Attenuation-based size metric for estimating organ dose to patients undergoing tube current modulated CT exams.

Maryam Bostani1, Kyle McMillan1, Peiyun Lu1, Hyun J Kim1, Chris H Cagnon1, John J DeMarco2, Michael F McNitt-Gray1.   

Abstract

PURPOSE: Task Group 204 introduced effective diameter (ED) as the patient size metric used to correlate size-specific-dose-estimates. However, this size metric fails to account for patient attenuation properties and has been suggested to be replaced by an attenuation-based size metric, water equivalent diameter (DW). The purpose of this study is to investigate different size metrics, effective diameter, and water equivalent diameter, in combination with regional descriptions of scanner output to establish the most appropriate size metric to be used as a predictor for organ dose in tube current modulated CT exams.
METHODS: 101 thoracic and 82 abdomen/pelvis scans from clinically indicated CT exams were collected retrospectively from a multidetector row CT (Sensation 64, Siemens Healthcare) with Institutional Review Board approval to generate voxelized patient models. Fully irradiated organs (lung and breasts in thoracic scans and liver, kidneys, and spleen in abdominal scans) were segmented and used as tally regions in Monte Carlo simulations for reporting organ dose. Along with image data, raw projection data were collected to obtain tube current information for simulating tube current modulation scans using Monte Carlo methods. Additionally, previously described patient size metrics [ED, DW, and approximated water equivalent diameter (DWa)] were calculated for each patient and reported in three different ways: a single value averaged over the entire scan, a single value averaged over the region of interest, and a single value from a location in the middle of the scan volume. Organ doses were normalized by an appropriate mAs weighted CTDIvol to reflect regional variation of tube current. Linear regression analysis was used to evaluate the correlations between normalized organ doses and each size metric.
RESULTS: For the abdominal organs, the correlations between normalized organ dose and size metric were overall slightly higher for all three differently (global, regional, and middle slice) reported DW and DWa than they were for ED, but the differences were not statistically significant. However, for lung dose, computed correlations using water equivalent diameter calculated in the middle of the image data (DW,middle) and averaged over the low attenuating region of lung (DW,regional) were statistically significantly higher than correlations of normalized lung dose with ED.
CONCLUSIONS: To conclude, effective diameter and water equivalent diameter are very similar in abdominal regions; however, their difference becomes noticeable in lungs. Water equivalent diameter, specifically reported as a regional average and middle of scan volume, was shown to be better predictors of lung dose. Therefore, an attenuation-based size metric (water equivalent diameter) is recommended because it is more robust across different anatomic regions. Additionally, it was observed that the regional size metric reported as a single value averaged over a region of interest and the size metric calculated from a single slice/image chosen from the middle of the scan volume are highly correlated for these specific patient models and scan types.

Entities:  

Mesh:

Year:  2015        PMID: 25652508      PMCID: PMC6961670          DOI: 10.1118/1.4906132

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  18 in total

1.  A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models.

Authors:  G Jarry; J J DeMarco; U Beifuss; C H Cagnon; M F McNitt-Gray
Journal:  Phys Med Biol       Date:  2003-08-21       Impact factor: 3.609

2.  A comparison of methods to estimate organ doses in CT when utilizing approximations to the tube current modulation function.

Authors:  Maryam Khatonabadi; Di Zhang; Kelsey Mathieu; Hyun J Kim; Peiyun Lu; Dianna Cody; John J Demarco; Chris H Cagnon; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

3.  A CT-based Monte Carlo simulation tool for dosimetry planning and analysis.

Authors:  J J DeMarco; T D Solberg; J B Smathers
Journal:  Med Phys       Date:  1998-01       Impact factor: 4.071

4.  Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part II. Implementation on abdomen and thorax phantoms using cross sectional CT images and scanned projection radiograph images.

Authors:  Jia Wang; