Age and valve size effect on the long-term durability of the Carpentier-Edwards aortic pericardial bioprosthesis.

M K Banbury1, D M Cosgrove, J A White, E H Blackstone, R W Frater, J E Okies.   

Abstract

BACKGROUND: Bioprosthesis durability decreases with time and younger age. However, the time-scale and determinants of durability of the aortic Carpentier-Edwards stented bovine pericardial prosthesis are incompletely characterized.
METHODS: Between September 1981 and January 1984, 267 patients underwent implantation of the pericardial aortic prosthesis at four centers. Mean age at implant was 65 +/- 12 years (range 21 to 86 years). Follow-up averaged 12 +/- 4.5 years. The primary end point was explant for structural valve dysfunction (SVD), which was analyzed multivariably in the context of death as a competing risk.
RESULTS: Freedom from explant due to SVD was 99%, 94%, and 77% at 5, 10, and 15 years. Risk of SVD increased exponentially with time and younger age (p = 0.0001) at implantation; an increased risk of small valve size was not reliably demonstrated (p = 0.1). Considering the competing risk of death, patients aged 65 years or older had a less than 10% chance of explant for SVD by 15 years.
CONCLUSIONS: Durability of this stented pericardial aortic bioprosthesis is excellent and justifies its use in patients aged 65 or older.

Entities:  

Mesh:

Year:  2001        PMID: 11565653     DOI: 10.1016/s0003-4975(01)02992-7

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  23 in total

1.  Carpentier-Edwards pericardial aortic valve in middle-aged patients: comparison with the St. Jude Medical valve.

Authors:  Yoshimasa Sakamoto; Kazuhiro Hashimoto; Hiroshi Okuyama; Shinichi Ishii; Takahiro Inoue; Katsushi Kinouchi; Takayuki Abe
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2005-09

2.  Reconstruction of bicuspid aortic valves. Surgical tool or toy?

Authors:  H-J Schäfers
Journal:  Z Kardiol       Date:  2005-07

3.  Long-term durability of bioprosthetic aortic valves: implications from 12,569 implants.

Authors:  Douglas R Johnston; Edward G Soltesz; Nakul Vakil; Jeevanantham Rajeswaran; Eric E Roselli; Joseph F Sabik; Nicholas G Smedira; Lars G Svensson; Bruce W Lytle; Eugene H Blackstone
Journal:  Ann Thorac Surg       Date:  2015-02-04       Impact factor: 4.330

Review 4.  When is concomitant aortic valve replacement indicated in patients with mild to moderate stenosis undergoing coronary revascularization?

Authors:  A Marc Gillinov; Mario J Garcia
Journal:  Curr Cardiol Rep       Date:  2005-03       Impact factor: 2.931

5.  Exercise stress echocardiography in patients with aortic stenosis: impact of baseline diastolic dysfunction and functional capacity on mortality and aortic valve replacement.

Authors:  Andrew N Rassi; Wael Aljaroudi; Sahar Naderi; M Chadi Alraies; Venu Menon; Leonardo Rodriguez; Richard Grimm; Brian Griffin; Wael A Jaber
Journal:  Cardiovasc Diagn Ther       Date:  2013-12

6.  Anticoagulant independent mechanical heart valves: viable now or still a distant holy grail.

Authors:  Aurelio Chaux; Richard J Gray; Jonathan C Stupka; Michael R Emken; Lawrence N Scotten; Rolland Siegel
Journal:  Ann Transl Med       Date:  2016-12

Review 7.  Valvular heart disease: diagnosis and management.

Authors:  Kameswari Maganti; Vera H Rigolin; Maurice Enriquez Sarano; Robert O Bonow
Journal:  Mayo Clin Proc       Date:  2010-05       Impact factor: 7.616

Review 8.  Durability of prostheses for transcatheter aortic valve implantation.

Authors:  Mani Arsalan; Thomas Walther
Journal:  Nat Rev Cardiol       Date:  2016-04-07       Impact factor: 32.419

9.  Choice of prosthetic heart valve in a developing country.

Authors:  Shiv Kumar Choudhary; Sachin Talwar; Balram Airan
Journal:  Heart Asia       Date:  2016-04-28

10.  Missing leaflet: a rare cause of structural deterioration of a bovine pericardial aortic bioprosthesis-report of a case.

Authors:  Yoshinobu Nakamura; Yoshikazu Fujiwara; Suguru Shiraya; Munehiro Saiki; Shingo Harada; Yuichiro Kishimoto; Takeshi Onohara; Yuki Otsuki; Motonobu Nishimura
Journal:  Surg Today       Date:  2013-05-23       Impact factor: 2.549

View more