Literature DB >> 25662439

Long-term durability of bioprosthetic aortic valves: implications from 12,569 implants.

Douglas R Johnston1, Edward G Soltesz2, Nakul Vakil2, Jeevanantham Rajeswaran3, Eric E Roselli2, Joseph F Sabik2, Nicholas G Smedira2, Lars G Svensson2, Bruce W Lytle2, Eugene H Blackstone4.   

Abstract

BACKGROUND: Increased life expectancy and younger patients' desire to avoid lifelong anticoagulation requires a better understanding of bioprosthetic valve failure. This study evaluates risk factors associated with explantation for structural valve deterioration (SVD) in a long-term series of Carpentier-Edwards PERIMOUNT aortic valves (AV).
METHODS: From June 1982 to January 2011, 12,569 patients underwent AV replacement with Edwards Lifesciences Carpentier-Edwards PERIMOUNT stented bovine pericardial prostheses, models 2700PM (n = 310) or 2700 (n = 12,259). Mean age was 71 ± 11 years (range, 18 to 98 years). 93% had native AV disease, 48% underwent concomitant coronary artery bypass grafting, and 26% had additional valve surgery. There were 81,706 patient-years of systematic follow-up data available for analysis. Demographics, intraoperative variables, and 27,386 echocardiographic records were used to identify risks for explant for SVD and assess longitudinal changes in transprosthesis gradients using time-varying covariable analyses.
RESULTS: Three hundred fifty-four explants were performed, with 41% related to endocarditis and 44% to SVD. Actuarial estimates of explant for SVD at 10 and 20 years were 1.9% and 15% overall, respectively, and in patients younger than 60 years, 5.6% and 46%, respectively. Younger age (p < 0.0001), lipid-lowering drugs (p = 0.002), prosthesis-patient mismatch (p = 0.001), and higher postoperative peak and mean AV gradients were associated with explant for SVD (p < 0.0001). The effect of gradient on SVD was greatest in patients younger than 60 years.
CONCLUSIONS: Durability of the Carpentier-Edwards PERIMOUNT aortic valve is excellent even in younger patients. Explant for SVD is related to gradient at implantation, especially in younger patients. Strategies to reduce early postoperative AV gradients, such as root enlargement or more efficient prostheses, should be considered.
Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 25662439      PMCID: PMC5132179          DOI: 10.1016/j.athoracsur.2014.10.070

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  17 in total

1.  Age and valve size effect on the long-term durability of the Carpentier-Edwards aortic pericardial bioprosthesis.

Authors:  M K Banbury; D M Cosgrove; J A White; E H Blackstone; R W Frater; J E Okies
Journal:  Ann Thorac Surg       Date:  2001-09       Impact factor: 4.330

2.  Hemodynamic stability during 17 years of the Carpentier-Edwards aortic pericardial bioprosthesis.

Authors:  Michael K Banbury; Delos M Cosgrove; James D Thomas; Eugene H Blackstone; Jeevanantham Rajeswaran; J Edward Okies; Robert M Frater
Journal:  Ann Thorac Surg       Date:  2002-05       Impact factor: 4.330

3.  Late outcomes for aortic valve replacement with the Carpentier-Edwards pericardial bioprosthesis: up to 17-year follow-up in 1,000 patients.

Authors:  R Scott McClure; Narendren Narayanasamy; Esther Wiegerinck; Stuart Lipsitz; Ann Maloney; John G Byrne; Sary F Aranki; Gregory S Couper; Lawrence H Cohn
Journal:  Ann Thorac Surg       Date:  2010-05       Impact factor: 4.330

4.  ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing Committee to Revise the 1998 guidelines for the management of patients with valvular heart disease) developed in collaboration with the Society of Cardiovascular Anesthesiologists endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons.

Authors:  Robert O Bonow; Blase A Carabello; Kanu Chatterjee; Antonio C de Leon; David P Faxon; Michael D Freed; William H Gaasch; Bruce Whitney Lytle; Rick A Nishimura; Patrick T O'Gara; Robert A O'Rourke; Catherine M Otto; Pravin M Shah; Jack S Shanewise; Sidney C Smith; Alice K Jacobs; Cynthia D Adams; Jeffrey L Anderson; Elliott M Antman; Valentin Fuster; Jonathan L Halperin; Loren F Hiratzka; Sharon A Hunt; Bruce W Lytle; Rick Nishimura; Richard L Page; Barbara Riegel
Journal:  J Am Coll Cardiol       Date:  2006-08-01       Impact factor: 24.094

5.  A bootstrap resampling procedure for model building: application to the Cox regression model.

Authors:  W Sauerbrei; M Schumacher
Journal:  Stat Med       Date:  1992-12       Impact factor: 2.373

