Literature DB >> 24914627

Accuracy of continuous noninvasive hemoglobin monitoring: a systematic review and meta-analysis.

Sang-Hyun Kim1, Marc Lilot, Linda Suk-Ling Murphy, Kulraj S Sidhu, Zhaoxia Yu, Joseph Rinehart, Maxime Cannesson.   

Abstract

BACKGROUND: Noninvasive hemoglobin (Hb) monitoring devices are available in the clinical setting, but their accuracy and precision against central laboratory Hb measurements have not been evaluated in a systematic review and meta-analysis.
METHODS: We conducted a comprehensive search of the literature (2005 to August 2013) with PubMed, Web of Science and the Cochrane Library, reviewed references of retrieved articles, and contacted manufactures to identify studies assessing the accuracy of noninvasive Hb monitoring against central laboratory Hb measurements. Two independent reviewers assessed the quality of studies using recommendations for reporting guidelines and quality criteria for method comparison studies. Pooled mean difference and standard deviation (SD) (95% limits of agreement) across studies were calculated using the random-effects model. Heterogeneity was assessed using the I statistic.
RESULTS: A total of 32 studies (4425 subjects, median sample size of 44, ranged from 10 to 569 patients per study) were included in this meta-analysis. The overall pooled random-effects mean difference (noninvasive-central laboratory) and SD were 0.10 ± 1.37 g/dL (-2.59 to 2.80 g/dL, I = 95.9% for mean difference and 95.0% for SD). In subgroup analysis, pooled mean difference and SD were 0.39 ± 1.32 g/dL (-2.21 to 2.98 g/dL, I = 93.0%, 71.4%) in 13 studies conducted in the perioperative setting and were -0.51 ± 1.59 g/dL (-3.63 to 2.62 g/dL, I = 83.7%, 96.4%) in 5 studies performed in the intensive care unit setting.
CONCLUSIONS: Although the mean difference between noninvasive Hb and central laboratory measurements was small, the wide limits of agreement mean clinicians should be cautious when making clinical decisions based on these devices.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24914627     DOI: 10.1213/ANE.0000000000000272

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  19 in total

Review 1.  Journal of Clinical Monitoring and Computing 2015 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Karim Bendjelid; Steffen Rex; Thomas Scheeren; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

2.  mHealth spectroscopy of blood hemoglobin with spectral super-resolution.

Authors:  Sang Mok Park; Michelle A Visbal-Onufrak; Md Munirul Haque; Martin C Were; Violet Naanyu; Md Kamrul Hasan; Young L Kim
Journal:  Optica       Date:  2020-06-20       Impact factor: 11.104

Review 3.  Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis.

Authors:  Koichi Suehiro; Alexandre Joosten; Linda Suk-Ling Murphy; Olivier Desebbe; Brenton Alexander; Sang-Hyun Kim; Maxime Cannesson
Journal:  J Clin Monit Comput       Date:  2015-08-29       Impact factor: 2.502

4.  Detection of anaemia from retinal fundus images via deep learning.

Authors:  Yun Liu; Avinash V Varadarajan; Akinori Mitani; Abigail Huang; Subhashini Venugopalan; Greg S Corrado; Lily Peng; Dale R Webster; Naama Hammel
Journal:  Nat Biomed Eng       Date:  2019-12-23       Impact factor: 25.671

5.  Comparison of invasive and noninvasive blood hemoglobin measurement in the operating room: a systematic review and meta-analysis.

Authors:  Hosein Shabaninejad; Nashmil Ghadimi; Kourosh Sayehmiri; Hossein Hosseinifard; Rasoul Azarfarin; Hasan Abolghasem Gorji
Journal:  J Anesth       Date:  2019-03-20       Impact factor: 2.078

6.  Accuracy of continuous noninvasive hemoglobin monitoring for the prediction of blood transfusions in trauma patients.

Authors:  Samuel M Galvagno; Peter Hu; Shiming Yang; Cheng Gao; David Hanna; Stacy Shackelford; Colin Mackenzie
Journal:  J Clin Monit Comput       Date:  2015-03-10       Impact factor: 2.502

7.  Accuracy and trending of non-invasive hemoglobin measurement during different volume and perfusion statuses.

Authors:  Abdelmoneim Adel; Wael Awada; Bassant Abdelhamid; Heba Omar; Omnia Abd El Dayem; Ahmed Hasanin; Ashraf Rady
Journal:  J Clin Monit Comput       Date:  2018-01-15       Impact factor: 2.502

8.  Evaluation of a Noninvasive Hemoglobin Measurement Device to Screen for Anemia in Infancy.

Authors:  Daniel P Hsu; Alicia J French; Samuel L Madson; John M Palmer; Vinod Gidvani-Diaz
Journal:  Matern Child Health J       Date:  2016-04

Review 9.  Point-of-care diagnostics for niche applications.

Authors:  Brian M Cummins; Frances S Ligler; Glenn M Walker
Journal:  Biotechnol Adv       Date:  2016-02-01       Impact factor: 14.227

10.  The Prevalence and Clinical Significance of Preoperative Thrombocytopenia in Adults Undergoing Elective Surgery: An Observational Cohort Study.

Authors:  Luke J Matzek; Andrew C Hanson; Phillip J Schulte; Kimberly D Evans; Daryl J Kor; Matthew A Warner
Journal:  Anesth Analg       Date:  2021-03-01       Impact factor: 6.627

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.