Literature DB >> 25753142

Accuracy of continuous noninvasive hemoglobin monitoring for the prediction of blood transfusions in trauma patients.

Samuel M Galvagno1,2, Peter Hu3,4, Shiming Yang5, Cheng Gao4, David Hanna6, Stacy Shackelford7,8, Colin Mackenzie3,4.   

Abstract

Early detection of hemorrhagic shock is required to facilitate prompt coordination of blood component therapy delivery to the bedside and to expedite performance of lifesaving interventions. Standard physical findings and vital signs are difficult to measure during the acute resuscitation stage, and these measures are often inaccurate until patients deteriorate to a state of decompensated shock. The aim of this study is to examine a severely injured trauma patient population to determine whether a noninvasive SpHb monitor can predict the need for urgent blood transfusion (universal donor or additional urgent blood transfusion) during the first 12 h of trauma patient resuscitation. We hypothesize that trends in continuous SpHb, combined with easily derived patient-specific factors, can identify the immediate need for transfusion in trauma patients. Subjects were enrolled if directly admitted to the trauma center, >17 years of age, and with a shock index (heart rate/systolic blood pressure) >0.62. Upon admission, a Masimo Radical-7 co-oximeter sensor (Masimo Corporation, Irvine, CA) was applied, providing measurement of continuous non-invasive hemoglobin (SpHb) levels. Blood was drawn and hemoglobin concentration analyzed and conventional pulse oximetry photopletysmograph signals were continuously recorded. Demographic information and both prehospital and admission vital signs were collected. The primary outcome was transfusion of at least one unit of packed red blood cells within 24 h of admission. Eight regression models (C1-C8) were evaluated for the prediction of blood use by comparing area under receiver operating curve (AUROC) at different time intervals after admission. 711 subjects had continuous vital signs waveforms available, to include heart rate (HR), SpHb and SpO2 trends. When SpHb was monitored for 15 min, SpHb did not increase AUROC for prediction of transfusion. The highest ROC was recorded for model C8 (age, sex, prehospital shock index, admission HR, SpHb and SpO2) for the prediction of blood products within the first 3 h of admission. When data from 15 min of continuous monitoring were analyzed, significant improvement in AUROC occurred as more variables were added to the model; however, the addition of SpHb to any of the models did not improve AUROC significantly for prediction of blood use within the first 3 h of admission in comparison to analysis of conventional oximetry features. The results demonstrate that SpHb monitoring, accompanied by continuous vital signs data and adjusted for age and sex, has good accuracy for the prediction of need for transfusion; however, as an independent variable, SpHb did not enhance predictive models in comparison to use of features extracted from conventional pulse oximetry. Nor was shock index better than conventional oximetry at discriminating hemorrhaging and prediction of casualties receiving blood. In this population of trauma patients, noninvasive SpHb monitoring, including both trends and absolute values, did not enhance the ability to predict the need for blood transfusion.

Entities:  

Keywords:  Blood transfusion; Continuous hemoglobin; Detection of hemorrhage; Hemorrhagic shock; Noninvasive monitoring; Transfusion prediction

Mesh:

Substances:

Year:  2015        PMID: 25753142     DOI: 10.1007/s10877-015-9671-1

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  16 in total

Review 1.  Photoplethysmography and its application in clinical physiological measurement.

Authors:  John Allen
Journal:  Physiol Meas       Date:  2007-02-20       Impact factor: 2.833

Review 2.  Accuracy of continuous noninvasive hemoglobin monitoring: a systematic review and meta-analysis.

Authors:  Sang-Hyun Kim; Marc Lilot; Linda Suk-Ling Murphy; Kulraj S Sidhu; Zhaoxia Yu; Joseph Rinehart; Maxime Cannesson
Journal:  Anesth Analg       Date:  2014-08       Impact factor: 5.108

3.  Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach.

Authors:  E R DeLong; D M DeLong; D L Clarke-Pearson
Journal:  Biometrics       Date:  1988-09       Impact factor: 2.571

Review 4.  Optimal use of blood products in severely injured trauma patients.

Authors:  John B Holcomb
Journal:  Hematology Am Soc Hematol Educ Program       Date:  2010

5.  Blood product use in trauma resuscitation: plasma deficit versus plasma ratio as predictors of mortality in trauma (CME).

Authors:  Andreas R de Biasi; Lynn G Stansbury; Richard P Dutton; Deborah M Stein; Thomas M Scalea; John R Hess
Journal:  Transfusion       Date:  2011-02-18       Impact factor: 3.157

6.  Prehospital dynamic tissue oxygen saturation response predicts in-hospital lifesaving interventions in trauma patients.

