Literature DB >> 18185001

Monte Carlo investigation of collimator scatter of proton-therapy beams produced using the passive scattering method.

Uwe Titt1, Yuanshui Zheng, Oleg N Vassiliev, Wayne D Newhauser.   

Abstract

As a proton-therapy beam passes through the field-limiting aperture, some of the protons are scattered off the edges of the collimator. The edge-scattered protons can degrade the dose distribution in a patient or phantom, and these effects are difficult to model with analytical methods such as those available in treatment planning systems. The objective of this work was to quantify the dosimetric impact of edge-scattered protons for a representative variety of clinical treatment beams. The dosimetric impact was assessed using Monte Carlo simulations of proton beams from a contemporary treatment facility. The properties of the proton beams were varied, including the penetration range (6.4-28.5 cm), width of the spread-out Bragg peak (SOBP; 2-16 cm), field size (3 x 3 cm(2) to 15 x 15 cm(2)) and air gap, i.e. the distance between the collimator and the phantom (8-48 cm). The simulations revealed that the dosimetric impact of edge-scattered protons increased strongly with increasing range (dose increased by 6-20% with respect to the dose at the center of the spread-out Bragg peak), decreased strongly with increasing field size (dose changed by 2-20%), increased moderately with increasing air gap (dose increased by 2-6%) and increased weakly with increasing SOBP width (dose change <4%). In all cases examined, the effects were largest at shallow depths. We concluded that the dose deposited by edge-scattered protons can distort the dose proximal to the target with varying contributions due to the proton range, treatment field size, collimator position and thickness, and width of the SOBP. Our findings also suggest that accurate predictions of dose per monitor-unit calculations may require taking into account the dose from protons scattered from the edge of the patient-specific collimator, particularly for fields of small lateral size and deep depths.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18185001     DOI: 10.1088/0031-9155/53/2/014

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  26 in total

1.  An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle.

Authors:  Gabriel O Sawakuchi; Dragan Mirkovic; Luis A Perles; Narayan Sahoo; X Ron Zhu; George Ciangaru; Kazumichi Suzuki; Michael T Gillin; Radhe Mohan; Uwe Titt
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  Contribution to Neutron Fluence and Neutron Absorbed Dose from Double Scattering Proton Therapy System Components.

Authors:  A Pérez-Andújar; W D Newhauser; P M Deluca
Journal:  Nucl Technol       Date:  2009-01-01

3.  Dosimetric accuracy of planning and delivering small proton therapy fields.

Authors:  Bryan Bednarz; Juliane Daartz; Harald Paganetti
Journal:  Phys Med Biol       Date:  2010-11-19       Impact factor: 3.609

4.  Commissioning a passive-scattering proton therapy nozzle for accurate SOBP delivery.

Authors:  M Engelsman; H M Lu; D Herrup; M Bussiere; H M Kooy
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

5.  Simplified estimation method for dose distributions around field junctions in proton craniospinal irradiation.

Authors:  Haruo Yamashita; Yuki Kase; Shigeyuki Murayama
Journal:  Radiol Phys Technol       Date:  2016-09-01

6.  DICOM-RT Ion interface to utilize MC simulations in routine clinical workflow for proton pencil beam radiotherapy.

Authors:  Jungwook Shin; Hanne M Kooy; Harald Paganetti; Benjamin Clasie
Journal:  Phys Med       Date:  2020-05-07       Impact factor: 2.685

7.  REDUCING STRAY RADIATION DOSE FOR A PEDIATRIC PATIENT RECEIVING PROTON CRANIOSPINAL IRRADIATION.

Authors:  Phillip J Taddei; Dragan Mirkovic; Jonas D Fontenot; Annelise Giebeler; Yuanshui Zheng; Uwe Titt; Shiao Woo; Wayne D Newhauser
Journal:  Nucl Technol       Date:  2009-10-01

8.  Neutron production from beam-modifying devices in a modern double scattering proton therapy beam delivery system.

Authors:  Angélica Pérez-Andújar; Wayne D Newhauser; Paul M Deluca
Journal:  Phys Med Biol       Date:  2009-01-16       Impact factor: 3.609

9.  Assessment of the accuracy of an MCNPX-based Monte Carlo simulation model for predicting three-dimensional absorbed dose distributions.

Authors:  U Titt; N Sahoo; X Ding; Y Zheng; W D Newhauser; X R Zhu; J C Polf; M T Gillin; R Mohan
Journal:  Phys Med Biol       Date:  2008-07-31       Impact factor: 3.609

10.  Reducing stray radiation dose to patients receiving passively scattered proton radiotherapy for prostate cancer.

Authors:  Phillip J Taddei; Jonas D Fontenot; Yuanshui Zheng; Dragan Mirkovic; Andrew K Lee; Uwe Titt; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2008-03-27       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.