6.  Aortic valve replacement with the Mitroflow pericardial bioprosthesis: durability results up to 21 years.

Authors:  Charles A Yankah; Miralem Pasic; Michele Musci; Julia Stein; Christine Detschades; Henryk Siniawski; Roland Hetzer
Journal:  J Thorac Cardiovasc Surg       Date:  2008-07-14       Impact factor: 5.209

7.  Fifteen-year experience with the mitral Carpentier-Edwards PERIMOUNT pericardial bioprosthesis.

Authors:  M A Marchand; M R Aupart; R Norton; I R Goldsmith; L C Pelletier; M Pellerin; T Dubiel; W J Daenen; P Herijgers; F P Casselman; M P Holden; T E David
Journal:  Ann Thorac Surg       Date:  2001-05       Impact factor: 4.330

8.  Ventricular hypertrophy and left atrial dilatation persist and are associated with reduced survival after valve replacement for aortic stenosis.

Authors:  Jocelyn M Beach; Tomislav Mihaljevic; Jeevanantham Rajeswaran; Thomas Marwick; Samuel T Edwards; Edward R Nowicki; James Thomas; Lars G Svensson; Brian Griffin; A Marc Gillinov; Eugene H Blackstone
Journal:  J Thorac Cardiovasc Surg       Date:  2013-01-11       Impact factor: 5.209

9.  A multiphase non-linear mixed effects model: An application to spirometry after lung transplantation.

Authors:  Jeevanantham Rajeswaran; Eugene H Blackstone
Journal:  Stat Methods Med Res       Date:  2016-07-11       Impact factor: 3.021

10.  Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: influence of age, obesity, and left ventricular dysfunction.

Authors:  Dania Mohty; Jean G Dumesnil; Najmeddine Echahidi; Patrick Mathieu; François Dagenais; Pierre Voisine; Philippe Pibarot
Journal:  J Am Coll Cardiol       Date:  2009-01-06       Impact factor: 24.094

View more
  61 in total

Review 1.  Valve durability after transcatheter aortic valve implantation.

Authors:  Akash Kataruka; Catherine M Otto
Journal:  J Thorac Dis       Date:  2018-11       Impact factor: 2.895

Review 2.  [Surgical treatment of aortic valve stenosis].

Authors:  O J Liakopoulos; J Merkle; T Wahlers; Y-H Choi
Journal:  Herz       Date:  2017-09       Impact factor: 1.443

Review 3.  Durability of prostheses for transcatheter aortic valve implantation.

Authors:  Mani Arsalan; Thomas Walther
Journal:  Nat Rev Cardiol       Date:  2016-04-07       Impact factor: 32.419

Review 4.  Evolution of surgical therapy for Stanford acute type A aortic dissection.

Authors:  Peter Chiu; D Craig Miller
Journal:  Ann Cardiothorac Surg       Date:  2016-07

5.  A mechanical heart valve is the best choice.

Authors:  Iqbal H Jaffer; Richard P Whitlock
Journal:  Heart Asia       Date:  2016-04-28

6.  Aortic valve replacement after bypass surgery: surgical (SAVR) or transcatheter (TAVR).

Authors:  Bruce W Lytle
Journal:  J Thorac Dis       Date:  2017-09       Impact factor: 2.895

7.  Transcatheter aortic valve replacement in intermediate and low risk patients-clinical evidence.

Authors:  Sameer Arora; John P Vavalle
Journal:  Ann Cardiothorac Surg       Date:  2017-09

8.  Optimizations of stent and tissue leaflets in a new surgical bovine pericardial valve.

Authors:  Jinmiao Chen; Jun Yang; Li Zhang; Wenrui Ma; Shuyang Lu; Chunsheng Wang; Tao Hong
Journal:  J Thorac Dis       Date:  2019-11       Impact factor: 2.895

9.  Opening-closing pattern of four pericardial prostheses: results from an in vitro study of leaflet kinematics.

Authors:  Giordano Tasca; Gianfranco Beniamino Fiore; Andrea Mangini; Claudia Romagnoni; Amando Gamba; Alberto Redaelli; Carlo Antona; Riccardo Vismara
Journal:  J Artif Organs       Date:  2016-05-26       Impact factor: 1.731

10.  Characterization of immunogenic Neu5Gc in bioprosthetic heart valves.

Authors:  Eliran Moshe Reuven; Shani Leviatan Ben-Arye; Tal Marshanski; Michael E Breimer; Hai Yu; Imen Fellah-Hebia; Jean-Christian Roussel; Cristina Costa; Manuel Galiñanes; Rafael Mañez; Thierry Le Tourneau; Jean-Paul Soulillou; Emanuele Cozzi; Xi Chen; Vered Padler-Karavani
Journal:  Xenotransplantation       Date:  2016-09-09       Impact factor: 3.907

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.