Literature DB >> 15779030

High-resolution diffusion-weighted imaging with interleaved variable-density spiral acquisitions.

Tie-Qiang Li1, Dong-Hyun Kim, Michael E Moseley.   

Abstract

PURPOSE: To develop a multishot magnetic resonance imaging (MRI) pulse sequence and reconstruction algorithm for diffusion-weighted imaging (DWI) in the brain with submillimeter in-plane resolution.
MATERIALS AND METHODS: A self-navigated multishot acquisition technique based on variable-density spiral k-space trajectory design was implemented on clinical MRI scanners. The image reconstruction algorithm takes advantage of the oversampling of the center k-space and uses the densely sampled central portion of the k-space data for both imaging reconstruction and motion correction. The developed DWI technique was tested in an agar gel phantom and three healthy volunteers.
RESULTS: Motions result in phase and k-space shifts in the DWI data acquired using multishot spiral acquisitions. With the two-dimensional self-navigator correction, diffusion-weighted images with a resolution of 0.9 x 0.9 x 3 mm3 were successfully obtained using different interleaves ranging from 8-32. The measured apparent diffusion coefficient (ADC) in the homogenous gel phantom was (1.66 +/- 0.09) x 10(-3) mm2/second, which was the same as measured with single-shot methods. The intersubject average ADC from the brain parenchyma of normal adults was (0.91 +/- 0.01) x 10(-3) mm2/second, which was in a good agreement with the reported literature values.
CONCLUSION: The self-navigated multishot variable-density spiral acquisition provides a time-efficient approach to acquire high-resolution diffusion-weighted images on a clinical scanner. The reconstruction algorithm based on motion correction in the k-space data is robust, and measured ADC values are accurate and reproducible.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15779030     DOI: 10.1002/jmri.20287

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  11 in total

1.  High-resolution reduced field of view diffusion tensor imaging using spatially selective RF pulses.

Authors:  Wolfgang Gaggl; Andrzej Jesmanowicz; Robert W Prost
Journal:  Magn Reson Med       Date:  2014-01-07       Impact factor: 4.668

2.  Human brain diffusion tensor imaging at submillimeter isotropic resolution on a 3Tesla clinical MRI scanner.

Authors:  Hing-Chiu Chang; Mark Sundman; Laurent Petit; Shayan Guhaniyogi; Mei-Lan Chu; Christopher Petty; Allen W Song; Nan-kuei Chen
Journal:  Neuroimage       Date:  2015-06-11       Impact factor: 6.556

3.  Inherent correction of motion-induced phase errors in multishot spiral diffusion-weighted imaging.

Authors:  Trong-Kha Truong; Nan-kuei Chen; Allen W Song
Journal:  Magn Reson Med       Date:  2011-12-28       Impact factor: 4.668

4.  Diffusion MRI using two-dimensional single-shot radial imaging (2D ss-rDWI) with variable flip angle and random view ordering.

Authors:  Kyle E Jeong; Edward W Hsu; Eun-Kee Jeong
Journal:  Magn Reson Imaging       Date:  2019-04-19       Impact factor: 2.546

5.  Motion immune diffusion imaging using augmented MUSE for high-resolution multi-shot EPI.

Authors:  Shayan Guhaniyogi; Mei-Lan Chu; Hing-Chiu Chang; Allen W Song; Nan-Kuei Chen
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

6.  White matter pathology isolates the hippocampal formation in Alzheimer's disease.

Authors:  D H Salat; D S Tuch; A J W van der Kouwe; D N Greve; V Pappu; S Y Lee; N D Hevelone; A K Zaleta; J H Growdon; S Corkin; B Fischl; H D Rosas
Journal:  Neurobiol Aging       Date:  2010-02       Impact factor: 4.673

7.  High efficiency, low distortion 3D diffusion tensor imaging with variable density spiral fast spin echoes (3D DW VDS RARE).

Authors:  Lawrence R Frank; Youngkyoo Jung; Souheil Inati; J Michael Tyszka; Eric C Wong
Journal:  Neuroimage       Date:  2009-09-22       Impact factor: 6.556

8.  High-resolution multishot spiral diffusion tensor imaging with inherent correction of motion-induced phase errors.

Authors:  Trong-Kha Truong; Arnaud Guidon
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

9.  Magnetic resonance elastography of the brain using multishot spiral readouts with self-navigated motion correction.

Authors:  Curtis L Johnson; Matthew D J McGarry; Elijah E W Van Houten; John B Weaver; Keith D Paulsen; Bradley P Sutton; John G Georgiadis
Journal:  Magn Reson Med       Date:  2012-09-21       Impact factor: 4.668

10.  Robust diffusion tensor imaging by spatiotemporal encoding: Principles and in vivo demonstrations.

Authors:  Eddy Solomon; Gilad Liberman; Noam Nissan; Lucio Frydman
Journal:  Magn Reson Med       Date:  2016-03-10       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.