Literature DB >> 26318315

Investigation of peripheral photoplethysmographic morphology changes induced during a hand-elevation study.

Michelle Hickey1, Justin P Phillips2, Panayiotis A Kyriacou2.   

Abstract

A hand-elevation study was carried out in the laboratory in order to alter peripheral blood flow with the aim of increasing understanding of factors affecting the morphology of peripheral photoplethysmographic signals. Photoplethysmographic (PPG) signals were recorded from twenty healthy volunteer subjects during a hand-elevation study in which the right hand was raised and lowered relative to heart level, while the left hand remained static. Red and infrared (IR) PPG signals were obtained from the right and left index fingers using a custom-made PPG processing system. PPG features were identified using a feature-detection algorithm based on the first derivative of the PPG signal. The systolic PPG amplitude, the reflection index, crest time, pulse width at half height, and delta T were calculated from 20 s IR PPG signals from three positions of the right hand with respect to heart level (-50, 0, +50 cm) in 19 volunteers. PPG features were found to change with hand elevation. On lowering the hand to 50 cm below heart level, ac systolic PPG amplitudes from the finger decreased by 68.32 %, while raising the arm increased the systolic amplitude by 69.99 %. These changes in amplitude were attributed to changes in hydrostatic pressure and the veno-arterial reflex. Other morphological variables, such as crest time, were found to be statistically significantly different across hand positions, indicating increased vascular resistance on arm elevation than on dependency. It was hypothesized that these morphological PPG changes were influenced by changes in downstream venous resistance, rather than arterial, or arteriolar, resistance. Changes in hand position relative to heart level can significantly affect the morphology of the peripheral ac PPG waveform. These alterations are due to a combination of physical effects and physiological responses to changes in hand position, which alter vascular resistance. Care should be taken when interpreting morphological data derived from PPG signals and methods should be standardized to take these effects into account.

Entities:  

Keywords:  Hand elevation; PPG morphology; Photoplethysmography; Reflection index; Vascular mechanics; Vasoconstriction; Vasodilation

Mesh:

Year:  2015        PMID: 26318315     DOI: 10.1007/s10877-015-9761-0

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  31 in total

1.  Spontaneous fluctuations in the peripheral photoplethysmographic waveform: roles of arterial pressure and muscle sympathetic nerve activity.

Authors:  Gregory S H Chan; Azharuddin Fazalbhoy; Ingvars Birznieks; Vaughan G Macefield; Paul M Middleton; Nigel H Lovell
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-11-23       Impact factor: 4.733

2.  Noninvasive continuous monitoring of digital pulse waves during hemodialysis.

Authors:  Antje Burkert; Alexandra Scholze; Martin Tepel
Journal:  ASAIO J       Date:  2006 Mar-Apr       Impact factor: 2.872

3.  Blood flow rate in arteriovenous anastomoses and capillaries in thumb, first toe, ear lobe, and nose.

Authors:  M Midttun; P Sejrsen
Journal:  Clin Physiol       Date:  1996-05

4.  Blood pressure variation in response to changing arm cuff height cannot be explained solely by the hydrostatic effect.

Authors:  Benjamin Gavish; Leah Gavish
Journal:  J Hypertens       Date:  2011-11       Impact factor: 4.844

5.  Evaluating optimal superficial limb perfusion at different angles using non-invasive micro-lightguide spectrophotometry.

Authors:  Geraldine Darmanin; Matthew Jaggard; Shehan Hettiaratchy; Jagdeep Nanchahal; Abhilash Jain
Journal:  J Plast Reconstr Aesthet Surg       Date:  2013-03-15       Impact factor: 2.740

6.  Photoplethysmographic assessment of pulse wave reflection: blunted response to endothelium-dependent beta2-adrenergic vasodilation in type II diabetes mellitus.

