Literature DB >> 20417753

Late outcomes for aortic valve replacement with the Carpentier-Edwards pericardial bioprosthesis: up to 17-year follow-up in 1,000 patients.

R Scott McClure1, Narendren Narayanasamy, Esther Wiegerinck, Stuart Lipsitz, Ann Maloney, John G Byrne, Sary F Aranki, Gregory S Couper, Lawrence H Cohn.   

Abstract

BACKGROUND: This study reviews a single institution experience with the Carpentier-Edwards pericardial aortic valve bioprosthesis, concentrating on late outcomes.
METHODS: From December 1991 to June 2002, 1,000 patients underwent aortic valve replacement with the Carpentier-Edwards pericardial valve (mean follow-up 6.01 +/- 3.56 years). The institutional database was reviewed. Follow-up data were acquired through telephone interviews and mail-in questionnaires. Time-to-event analyses were performed by the Kaplan-Meier method. Mean age was 74.1 years; 545 patients (54.5%) were male. Mean preoperative ejection fraction was 52.5%. Isolated aortic valve replacement occurred in 372 cases (37.2%). Combined aortic valve replacement with coronary artery bypass grafting occurred in 443 cases (44.3%). The remaining 185 patients (18.5%) underwent complex procedures with concomitant mitral, tricuspid, or arch repair. One hundred forty patients (14.0%) had prior aortic valve surgery. Follow-up was 99.4% complete.
RESULTS: Overall operative mortality was 7.2% (72 of 1,000). There were 503 late deaths (50.3%). Age-stratified survival at 15 years was 43.7% for patients less than 65 years of age; 18.2% for patients aged 65 to 75; and 9.4% for patients aged more than 75 years. There were 26 failed bioprostheses (2.6%) requiring reoperation. Structural valve deterioration was the cause in 13 of 26 cases (50%), endocarditis in 11 of 26 (42%), and perivalvular leak in 2 of 26 (7.6%). Age-stratified freedom from reoperation due to structural valve deterioration at 15 years was 34.7% for patients less than 65 years of age; 89.4% for patients aged 65 to 75; and 99.5% for patients aged more than 75 years.
CONCLUSIONS: The Carpentier-Edwards pericardial bioprosthesis shows long-term durability with low rates of structural failure. Copyright (c) 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20417753     DOI: 10.1016/j.athoracsur.2010.01.046

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  34 in total

1.  Long-term durability of bioprosthetic aortic valves: implications from 12,569 implants.

Authors:  Douglas R Johnston; Edward G Soltesz; Nakul Vakil; Jeevanantham Rajeswaran; Eric E Roselli; Joseph F Sabik; Nicholas G Smedira; Lars G Svensson; Bruce W Lytle; Eugene H Blackstone
Journal:  Ann Thorac Surg       Date:  2015-02-04       Impact factor: 4.330

2.  Pulmonary valve replacement long after repair of tetralogy of Fallot.

Authors:  Yuichi Shiokawa; Hiromichi Sonoda; Yoshihisa Tanoue; Takahiro Nishida; Atsuhiro Nakashima; Ryuji Tominaga
Journal:  Gen Thorac Cardiovasc Surg       Date:  2012-05-08

Review 3.  The Use of Biological Heart Valves.

Authors:  Sami Kueri; Fabian A Kari; Rafael Ayala Fuentes; Hans-Hinrich Sievers; Friedhelm Beyersdorf; Wolfgang Bothe
Journal:  Dtsch Arztebl Int       Date:  2019-06-21       Impact factor: 5.594

Review 4.  Surgical Treatment of Valvular Heart Disease: Overview of Mechanical and Tissue Prostheses, Advantages, Disadvantages, and Implications for Clinical Use.

Authors:  Amy G Fiedler; George Tolis
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-02-05

5.  Surgical technique of double valve replacement in a patient with osteogenesis imperfecta.

Authors:  Mizuki Sumi; Tsuneo Ariyoshi; Seiji Matsukuma; Shun Nakaji; Koji Hashizume; Naoe Kinoshita; Kiyoyuki Eishi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2014-06-11

Review 6.  Selection of prosthetic valve and evidence--need for the development of Japan's own guidelines.

Authors:  Akira Sezai; Motomi Shiono
Journal:  Ann Thorac Cardiovasc Surg       Date:  2015-06-09       Impact factor: 1.520

Review 7.  Durability of prostheses for transcatheter aortic valve implantation.

Authors:  Mani Arsalan; Thomas Walther
Journal:  Nat Rev Cardiol       Date:  2016-04-07       Impact factor: 32.419

8.  Noninferiority of Shanghai Cingular biotech's bovine pericardial valve preclinical study in juvenile ovine model.

Authors:  Jin-Miao Chen; Yu Ding; Shu-Yang Lu; Sun Pan; Mieradilijiang Abudupataer; Tao Hong; Chun-Sheng Wang
Journal:  J Thorac Dis       Date:  2016-06       Impact factor: 2.895

9.  Outcomes of surgical aortic valve replacement using Carpentier-Edwards PERIMOUNT bioprosthesis series in elderly patients with severe aortic valve stenosis: a retrospective cohort study.

Authors:  Naritomo Nishioka; Akira Yamada; Kosuke Ujihira; Yutaka Iba; Ryushi Maruyama; Eiichiro Hatta; Yoshihiko Kurimoto; Katsuhiko Nakanishi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-08-04

Review 10.  Polymeric trileaflet prosthetic heart valves: evolution and path to clinical reality.

Authors:  Thomas E Claiborne; Marvin J Slepian; Syed Hossainy; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2012-11       Impact factor: 3.166

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.