Literature DB >> 25710022

Athletic differences in the characteristics of the photoplethysmographic pulse shape: effect of maximal oxygen uptake and maximal muscular voluntary contraction.

Anran Wang1, Lin Yang1, Chengyu Liu2, Jingxuan Cui1, Yao Li1, Xingxing Yang1, Song Zhang1, Dingchang Zheng3.   

Abstract

This study aimed to investigate the athletic differences in the characteristics of the photoplethysmographic (PPG) pulse shape. 304 athletes were enrolled and divided into three subgroups according to a typical sport classification in terms of the maximal oxygen uptake (MaxO2_low, MaxO2_middle and MaxO2_high groups) or the maximal muscular voluntary contraction (MMVC_low, MMVC_middle, and MMVC_high groups). Finger PPG pulses were digitally recorded and then normalized to derive the pulse area, pulse peak time T p , dicrotic notch time T n , and pulse reflection index (RI). The four parameters were finally compared between the three subgroups categorized by MaxO2 or by MMVC. In conclusion, it has been demonstrated by quantifying the characteristics of the PPG pulses in different athletes that MaxO2, but not MMVC, had significant effect on the arterial properties.

Entities:  

Mesh:

Year:  2015        PMID: 25710022      PMCID: PMC4332975          DOI: 10.1155/2015/752570

Source DB:  PubMed          Journal:  Biomed Res Int            Impact factor:   3.411


1. Introduction

The measurement of arterial properties is a common screening tool for the assessment of human health [1, 2]. It has been widely accepted that physical exercise could effectively improve the cardiovascular function and peripheral circulation [3, 4]. It is useful to monitor the physiological state of the arteries in athletes. However, current research on the assessment of arterial properties in athletes is very limited, and the published studies mainly focused on single sport type, such as marathon, triathlon, or swimming athletes [5, 6]. Therefore, it would be scientifically useful to have a comprehensive and systematic research study to assess arterial properties from a wide range of athletes. Many noninvasive methods have been used to assess or quantify the arterial properties. The arterial pulse propagation time or the pulse wave velocity (PWV) [7, 8] is one of the commonly used methods. The stiffer the artery is, the shorter the pulse propagation time is. A cohort of 492 Japanese-Americans study demonstrated that pulse propagation time can predict cardiovascular disease mortality [9]. The importance of measuring pulse propagation time has already been shown under different clinical conditions [10, 11]. However, in practice, pulse propagation time is calculated from the arrival time of the pulse at the periphery from a reference time, and this is often the R peak of the QRS complex of the electrocardiogram (ECG). Unfortunately, this measurement of pulse propagation time includes the left ventricular electrical depolarization and mechanical preejection times. It cannot precisely represent the properties of the peripheral arteries [12]. Analysis of the characteristics of the arterial pulse shape has also been commonly used. This method only requires the measurement of arterial pulses, and it has been reported that the arterial pulse waveforms are affected by aging [13], heart failure [14], and other physiological or pathological conditions [15-17]. However, there is no existing study to compare the waveform difference of the arterial pulses recorded from different types of athletes. This study aimed to investigate the athletic differences in the characteristics of the arterial pulse shape. The noninvasive photoplethysmographic (PPG) pulses were used in this study due to its simplicity [18, 19].

2. Materials and Methods

2.1. Subjects

304 professional athletes were enrolled from Beijing Muxiyuan Sports Technical School. They have been actively trained for at least 3 years, and a wide range of different sports was covered in this study, as shown in Figure 1. This study was fully approved by the local Ethics Committee, College of Life Science and Bioengineering, Beijing University of Technology. Information consent was obtained from each subject prior to the measurement.
Figure 1

Classification of sports according to dynamic and static exercise components [21]. A total of 304 athletes were studied, and the numbers of athletes in each category are shown.

A typical sport classification scheme considered that each sport has dynamic and static exercise components [20, 21]. The dynamic exercise component is defined in terms of the percent of maximal oxygen uptake (MaxO2) achieved (three levels): MaxO2_low group: MaxO2 < 40%; MaxO2_middle group: 40% ≤ MaxO2 ≤ 70%; MaxO2_high group: MaxO2 > 70%. The static exercise component is related to the percent of maximal muscular voluntary contraction (MMVC) reached (three levels): MMVC_low group: MMVC < 20%; MMVC_middle group: 20% ≤  MMVC ≤50%; MMVC_high group: MMVC > 50%. According to the sports classification scheme, all 304 athletes in this study were categorized by the levels of MaxO2 (low, middle, and high) and MMVC (low, middle, and high). Figure 1 also shows the number of athletes in each category, and Table 1 gives the overall basic clinical information, including the age, height, and weight, for the three subgroups classified by MaxO2 or by MMVC.
Table 1

Clinical variables from the 304 athletes studied.

