Literature DB >> 19819091

A comparative study for spatial resolution and subjective image characteristics of a multi-slice CT and a cone-beam CT for dental use.

Hiroshi Watanabe1, Eiichi Honda, Akemi Tetsumura, Tohru Kurabayashi.   

Abstract

PURPOSE: Multi-slice CT (MSCT) and cone-beam CT (CBCT) are widely used in dental practice. This study compared the spatial resolution of these CT systems to elucidate which CT modalities should be selected for various clinical cases.
MATERIALS AND METHODS: As MSCT and CBCT apparatuses, Somatom Sensation 64 and 3D Accuitomo instruments, respectively, were used. As an objective evaluation of spatial resolution of these CT systems, modulation transfer function (MTF) analysis was performed employing an over-sampling method. The results of MTF analysis were confirmed with a line-pair test using CATPHAN. As a subjective evaluation, a microstructure visualization ability study was performed using a Jcl:SD rat and a head CT phantom.
RESULTS: MTF analysis showed that for the in-plane direction, the z-axis ultrahigh resolution mode (zUHR) of the Sensation 64 and 3D Accuitomo instruments had higher spatial resolutions than the conventional mode (64×) of the Sensation 64, but for the longitudinal direction, the 3D Accuitomo had clearly higher spatial resolution than either mode of the Sensation 64. A line-pair test study and microstructure visualization ability studies confirmed the results for MTF analysis. However, images of the rat and the CT phantom revealed that the 3D Accuitomo demonstrated the failure to visualize the soft tissues along with aliasing and beam-hardening artifacts, which were not observed in the Sensation 64.
CONCLUSIONS: This study successfully applied spatial resolution analysis using MSCT and CBCT systems in a comparative manner. These findings could help in deciding which CT modality should be selected for various clinical cases. Crown
Copyright © 2009. Published by Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19819091     DOI: 10.1016/j.ejrad.2009.09.023

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  34 in total

1.  Development of a low-dose protocol for cone beam CT examinations of the anterior maxilla in children.

Authors:  Jose A Hidalgo Rivas; Keith Horner; Badri Thiruvenkatachari; Jonathan Davies; Chrysoula Theodorakou
Journal:  Br J Radiol       Date:  2015-08-17       Impact factor: 3.039

2.  Anatomic variations and lesions of the mandibular canal detected by cone beam computed tomography.

Authors:  Guilherme Mariano Fiuza Leite; Juliana Pelinsari Lana; Vinícius de Carvalho Machado; Flávio Ricardo Manzi; Paulo Eduardo Alencar Souza; Martinho Campolina Rebello Horta
Journal:  Surg Radiol Anat       Date:  2013-12-15       Impact factor: 1.246

3.  A comparative study for image quality and radiation dose of a cone beam computed tomography scanner and a multislice computed tomography scanner for paranasal sinus imaging.

Authors:  Jens De Cock; Federica Zanca; John Canning; Ruben Pauwels; Robert Hermans
Journal:  Eur Radiol       Date:  2015-03-15       Impact factor: 5.315

4.  The dimensions of the facial alveolar bone at tooth sites with local pathologies: a retrospective cone-beam CT analysis.

Authors:  Ausra Ramanauskaite; K Becker; H C Kassira; J Becker; R Sader; F Schwarz
Journal:  Clin Oral Investig       Date:  2019-08-15       Impact factor: 3.573

5.  The role of cone beam CT in the study of symptomatic total knee arthroplasty (TKA): a 20 cases report.

Authors:  Cosimo Nardi; Roberto Buzzi; Roberto Molteni; Carlo Cossi; Chiara Lorini; Linda Calistri; Stefano Colagrande
Journal:  Br J Radiol       Date:  2017-05-25       Impact factor: 3.039

Review 6.  Quality assurance phantoms for cone beam computed tomography: a systematic literature review.

Authors:  Marcus V L de Oliveira; Ann Wenzel; Paulo S F Campos; Rubens Spin-Neto
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

Review 7.  Radiation dose in non-dental cone beam CT applications: a systematic review.

Authors:  Cosimo Nardi; Sergio Salerno; Roberto Molteni; Mariaelena Occhipinti; Giulia Grazzini; Niccolò Norberti; Cesare Cordopatri; Stefano Colagrande
Journal:  Radiol Med       Date:  2018-06-05       Impact factor: 3.469

8.  Electronic processing of digital panoramic radiography for the detection of apical periodontitis.

Authors:  Cosimo Nardi; Linda Calistri; Michele Pietragalla; Chiara Vignoli; Chiara Lorini; Valentina Berti; Francesco Mungai; Stefano Colagrande
Journal:  Radiol Med       Date:  2019-11-07       Impact factor: 3.469

9.  Metal and motion artifacts by cone beam computed tomography (CBCT) in dental and maxillofacial study.

Authors:  Cosimo Nardi; Claudia Borri; Francesco Regini; Linda Calistri; Alessandro Castellani; Chiara Lorini; Stefano Colagrande
Journal:  Radiol Med       Date:  2015-01-30       Impact factor: 3.469

10.  Assessment of phantom dosimetry and image quality of i-CAT FLX cone-beam computed tomography.

Authors:  John B Ludlow; Cameron Walker
Journal:  Am J Orthod Dentofacial Orthop       Date:  2013-12       Impact factor: 2.650

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.