Literature DB >> 10893527

Sampling and reconstruction effects due to motion in diffusion-weighted interleaved echo planar imaging.

D Atkinson1, D A Porter, D L Hill, F Calamante, A Connelly.   

Abstract

Subject motion during diffusion-weighted interleaved echo-planar imaging causes k-space offsets which lead to irregular sampling in the phase-encode direction. For each image, the k-space shifts are monitored using 2D navigator echoes, and are shown to lead to a frequent violation of the Nyquist condition when an ungated sequence is used on seven subjects. Combining data from four repeat acquisitions allows the Nyquist condition to be satisfied in all but 1% of images. Reconstruction of the irregularly-sampled data can be performed using a matrix inversion technique. The repeated acquisitions make the inversion more stable and additionally improve the signal-to-noise ratio. The resultant isotropic diffusion-weighted images and average apparent diffusion coefficient (ADC) maps show high resolution and enable clear localization of a stroke lesion. Residual ADC artifacts with a slow spatial variation are observed and assumed to originate from non-rigid pulsatile brain motion. Magn Reson Med 44:101-109, 2000. Copyright 2000 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2000        PMID: 10893527     DOI: 10.1002/1522-2594(200007)44:1<101::aid-mrm15>3.0.co;2-s

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  32 in total

1.  Isotropic resolution diffusion tensor imaging with whole brain acquisition in a clinically acceptable time.

Authors:  Derek Kenton Jones; Steve Charles Rees Williams; David Gasston; Mark Andrew Horsfield; Andrew Simmons; Robert Howard
Journal:  Hum Brain Mapp       Date:  2002-04       Impact factor: 5.038

2.  POCS-based reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE): A general algorithm for reducing motion-related artifacts.

Authors:  Mei-Lan Chu; Hing-Chiu Chang; Hsiao-Wen Chung; Trong-Kha Truong; Mustafa R Bashir; Nan-kuei Chen
Journal:  Magn Reson Med       Date:  2014-11-13       Impact factor: 4.668

3.  High-resolution human diffusion tensor imaging using 2-D navigated multishot SENSE EPI at 7 T.

Authors:  Ha-Kyu Jeong; John C Gore; Adam W Anderson
Journal:  Magn Reson Med       Date:  2012-05-16       Impact factor: 4.668

4.  3D diffusion tensor imaging with 2D navigated turbo spin echo.

Authors:  M von Mengershausen; D G Norris; W Driesel
Journal:  MAGMA       Date:  2005-09-09       Impact factor: 2.310

Review 5.  Foundations of advanced magnetic resonance imaging.

Authors:  Roland Bammer; Stefan Skare; Rexford Newbould; Chunlei Liu; Vincent Thijs; Stefan Ropele; David B Clayton; Gunnar Krueger; Michael E Moseley; Gary H Glover
Journal:  NeuroRx       Date:  2005-04

6.  A preliminary study of the effects of trigger timing on diffusion tensor imaging of the human spinal cord.

Authors:  P Summers; P Staempfli; T Jaermann; S Kwiecinski; S Kollias
Journal:  AJNR Am J Neuroradiol       Date:  2006-10       Impact factor: 3.825

7.  Readout-segmented EPI for rapid high resolution diffusion imaging at 3 T.

Authors:  Samantha J Holdsworth; Stefan Skare; Rexford D Newbould; Raphael Guzmann; Nikolas H Blevins; Roland Bammer
Journal:  Eur J Radiol       Date:  2007-11-05       Impact factor: 3.528

8.  Fast susceptibility-weighted imaging with three-dimensional short-axis propeller (SAP)-echo-planar imaging.

Authors:  Samantha J Holdsworth; Kristen W Yeom; Michael E Moseley; S Skare
Journal:  J Magn Reson Imaging       Date:  2014-06-23       Impact factor: 4.813

9.  Motion immune diffusion imaging using augmented MUSE for high-resolution multi-shot EPI.

Authors:  Shayan Guhaniyogi; Mei-Lan Chu; Hing-Chiu Chang; Allen W Song; Nan-Kuei Chen
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

10.  Motion artifact reduction in pediatric diffusion tensor imaging using fast prospective correction.

Authors:  A Alhamud; Paul A Taylor; Barbara Laughton; André J W van der Kouwe; Ernesta M Meintjes
Journal:  J Magn Reson Imaging       Date:  2014-06-17       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.