VariablesMaxO2 subgroupsMMVC subgroups
LowMiddleHigh P valueLowMiddleHigh P value
No.601101340.113084900.4
Gender (F/M)30/3055/5567/671.065/6542/4245/451.0
Age, year20 ± 218 ± 420 ± 2<0.0520 ± 420 ± 219 ± 3<0.05
Height, cm172 ± 10172 ± 10174 ± 70.3172 ± 8177 ± 9170 ± 9<0.05
Weight, kg71 ± 2163 ± 1263 ± 9<0.0562 ± 1265 ± 1267 ± 16<0.05
HR, beats/min66 ± 1166 ± 1060 ± 10<0.0572 ± 964 ± 1366 ± 100.1
SBP, mmHg116 ± 12118 ± 10116 ± 90.4116 ± 9119 ± 10117 ± 130.1
DBP, mmHg71 ± 967 ± 872 ± 8<0.0572 ± 771 ± 867 ± 10<0.05
PP, mmHg45 ± 1050 ± 1145 ± 8<0.0544 ± 748 ± 950 ± 13<0.05

Note: HR: heart rate, SBP: systolic blood pressure, DBP: diastolic blood pressure, and PP: pulse pressure; P value obtained from ANOVA analysis measures the differences between the three subgroups categorized by MaxO2 or MMVC.

2.2. PPG Pulse Collection

Each athlete was asked to sit quietly for 3 minutes before the pulse recording and keep relaxing during the whole measurement process. The optical PPG pulses were digitally recorded from the right middle finger using a PowerLab data collection system (ADInstruments Pty Ltd., PowerLab 8/35, Bella Vista, NSW, Australia) at a sampling rate of 1000 Hz. Since there is significant effect of the finger temperature on the PPG pulse shape [22], finger skin temperature was ensured to be around 25°C for each athlete. When the PPG pulse waveforms were satisfactory and stably shown on the monitoring screen, they were saved for 30 s to a computer for further off-line analysis.

2.3. Pulse Characteristics Determination

2.3.1. Pulse Waveform Normalization

For each athlete, the recorded finger PPG pulses were normalized beat-by-beat in both width (100 sampling points) and amplitude (0-1) from the foot of each pulse and then averaged to obtain a single reference pulse, as shown in Figure 2(a). This normalized pulse was used for subsequent determination of pulse characteristics.
Figure 2

Determination methods of the normalized PPG pulse waveform characteristic. Four parameters were defined, including the pulse area, pulse peak time T , dicrotic notch time T , and reflection index RI.

2.3.2. Pulse Area

The “pulse area” describes the global pulse wave characteristics [23], which was computed from the normalized pulse waveform as: Area = ∫0 100 Y(t)dt, as shown in Figure 2(a).

2.3.3. Pulse Peak Time

The pulse peak point T was determined from the first derivative PPG pulse, which was corresponding to the first zero-crossing point after the pulse peak, as shown in Figure 2(b).

2.3.4. Dicrotic Notch Time

The pulse dicrotic notch time T was determined from the second derivative PPG pulse, which was corresponding to the maximum point after the pulse peak point T , as shown in Figure 2(c).

2.3.5. Reflection Index (RI)

The PPG pulse has a diastolic peak after the systolic peak [24], and RI measures the vascular resistance of the peripheral arteries. As shown in Figure 2(a), RI was calculated from the height of the diastolic peak (P2) of the PPG waveform as a percentage of the systolic peak (P1), which is expressed as:  RI = P2/P1.

3. Results

3.1. Pulse Characteristics Difference between Three MaxO2 Subgroups

As shown in Figure 3 and Table 2, there were no significant differences in the pulse area, T , T , and RI between the MaxO2_low and MaxO2_middle groups, but they were all significantly lower in the MaxO2_high group than both the MaxO2_low and MaxO2_middle groups (all P < 0.05).
Figure 3

Differences of the PPG pulse characteristics (pulse Area, pulse peak time T , and dicrotic notch time T ) between the three MaxO2 subgroups.

Table 2

Differences of PPG pulse characteristics between the three subgroups catergoised by MaxO2 or MMVC.

