BACKGROUND: Photoplethysmography (PPG) is routinely used to detect the blood pulse signal from skin tissue beds in clinics. However, the origin of the PPG signal remains controversial. The purpose of this study is to explore optical coherence tomography angiography (OCTA) to indicate pulsatile waveforms in the papillary plexus and dermal plexus separately under different hand elevations.
METHOD: Optical microangiography (OMAG) algorithm was used to obtain a 3D OCTA signals, from which the depth-resolved pulsatile blood flow signals were extracted from different skin vascular plexus. The systolic amplitude, crest time, and delta T were measured from the OCTA pulsatile signals when the hand was placed at the positions of 50 cm below, 0 cm, and 50 cm above the heart level.
RESULTS: The pulse signal integrated from all the depths has a similar waveform to that of the PPG and showed the same morphological change at different hand elevations. The pulsatile patterns from the papillary plexus and dermal plexus showed distinct morphological changes at different local blood pressure. Less amplitude difference was found from papillary plexus comparing to that of the dermal plexus. Crest time was found in an increasing trend in the OCTA pulsatile waveform from both plexuses when the arm was raised from the position below to above the heart level. In contrast, a decreasing trend of Delta T was detected in the dermal pulsatile but was not observed from that of the papillary plexus, indicating that vascular resistance associated with the arm elevations does not necessarily have the same effect on the two plexuses.
CONCLUSIONS: OCTA can provide depth-resolved pulsatile waveforms within different microvascular plexus within tissue skin beds. This technique could open doors to understanding the mechanisms of how blood flow changes at different skin circulatory plexus. 2021 Quantitative Imaging in Medicine and Surgery. All rights reserved.

Entities:  

Keywords:  Optical Microangiography (OMAG); Optical coherence tomography angiography (OCTA); Photoplethysmography (PPG); Pulsatile waveform

Year:  2021        PMID: 33654664      PMCID: PMC7829165          DOI: 10.21037/qims-20-778

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  37 in total

1.  Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes.

Authors:  J Allen; A Murray
Journal:  J Hum Hypertens       Date:  2002-10       Impact factor: 3.012

Review 2.  Arterial aging--hemodynamic changes and therapeutic options.

Authors:  Michel E Safar
Journal:  Nat Rev Cardiol       Date:  2010-08       Impact factor: 32.419

Review 3.  Methods and algorithms for optical coherence tomography-based angiography: a review and comparison.

Authors:  Anqi Zhang; Qinqin Zhang; Chieh-Li Chen; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2015-10       Impact factor: 3.170

4.  Noninvasive continuous monitoring of digital pulse waves during hemodialysis.

Authors:  Antje Burkert; Alexandra Scholze; Martin Tepel
Journal:  ASAIO J       Date:  2006 Mar-Apr       Impact factor: 2.872

5.  Quantitative Comparison of Photoplethysmographic Waveform Characteristics: Effect of Measurement Site.

Authors:  Vera Hartmann; Haipeng Liu; Fei Chen; Qian Qiu; Stephen Hughes; Dingchang Zheng
Journal:  Front Physiol       Date:  2019-03-05       Impact factor: 4.566

6.  Optical coherence tomography angiography-based capillary velocimetry.

Authors:  Ruikang K Wang; Qinqin Zhang; Yuandong Li; Shaozhen Song
Journal:  J Biomed Opt       Date:  2017-06-01       Impact factor: 3.170

7.  Highly efficient eigen decomposition based statistical optical microangiography.

Authors:  Qinqin Zhang; Jingang Wang; Ruikang K Wang
Journal:  Quant Imaging Med Surg       Date:  2016-10

8.  Non-invasive estimation of metabolic flux and blood flow in working muscle: effect of blood-tissue distribution.

Authors:  Nicola Lai; Gerald M Saidel; Matthew Iorio; Marco E Cabrera
Journal:  Adv Exp Med Biol       Date:  2009       Impact factor: 2.622

9.  Both body and arm position significantly influence blood pressure measurement.

Authors:  R T Netea; J W M Lenders; P Smits; Th Thien
Journal:  J Hum Hypertens       Date:  2003-07       Impact factor: 3.012

10.  Super-resolution spectral estimation of optical micro-angiography for quantifying blood flow within microcirculatory tissue beds in vivo.

Authors:  Siavash Yousefi; Jia Qin; Ruikang K Wang
Journal:  Biomed Opt Express       Date:  2013-06-27       Impact factor: 3.732

View more
  2 in total

1.  Interocular asymmetry of choroidal thickness and vascularity index measurements in normal eyes assessed by swept-source optical coherence tomography.

Authors:  Jie Lu; Hao Zhou; Yingying Shi; James Choe; Mengxi Shen; Liang Wang; Kelly Chen; Qinqin Zhang; William J Feuer; Giovanni Gregori; Philip J Rosenfeld; Ruikang K Wang
Journal:  Quant Imaging Med Surg       Date:  2022-01

Review 2.  Towards standardizing retinal optical coherence tomography angiography: a review.

Authors:  Danuta M Sampson; Adam M Dubis; Fred K Chen; Robert J Zawadzki; David D Sampson
Journal:  Light Sci Appl       Date:  2022-03-18       Impact factor: 17.782

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.