Authors:  Francis X Guyette; Hernando Gomez; Brian Suffoletto; Jorge Quintero; Jaume Mesquida; Hyung Kook Kim; David Hostler; Juan-Carlos Puyana; Michael R Pinsky
Journal:  J Trauma Acute Care Surg       Date:  2012-04       Impact factor: 3.313

7.  Trending and accuracy of noninvasive hemoglobin monitoring in pediatric perioperative patients.

Authors:  Mario Patino; Lindsay Schultz; Monir Hossain; Jennifer Moeller; Mohamed Mahmoud; Joel Gunter; C Dean Kurth
Journal:  Anesth Analg       Date:  2014-10       Impact factor: 5.108

8.  Predicting the need for massive transfusion in trauma patients: the Traumatic Bleeding Severity Score.

Authors:  Takayuki Ogura; Yoshihiko Nakamura; Minoru Nakano; Yoshimitsu Izawa; Mitsunobu Nakamura; Kenji Fujizuka; Masayuki Suzukawa; Alan T Lefor
Journal:  J Trauma Acute Care Surg       Date:  2014-05       Impact factor: 3.313

9.  Blood transfusion rates in the care of acute trauma.

Authors:  John J Como; Richard P Dutton; Thomas M Scalea; Bennett B Edelman; John R Hess
Journal:  Transfusion       Date:  2004-06       Impact factor: 3.157

10.  Accuracy of point-of-care-testing (POCT) for determining hemoglobin concentrations.

Authors:  H Gehring; C Hornberger; L Dibbelt; A Rothsigkeit; K Gerlach; J Schumacher; P Schmucker
Journal:  Acta Anaesthesiol Scand       Date:  2002-09       Impact factor: 2.105

View more
  9 in total

Review 1.  Journal of Clinical Monitoring and Computing 2015 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Karim Bendjelid; Steffen Rex; Thomas Scheeren; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

2.  Noninvasively Measured Hemoglobin Concentration Reflects Arterial Hemoglobin Concentration Before but Not After Cardiopulmonary Bypass in Patients Undergoing Coronary Artery or Valve Surgery.

Authors:  Matthias L Riess; Paul S Pagel
Journal:  J Cardiothorac Vasc Anesth       Date:  2016-03-24       Impact factor: 2.628

3.  Accuracy of non-invasive continuous total hemoglobin measurement by Pulse CO-Oximetry in severe traumatized and surgical bleeding patients.

Authors:  Werner Baulig; Burkhardt Seifert; Donat R Spahn; Oliver M Theusinger
Journal:  J Clin Monit Comput       Date:  2015-12-19       Impact factor: 2.502

4.  Accuracy and trending of non-invasive hemoglobin measurement during different volume and perfusion statuses.

Authors:  Abdelmoneim Adel; Wael Awada; Bassant Abdelhamid; Heba Omar; Omnia Abd El Dayem; Ahmed Hasanin; Ashraf Rady
Journal:  J Clin Monit Comput       Date:  2018-01-15       Impact factor: 2.502

5.  Continuous Vital Sign Analysis to Predict Secondary Neurological Decline After Traumatic Brain Injury.

Authors:  Christopher Melinosky; Shiming Yang; Peter Hu; HsiaoChi Li; Catriona H T Miller; Imad Khan; Colin Mackenzie; Wan-Tsu Chang; Gunjan Parikh; Deborah Stein; Neeraj Badjatia
Journal:  Front Neurol       Date:  2018-09-25       Impact factor: 4.003

6.  Intraoperative continuous noninvasive hemoglobin monitoring in patients with placenta previa undergoing cesarean section: a prospective observational study.

Authors:  Hyunsung Kim; Sang-Hwan Do; Jung-Won Hwang; Hyo-Seok Na
Journal:  Anesth Pain Med (Seoul)       Date:  2019-10-31

7.  Intelligent prediction of RBC demand in trauma patients using decision tree methods.

Authors:  Yan-Nan Feng; Zhen-Hua Xu; Jun-Ting Liu; Xiao-Lin Sun; De-Qing Wang; Yang Yu
Journal:  Mil Med Res       Date:  2021-05-24

8.  Fatal and nonfatal firearm injuries in the eastern Democratic Republic of Congo: a hospital-based retrospective descriptive cohort study assessing correlates of adult mortality.

Authors:  Paul Munguakonkwa Budema; Roméo Bujiriri Murhega; Tshibambe Nathanael Tshimbombu; Georges Kuyigwa Toha; Fabrice Gulimwentuga Cikomola; Paterne Safari Mudekereza; Léon-Emmanuel Mubenga; Ghislain Maheshe-Balemba; Darck Cubaka Badesire; Ulrick Sidney Kanmounye
Journal:  BMC Emerg Med       Date:  2021-10-12

9.  Postoperative Noninvasive Hemoglobin Monitoring Is Useful to Prevent Unnoticed Postoperative Anemia and Inappropriate Blood Transfusion in Patients Undergoing Total Hip or Knee Arthroplasty: A Randomized Controlled Trial.

Authors:  Erisa Nakamori; Kenji Shigematsu; Midoriko Higashi; Ken Yamaura
Journal:  Geriatr Orthop Surg Rehabil       Date:  2021-11-19
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.