ParametersMaxO2 subgroups MMVC subgroups
LowMiddleHigh P valueLowMiddleHigh P value
Area51 ± 7.151 ± 5.345 ± 6.1<0.0547 ± 6.848 ± 6.751 ± 6.2<0.05
T p 19 ± 5.520 ± 5.117 ± 4.2<0.0519 ± 5.319 ± 4.620 ± 5.20.3
T n 36 ± 5.238 ± 6.932 ± 6.1<0.0537 ± 6.738 ± 7.439 ± 5.80.9
RI0.73 ± 0.130.74 ± 0.110.69 ± 0.12<0.050.71 ± 0.110.71 ± 0.120.73 ± 0.130.5

3.2. Pulse Characteristics Difference between Three MMVC Subgroups

As shown in Figure 4 and Table 2, there were no significant differences in all pulse characteristics between the three subgroups (all P > 0.3), except for the pulse area between the MMVC_low and MMVC_high groups (P < 0.05).
Figure 4

Reflection index (RI) difference between the three MaxO2 subgroups.

4. Discussion

The measurement of arterial PPG pulse is an effective method to monitor and evaluate the peripheral artery properties. In this study, the finger PPG pulse shape and their characteristics in different athletes have been quantitatively compared. To the best of our knowledge, this is the first comprehensive study to investigate the athletic effect on arterial pulse shape. In the athletes requiring high MaxO2, the smaller pulse area has been observed in this study. Pulse area has been reported to be increased with the elevation of blood pressure and the increase of arteriosclerosis degree [25]; hence it decreased in subjects with better arterial compliance. The smaller pulse area observed in the MaxO2_high group indicated that more compliant arteries would be expected in these athletes. Our finding agrees well with some published studies [26-28], where the endurance exercise training (such as long- or middle-distance runners who require higher MaxO2) could induce an increased arterial distensibility, whereas the strength exercise training (such as discus, hammer, or javelin throwers) decreased the arterial distensibility. This study also showed that the pulse peak time, dicrotic notch time, and RI were significantly decreased in the MaxO2_high group. It has been accepted that, for the younger group with good vascular wall elasticity, the rising velocity of pulse ascending curve is faster or the pulse peak time is shorter when compared with the older group [24]. In addition, since the RI measures peripheral resistance, it has also been accepted that peripheral resistance in the younger group is lower, leading to lower RI, more obvious dicrotic notch point, and shorter time duration between the foot of the pulse and the notch point [24, 29]. With similar physiological mechanisms, because more compliant arteries are expected in the MaxO2_high group, shorter pulse peak and dicrotic notch times and lower RI would be observed. This has been confirmed in this study. Next, for the effect of MMVC on the arterial properties, it has been published that when compared with the healthy subjects the strength-trained athletes (corresponding to the MMVC_high group in this study) had decreased arterial compliance [28]. Similar result was observed in this study, where smaller pulse area has been quantified in the MMVC_high group in comparison with the MMVC_low group. However, there were no significant differences in the other three pulse characteristics (T , T , and RI) between the three MMVC subgroups (Figures 5 and 6), indicating that the effect of MMVC on the decrease of arterial compliance is not so obvious. Further investigations could therefore be followed to better understand the potential difference underlying physiological mechanisms for the different effects of MaxO2 and MMVC on arterial properties.
Figure 5

Differences of the PPG pulse characteristics (pulse area, pulse peak time T , and dicrotic notch time T ) between the three MMVC subgroups.

Figure 6

Reflection index (RI) difference between the three MMVC subgroups.

5. Conclusion

It has been demonstrated by quantifying the characteristics of the PPG pulses in different athletes that MaxO2, but not MMVC, had significant effect on the arterial properties.
  28 in total

1.  Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes.

Authors:  J Allen; A Murray
Journal:  J Hum Hypertens       Date:  2002-10       Impact factor: 3.012

2.  Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery.

Authors:  M O Fischer; R Avram; I Cârjaliu; M Massetti; J L Gérard; J L Hanouz; J L Fellahi
Journal:  Br J Anaesth       Date:  2012-07-01       Impact factor: 9.166

3.  Characteristic alteration in the second derivative of photoplethysmogram in children.

Authors:  Satoshi Hasegawa; Seiichi Sato; Fujito Numano; Jiksoo Park; Satoshi Hoshina; Hikosato Endoh; Hiroshi Suzuki; Makoto Uchiyama
Journal:  Pediatr Int       Date:  2011-04       Impact factor: 1.524

4.  Invasive validation of a new oscillometric device (Arteriograph) for measuring augmentation index, central blood pressure and aortic pulse wave velocity.

