Literature DB >> 12025820

Hemodynamic stability during 17 years of the Carpentier-Edwards aortic pericardial bioprosthesis.

Michael K Banbury1, Delos M Cosgrove, James D Thomas, Eugene H Blackstone, Jeevanantham Rajeswaran, J Edward Okies, Robert M Frater.   

Abstract

BACKGROUND: Long-term stability of the hemodynamic performance of commercially available Carpentier-Edwards stented bovine pericardial aortic bioprostheses (Perimount RSR) is unknown. To anticipate the fate of this bioprosthesis, we examined its hemodynamic performance up to 17 years using echocardiographic studies in a Premarket Approval cohort.
METHODS: Of 267 patients at four institutions in the Premarket Approval cohort, 85 had a total of 168 echocardiographic studies during a 17-year period of yearly follow-up examinations. These were reviewed and quantified in a core echocardiographic facility. Longitudinal data analysis was used to account for repeated, censored data.
RESULTS: Mean transvalvular gradient was inversely related to prosthesis size (p = 0.01), and possibly (p = 0.06) increased somewhat during the first 10 years of follow-up, then stabilized. Effective orifice area was larger in larger valve sizes (p = 0.01), declined somewhat during the first 10 years, and then began to increase again. Ejection fraction declined minimally (p = 0.2). In contrast to the rather stable hemodynamics, aortic regurgitation steadily increased from none to 1 to 2+ (p = 0.005), but rarely (< 10% at 17 years) progressed to 3+ or 4+.
CONCLUSIONS: The Carpentier-Edwards aortic pericardial bioprosthesis can be anticipated to have an acceptable long-term transvalvular gradient and effective orifice size that will change trivially up to 17 years after implantation. Mild aortic regurgitation will develop progressively. This anticipated hemodynamic resilience supports continued clinical use of the Perimount Carpentier-Edwards bovine pericardial stented bioprosthesis.

Entities:  

Mesh:

Year:  2002        PMID: 12025820     DOI: 10.1016/s0003-4975(02)03445-8

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  14 in total

1.  Carpentier-Edwards pericardial aortic valve in middle-aged patients: comparison with the St. Jude Medical valve.

Authors:  Yoshimasa Sakamoto; Kazuhiro Hashimoto; Hiroshi Okuyama; Shinichi Ishii; Takahiro Inoue; Katsushi Kinouchi; Takayuki Abe
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2005-09

2.  Long-term durability of bioprosthetic aortic valves: implications from 12,569 implants.

Authors:  Douglas R Johnston; Edward G Soltesz; Nakul Vakil; Jeevanantham Rajeswaran; Eric E Roselli; Joseph F Sabik; Nicholas G Smedira; Lars G Svensson; Bruce W Lytle; Eugene H Blackstone
Journal:  Ann Thorac Surg       Date:  2015-02-04       Impact factor: 4.330

3.  Aortic valve replacement vs. transcatheter aortic valve implantation: Patient selection.

Authors:  Jian Ye; Jia Lin Soon; John Webb
Journal:  Ann Cardiothorac Surg       Date:  2012-07

4.  Primary echocardiographic results of the Carpentier-Edwards Perimount Magna.

Authors:  Hiroki Mizoguchi; Masayuki Sakaki; Kazushige Inoue; Yasuhiko Kobayashi; Takashi Iwata; Yasuo Suehiro; Takuya Miura
Journal:  J Med Ultrason (2001)       Date:  2012-04-05       Impact factor: 1.314

5.  Outcomes of surgical aortic valve replacement using Carpentier-Edwards PERIMOUNT bioprosthesis series in elderly patients with severe aortic valve stenosis: a retrospective cohort study.

Authors:  Naritomo Nishioka; Akira Yamada; Kosuke Ujihira; Yutaka Iba; Ryushi Maruyama; Eiichiro Hatta; Yoshihiko Kurimoto; Katsuhiko Nakanishi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-08-04

6.  Twelve-year experience with the Carpentier-Edwards pericardial aortic valve at a single Japanese center.

Authors:  Koichi Arinaga; Shuji Fukunaga; Hiroshi Tomoeda; Hidetsugu Hori; Tomohiro Ueda; Ryusuke Mori; Shigeaki Aoyagi
Journal:  J Artif Organs       Date:  2011-05-03       Impact factor: 1.731

7.  Clinical and echocardiographic outcomes after implantation of the Trifecta aortic bioprosthesis: an initial single-centre experience.

Authors:  Angelo M Dell'Aquila; Dominik Schlarb; Stefan R B Schneider; Jürgen R Sindermann; Andreas Hoffmeier; Gerrit Kaleschke; Sven Martens; Andreas Rukosujew
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-11-15

Review 8.  What is new in the 2006 ACC/AHA guidelines on valvular heart disease?

Authors:  Blase A Carabello
Journal:  Curr Cardiol Rep       Date:  2008-03       Impact factor: 2.931

9.  Homografts in aortic position: does blood group incompatibility have an impact on patient outcomes?

Authors:  Ferdinand Vogt; Bernhard Michael Böll; Anne-Laure Boulesteix; Eckehard Kilian; Giuseppe Santarpino; Bruno Reichart; Christoph Schmitz
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-02-06

10.  A multiphase non-linear mixed effects model: An application to spirometry after lung transplantation.

Authors:  Jeevanantham Rajeswaran; Eugene H Blackstone
Journal:  Stat Methods Med Res       Date:  2016-07-11       Impact factor: 3.021

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.