Authors:  P J Chowienczyk; R P Kelly; H MacCallum; S C Millasseau; T L Andersson; R G Gosling; J M Ritter; E E Anggård
Journal:  J Am Coll Cardiol       Date:  1999-12       Impact factor: 24.094

7.  The effect of vascular changes on the photoplethysmographic signal at different hand elevations.

Authors:  M Hickey; J P Phillips; P A Kyriacou
Journal:  Physiol Meas       Date:  2015-02-05       Impact factor: 2.833

8.  The relationship between the photoplethysmographic waveform and systemic vascular resistance.

Authors:  Aymen A Awad; Ala S Haddadin; Hossam Tantawy; Tarek M Badr; Robert G Stout; David G Silverman; Kirk H Shelley
Journal:  J Clin Monit Comput       Date:  2007-10-17       Impact factor: 2.502

9.  Estimation of arterial stiffness, compliance, and distensibility from M-mode ultrasound measurements of the common carotid artery.

Authors:  G Gamble; J Zorn; G Sanders; S MacMahon; N Sharpe
Journal:  Stroke       Date:  1994-01       Impact factor: 7.914

10.  Noninvasive measurement of the human peripheral circulation: relationship between laser Doppler flowmeter and photoplethysmograph signals from the finger.

Authors:  N E Almond; D P Jones; E D Cooke
Journal:  Angiology       Date:  1988-09       Impact factor: 3.619

View more
  10 in total

Review 1.  Journal of Clinical Monitoring and Computing 2016 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Bernd Saugel; Karim Bendjelid; Lester A Critchley; Steffen Rex; Thomas W L Scheeren
Journal:  J Clin Monit Comput       Date:  2017-01-07       Impact factor: 2.502

2.  Wearable Photoplethysmography for Cardiovascular Monitoring.

Authors:  Peter H Charlton; Panicos A Kyriaco; Jonathan Mant; Vaidotas Marozas; Phil Chowienczyk; Jordi Alastruey
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2022-03-11       Impact factor: 10.961

3.  Optical coherence tomography angiography measures blood pulsatile waveforms at variable tissue depths.

Authors:  Zhiying Xie; Geng Wang; Yuxuan Cheng; Qinqin Zhang; Minh Nhan Le; Ruikang K Wang
Journal:  Quant Imaging Med Surg       Date:  2021-03

4.  Photoplethysmography for blood volumes and oxygenation changes during intermittent vascular occlusions.

Authors:  T Y Abay; P A Kyriacou
Journal:  J Clin Monit Comput       Date:  2017-05-25       Impact factor: 2.502

5.  Postoperative Pain Assessment Indices Based on Photoplethysmography Waveform Analysis.

Authors:  Yoon La Yang; Hyeon Seok Seok; Gyu-Jeong Noh; Byung-Moon Choi; Hangsik Shin
Journal:  Front Physiol       Date:  2018-08-28       Impact factor: 4.566

6.  Relationship Between Inflow Impairment and Skin Oxygen Availability to the Upper Limb During Standardized Arm Abduction in Patients With Suspected Thoracic Outlet Syndrome.

Authors:  Jeanne Hersant; Simon Lecoq; Pierre Ramondou; Xavier Papon; Mathieu Feuilloy; Pierre Abraham; Samir Henni
Journal:  Front Physiol       Date:  2022-02-11       Impact factor: 4.566

7.  Wrist Photoplethysmography Signal Quality Assessment for Reliable Heart Rate Estimate and Morphological Analysis.

Authors:  Serena Moscato; Stella Lo Giudice; Giulia Massaro; Lorenzo Chiari
Journal:  Sensors (Basel)       Date:  2022-08-04       Impact factor: 3.847

8.  An optimal filter for short photoplethysmogram signals.

Authors:  Yongbo Liang; Mohamed Elgendi; Zhencheng Chen; Rabab Ward
Journal:  Sci Data       Date:  2018-05-01       Impact factor: 6.444

9.  Alterations of blood pulsations parameters in carotid basin due to body position change.

Authors:  Alexei A Kamshilin; Tatiana V Krasnikova; Maxim A Volynsky; Serguei V Miridonov; Oleg V Mamontov
Journal:  Sci Rep       Date:  2018-09-12       Impact factor: 4.379

10.  A Wristwatch-Based Wireless Sensor Platform for IoT Health Monitoring Applications.

Authors:  Sanjeev Kumar; John L Buckley; John Barton; Melusine Pigeon; Robert Newberry; Matthew Rodencal; Adhurim Hajzeraj; Tim Hannon; Ken Rogers; Declan Casey; Donal O'Sullivan; Brendan O'Flynn
Journal:  Sensors (Basel)       Date:  2020-03-17       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.