×6 cm followed by 3 cm×4 cm.
CONCLUSIONS: This study has shown that exposure parameters should be adjusted according to diagnostic task. For this particular CBCT brand a rotation of 180° gave good subjective image quality, hence a substantial dose reduction can be achieved without loss of diagnostic information.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20965675     DOI: 10.1016/j.ejrad.2010.09.018

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  26 in total

1.  Development of a low-dose protocol for cone beam CT examinations of the anterior maxilla in children.

Authors:  Jose A Hidalgo Rivas; Keith Horner; Badri Thiruvenkatachari; Jonathan Davies; Chrysoula Theodorakou
Journal:  Br J Radiol       Date:  2015-08-17       Impact factor: 3.039

2.  Cone beam CT: a current overview of devices.

Authors:  A Nemtoi; C Czink; D Haba; A Gahleitner
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

3.  3D dento-maxillary osteolytic lesion and active contour segmentation pilot study in CBCT: semi-automatic vs manual methods.

Authors:  K Vallaeys; A Kacem; H Legoux; M Le Tenier; C Hamitouche; R Arbab-Chirani
Journal:  Dentomaxillofac Radiol       Date:  2015-05-21       Impact factor: 2.419

Review 4.  Effective dose of cone beam CT (CBCT) of the facial skeleton: a systematic review.

Authors:  A Al-Okshi; C Lindh; H Salé; M Gunnarsson; M Rohlin
Journal:  Br J Radiol       Date:  2015-01       Impact factor: 3.039

5.  Evaluation of the effective dose of cone beam CT and multislice CT for temporomandibular joint examinations at optimized exposure levels.

Authors:  N Kadesjö; D Benchimol; B Falahat; K Näsström; X-Q Shi
Journal:  Dentomaxillofac Radiol       Date:  2015-06-02       Impact factor: 2.419

6.  Influence of the artefact reduction algorithm of Picasso Trio CBCT system on the diagnosis of vertical root fractures in teeth with metal posts.

Authors:  I S Q Bezerra; F S Neves; T V Vasconcelos; G M B Ambrosano; D Q Freitas
Journal:  Dentomaxillofac Radiol       Date:  2015-03-12       Impact factor: 2.419

7.  A comparative study for image quality and radiation dose of a cone beam computed tomography scanner and a multislice computed tomography scanner for paranasal sinus imaging.

Authors:  Jens De Cock; Federica Zanca; John Canning; Ruben Pauwels; Robert Hermans
Journal:  Eur Radiol       Date:  2015-03-15       Impact factor: 5.315

8.  Dose optimization for assessment of periodontal structures in cone beam CT examinations.

Authors:  Ayman Al-Okshi; Chrysoula Theodorakou; Christina Lindh
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

9.  Impact of prone, supine and oblique patient positioning on CBCT image quality, contrast-to-noise ratio and figure of merit value in the maxillofacial region.

Authors:  Juha Koivisto; Maureen van Eijnatten; Jorma Järnstedt; Kirsi Holli-Helenius; Prasun Dastidar; Jan Wolff
Journal:  Dentomaxillofac Radiol       Date:  2017-04-07       Impact factor: 2.419

10.  Determination of optimum exposure parameters for dentoalveolar structures of the jaws using the CB MercuRay system with cluster signal-to-noise analysis.

Authors:  Warangkana Weerawanich; Mayumi Shimizu; Yohei Takeshita; Kazutoshi Okamura; Shoko Yoshida; Gainer R Jasa; Kazunori Yoshiura
Journal:  Oral Radiol       Date:  2018-09-14       Impact factor: 1.852

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.