Literature DB >> 30505545

Valve durability after transcatheter aortic valve implantation.

Akash Kataruka1, Catherine M Otto1.   

Abstract

Transcatheter aortic valve implantation (TAVI) is a minimally invasive procedure to treat severe symptomatic aortic stenosis. While the TAVI procedure can be performed safely and provide excellent 5-year results, little is known about long-term durability. TAVI valves are composed of bioprosthetic leaflets are prone to deterioration, which are categorized as structural valve deterioration (SVD) and non-SVD. SVD refers to an intrinsic pathology of the leaflets or stent structure with mechanisms that include leaflet calcification, leaflet tear, stent fracture, or stent creep. Non-SVD processes include valve thrombosis, infective endocarditis and patient prosthesis mismatch. TAVI valves degenerate by similar mechanisms as bioprosthetic surgical aortic valves. Unique mechanisms that contribute to TAVI degeneration include valve crimpling, balloon expansion, stent under-expansion and valve thrombosis. The absence of a universally accepted definition of SVD poses a challenge in estimating valve durability. Traditional surgical bioprosthetic aortic valves have demonstrated excellent durability with clinically relevant SVD of 6.6% at 10-year follow up. Long-term durability of TAVI valves, however, remain poorly defined. From meta-analysis TAVI trials, SVD was estimated at 7% at 5 years. With iterative improvements in TAVI valve construction and deployment techniques, long-term durability may improve. Until long-term outcomes are better understood, TAVI should be used with caution in younger patients.

Entities:  

Keywords:  Transcatheter aortic valve implantation durability (TAVI durability); aortic stenosis; long-term outcomes; structural valve deterioration; valve hemodynamics

Year:  2018        PMID: 30505545      PMCID: PMC6242919          DOI: 10.21037/jtd.2018.07.38

Source DB:  PubMed          Journal:  J Thorac Dis        ISSN: 2072-1439            Impact factor:   2.895


  56 in total

1.  Simulated elliptical bioprosthetic valve deformation: implications for asymmetric transcatheter valve deployment.

Authors:  Wei Sun; Kewei Li; Eric Sirois
Journal:  J Biomech       Date:  2010-12-01       Impact factor: 2.712

2.  Long-term durability of bioprosthetic aortic valves: implications from 12,569 implants.

Authors:  Douglas R Johnston; Edward G Soltesz; Nakul Vakil; Jeevanantham Rajeswaran; Eric E Roselli; Joseph F Sabik; Nicholas G Smedira; Lars G Svensson; Bruce W Lytle; Eugene H Blackstone
Journal:  Ann Thorac Surg       Date:  2015-02-04       Impact factor: 4.330

3.  Transcatheter versus surgical aortic-valve replacement in high-risk patients.

Authors:  Craig R Smith; Martin B Leon; Michael J Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; Mathew Williams; Todd Dewey; Samir Kapadia; Vasilis Babaliaros; Vinod H Thourani; Paul Corso; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Jodi J Akin; William N Anderson; Duolao Wang; Stuart J Pocock
Journal:  N Engl J Med       Date:  2011-06-05       Impact factor: 91.245

4.  Long-Term Outcomes Following Surgical Aortic Bioprosthesis Implantation.

Authors:  Tania Rodriguez-Gabella; Pierre Voisine; François Dagenais; Siamak Mohammadi; Jean Perron; Eric Dumont; Rishi Puri; Lluis Asmarats; Mélanie Côté; Sebastien Bergeron; Philippe Pibarot; Josep Rodés-Cabau
Journal:  J Am Coll Cardiol       Date:  2018-04-03       Impact factor: 24.094

Review 5.  Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document.

Authors:  A Pieter Kappetein; Stuart J Head; Philippe Généreux; Nicolo Piazza; Nicolas M van Mieghem; Eugene H Blackstone; Thomas G Brott; David J Cohen; Donald E Cutlip; Gerrit-Anne van Es; Rebecca T Hahn; Ajay J Kirtane; Mitchell W Krucoff; Susheel Kodali; Michael J Mack; Roxana Mehran; Josep Rodés-Cabau; Pascal Vranckx; John G Webb; Stephan Windecker; Patrick W Serruys; Martin B Leon
Journal:  J Am Coll Cardiol       Date:  2012-10-09       Impact factor: 24.094

6.  Mechanism of efficacy of 2-amino oleic acid for inhibition of calcification of glutaraldehyde-pretreated porcine bioprosthetic heart valves.

