Abstract

BACKGROUND: The importance of measuring aortic pulse wave velocity (PWVao), aortic augmentation index (Aix) and central systolic blood pressure (SBPao) has been shown under different clinical conditions; however, information on these parameters is hard to obtain. The aim of this study was to evaluate the accuracy of a new, easily applicable oscillometric device (Arteriograph), determining these parameters simultaneously, against invasive measurements.
METHODS: Aortic Aix, SBPao and PWVao were measured invasively during cardiac catheterization in 16, 55 and 22 cases, respectively, and compared with the values measured by the Arteriograph.
RESULTS: We found strong correlation between the invasively measured aortic Aix and the oscillometrically measured brachial Aix on either beat-to-beat or mean value per patient basis (r = 0.9, P < 0.001; r = 0.94, P < 0.001), which allowed the noninvasive calculation of the aortic Aix without using generalized transfer function. Similarly strong correlation (r = 0.95, P < 0.001) was found between the invasively measured and the noninvasively calculated central SBPao; furthermore, the BHS assessment of the paired differences fulfilled the 'B' grading. The PWVao values measured invasively and by Arteriograph were 9.41 ± 1.8 m/s and 9.46 ± 1.8 m/s, respectively (mean ± SD); furthermore, the Pearson's correlation was 0.91 (P < 0.001). The limits of agreement were 11.4% for aortic Aix and 1.59 m/s for PWVao.
CONCLUSION: Aix, SBPao and PWVao, measured oscillometrically, showed strong correlation with the invasively obtained values. The observed limits of agreement are encouragingly low for accepting the method for clinical use. Our results suggest that the PWVao values, measured by Arteriograph, are close to the true aortic PWV, determined invasively.

Entities:  

Mesh:

Year:  2010        PMID: 20651604     DOI: 10.1097/HJH.0b013e32833c8a1a

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  95 in total

Review 1.  Noninvasive studies of central aortic pressure.

Authors:  Michael F O'Rourke; Audrey Adji
Journal:  Curr Hypertens Rep       Date:  2012-02       Impact factor: 5.369

Review 2.  Meta-analysis of the comparative effects of different classes of antihypertensive agents on brachial and central systolic blood pressure, and augmentation index.

Authors:  Charlotte H Manisty; Alun D Hughes
Journal:  Br J Clin Pharmacol       Date:  2013-01       Impact factor: 4.335

3.  An automatic method for arterial pulse waveform recognition using KNN and SVM classifiers.

Authors:  Tânia Pereira; Joana S Paiva; Carlos Correia; João Cardoso
Journal:  Med Biol Eng Comput       Date:  2015-09-24       Impact factor: 2.602

Review 4.  Impact of Antihypertensive Agents on Central Systolic Blood Pressure and Augmentation Index: A Meta-Analysis.

Authors:  Tracey J McGaughey; Emily A Fletcher; Sachin A Shah
Journal:  Am J Hypertens       Date:  2015-08-19       Impact factor: 2.689

5.  Aortic pulse wave velocity is greater in peritoneal dialysis patients with lower dual energy X-ray absorptiometry (DXA) femoral neck bone mineral density.

Authors:  Kamonwan Tangvoraphonkchai; Andrew Davenport
Journal:  J Nephrol       Date:  2018-12-10       Impact factor: 3.902

Review 6.  How to Measure Arterial Stiffness in Humans.

Authors:  Patrick Segers; Ernst R Rietzschel; Julio A Chirinos
Journal:  Arterioscler Thromb Vasc Biol       Date:  2019-12-26       Impact factor: 8.311

7.  Aortic pulse wave velocity in individuals of Asian and African ancestry: the HELISUR study.

Authors:  Frederieke S Diemer; Se-Sergio M Baldew; Yentl C Haan; Fares A Karamat; Glenn P Oehlers; Gert A van Montfrans; Bert-Jan H van den Born; Ron J G Peters; Lenny M W Nahar-Van Venrooij; Lizzy M Brewster
Journal:  J Hum Hypertens       Date:  2018-12-19       Impact factor: 3.012

8.  Aortic Augmentation Index is Dependent on Bodyside in Healthy Young Subjects.

Authors:  Sandra Einstein; Kristjan Pilt; Merlin Palmar; Kalju Meigas; Margus Viigimaa
Journal:  High Blood Press Cardiovasc Prev       Date:  2019-08-16

9.  A Meta-analysis to Determine the Validity of Taking Blood Pressure Using the Indirect Cuff Method.

Authors:  Scott J Dankel; Minsoo Kang; Takashi Abe; Jeremy P Loenneke
Journal:  Curr Hypertens Rep       Date:  2019-02-07       Impact factor: 5.369

10.  Association Between Central-Peripheral Blood Pressure Amplification and Structural and Functional Cardiac Properties in Children, Adolescents, and Adults: Impact of the Amplification Parameter, Recording System and Calibration Scheme.

Authors:  Alejandro Díaz; Daniel Bia
Journal:  High Blood Press Cardiovasc Prev       Date:  2021-02-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.