Authors:  Iván G Horváth; Adám Németh; Zsófia Lenkey; Nicola Alessandri; Fabrizio Tufano; Pál Kis; Balázs Gaszner; Attila Cziráki
Journal:  J Hypertens       Date:  2010-10       Impact factor: 4.844

5.  Arterial stiffness and wave reflections in marathon runners.

Authors:  Charalambos Vlachopoulos; Despina Kardara; Aris Anastasakis; Katerina Baou; Dimitrios Terentes-Printzios; Dimitris Tousoulis; Christodoulos Stefanadis
Journal:  Am J Hypertens       Date:  2010-05-20       Impact factor: 2.689

6.  Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease.

Authors:  L W J Bogert; K H Wesseling; O Schraa; E J Van Lieshout; B A J M de Mol; J van Goudoever; B E Westerhof; J J van Lieshout
Journal:  Anaesthesia       Date:  2010-09-21       Impact factor: 6.955

7.  Pulse wave velocity predicts cardiovascular mortality: findings from the Hawaii-Los Angeles-Hiroshima study.

Authors:  Tomoki Shokawa; Michinori Imazu; Hideya Yamamoto; Mamoru Toyofuku; Naohito Tasaki; Tomokazu Okimoto; Kiminori Yamane; Nobuoki Kohno
Journal:  Circ J       Date:  2005-03       Impact factor: 2.993

8.  Age-related abnormalities in arterial compliance identified by pressure pulse contour analysis: aging and arterial compliance.

Authors:  G E McVeigh; C W Bratteli; D J Morgan; C M Alinder; S P Glasser; S M Finkelstein; J N Cohn
Journal:  Hypertension       Date:  1999-06       Impact factor: 10.190

9.  Photoplethysmographic assessment of hemodynamic variations using pulsatile tissue blood volume.

Authors:  Jong Y A Foo; Chu S Lim; Stephen J Wilson
Journal:  Angiology       Date:  2008-04-02       Impact factor: 3.619

10.  Physical training improves endothelial function in patients with chronic heart failure.

Authors:  B Hornig; V Maier; H Drexler
Journal:  Circulation       Date:  1996-01-15       Impact factor: 29.690

View more
  7 in total

1.  Investigation of peripheral photoplethysmographic morphology changes induced during a hand-elevation study.

Authors:  Michelle Hickey; Justin P Phillips; Panayiotis A Kyriacou
Journal:  J Clin Monit Comput       Date:  2015-08-29       Impact factor: 2.502

2.  Optical coherence tomography angiography measures blood pulsatile waveforms at variable tissue depths.

Authors:  Zhiying Xie; Geng Wang; Yuxuan Cheng; Qinqin Zhang; Minh Nhan Le; Ruikang K Wang
Journal:  Quant Imaging Med Surg       Date:  2021-03

3.  Quantification of radial arterial pulse characteristics change during exercise and recovery.

Authors:  Anran Wang; Lin Yang; Weimin Wen; Song Zhang; Dongmei Hao; Syed G Khalid; Dingchang Zheng
Journal:  J Physiol Sci       Date:  2016-12-27       Impact factor: 2.781

4.  Postoperative Pain Assessment Indices Based on Photoplethysmography Waveform Analysis.

Authors:  Yoon La Yang; Hyeon Seok Seok; Gyu-Jeong Noh; Byung-Moon Choi; Hangsik Shin
Journal:  Front Physiol       Date:  2018-08-28       Impact factor: 4.566

5.  Recovery Responses of Central Hemodynamics in Basketball Athletes and Controls After the Bruce Test.

Authors:  Yahui Zhang; Lin Qi; Frans van de Vosse; Chenglin Du; Yudong Yao; Jianhang Du; Guifu Wu; Lisheng Xu
Journal:  Front Physiol       Date:  2020-11-12       Impact factor: 4.566

6.  Changes of Arterial Pulse Waveform Characteristics with Gestational Age during Normal Pregnancy.

Authors:  Kunyan Li; Song Zhang; Lin Yang; Hongqing Jiang; Zhenyu Chi; Anran Wang; Yimin Yang; Xuwen Li; Dongmei Hao; Lei Zhang; Dingchang Zheng
Journal:  Sci Rep       Date:  2018-10-22       Impact factor: 4.379

7.  Characterization of Rat Cardiovascular System by Anacrotic/Dicrotic Notches in the Condition of Increase/Decrease of NO Bioavailability.

Authors:  Lenka Tomasova; Anton Misak; Lucia Kurakova; Marian Grman; Karol Ondrias
Journal:  Int J Mol Sci       Date:  2020-09-12       Impact factor: 5.923

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.