Authors:  W Chen; F J Schoen; R J Levy
Journal:  Circulation       Date:  1994-07       Impact factor: 29.690

7.  Transcatheter aortic valve implantation in failed bioprosthetic surgical valves.

Authors:  Danny Dvir; John G Webb; Sabine Bleiziffer; Miralem Pasic; Ron Waksman; Susheel Kodali; Marco Barbanti; Azeem Latib; Ulrich Schaefer; Josep Rodés-Cabau; Hendrik Treede; Nicolo Piazza; David Hildick-Smith; Dominique Himbert; Thomas Walther; Christian Hengstenberg; Henrik Nissen; Raffi Bekeredjian; Patrizia Presbitero; Enrico Ferrari; Amit Segev; Arend de Weger; Stephan Windecker; Neil E Moat; Massimo Napodano; Manuel Wilbring; Alfredo G Cerillo; Stephen Brecker; Didier Tchetche; Thierry Lefèvre; Federico De Marco; Claudia Fiorina; Anna Sonia Petronio; Rui C Teles; Luca Testa; Jean-Claude Laborde; Martin B Leon; Ran Kornowski
Journal:  JAMA       Date:  2014-07       Impact factor: 56.272

8.  Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database.

Authors:  James M Brown; Sean M O'Brien; Changfu Wu; Jo Ann H Sikora; Bartley P Griffith; James S Gammie
Journal:  J Thorac Cardiovasc Surg       Date:  2009-01       Impact factor: 5.209

9.  Long-term durability and haemodynamic performance of a self-expanding transcatheter heart valve beyond five years after implantation: a prospective observational study applying the standardised definitions of structural deterioration and valve failure.

Authors:  Erik W Holy; Julia Kebernik; Mohammad Abdelghani; Simon F Stämpfli; Jens Hellermann; Abdelhakim Allali; Mohamed El-Mawardy; Susanne Sachse; Thomas F Lüscher; Felix C Tanner; Gert Richardt; Mohamed Abdel-Wahab
Journal:  EuroIntervention       Date:  2018-07-20       Impact factor: 6.534

Review 10.  Recommendations for the imaging assessment of prosthetic heart valves: a report from the European Association of Cardiovascular Imaging endorsed by the Chinese Society of Echocardiography, the Inter-American Society of Echocardiography, and the Brazilian Department of Cardiovascular Imaging.

Authors:  Patrizio Lancellotti; Philippe Pibarot; John Chambers; Thor Edvardsen; Victoria Delgado; Raluca Dulgheru; Mauro Pepi; Bernard Cosyns; Mark R Dweck; Madalina Garbi; Julien Magne; Koen Nieman; Raphael Rosenhek; Anne Bernard; Jorge Lowenstein; Marcelo Luiz Campos Vieira; Arnaldo Rabischoffsky; Rodrigo Hernández Vyhmeister; Xiao Zhou; Yun Zhang; Jose-Luis Zamorano; Gilbert Habib
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2016-05-03       Impact factor: 6.875

View more
  6 in total

1.  A 43-year-old functional Starr-Edwards ball and cage mechanical aortic valve.

Authors:  Samuel Powell; Ravi Choxi; Sampath Gunda; Ion S Jovin
Journal:  Gen Thorac Cardiovasc Surg       Date:  2020-05-14

2.  Predictive Model for Thrombus Formation After Transcatheter Valve Replacement.

Authors:  Hoda Hatoum; Shelly Singh-Gryzbon; Fateme Esmailie; Philipp Ruile; Franz-Josef Neumann; Philipp Blanke; Vinod H Thourani; Ajit P Yoganathan; Lakshmi Prasad Dasi
Journal:  Cardiovasc Eng Technol       Date:  2021-12-02       Impact factor: 2.495

3.  Preoperative hypomagnesemia as a possible predictive factor for postoperative increase of transvalvular pressure gradient in hemodialysis patients treated with transcatheter aortic valve implantation.

Authors:  Satoshi Masuyama; Masayuki Mizui; Koichi Maeda; Kazuo Shimamura; Yusuke Sakaguchi; Masashi Morita; Toru Kuratani; Isamu Mizote; Daisuke Nakamura; Yasushi Sakata; Yoshiki Sawa; Shigeru Miyagawa; Yoshitaka Isaka
Journal:  Ren Fail       Date:  2022-12       Impact factor: 3.222

4.  Preoperative Anemia and Postoperative Mortality in Patients with Aortic Stenosis Treated with Transcatheter Aortic Valve Implantation (TAVI): A Systematic Review and Meta-Analysis.

Authors:  Zhenqian Lv; Baoguo Zhou; Chunyue Yang; Haiping Wang
Journal:  Med Sci Monit       Date:  2019-09-27

Review 5.  Transcatheter Bioprosthetic Aortic Valve Dysfunction: What We Know So Far.

Authors:  Fadi Sawaya; Troels H Jørgensen; Lars Søndergaard; Ole De Backer
Journal:  Front Cardiovasc Med       Date:  2019-10-04

6.  Noncalcific Mechanisms of Bioprosthetic Structural Valve Degeneration.

Authors:  Matteo Marro; Alexander P Kossar; Yingfei Xue; Antonio Frasca; Robert J Levy; Giovanni Ferrari
Journal:  J Am Heart Assoc       Date:  2021-01-26       Impact factor: 5.501

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.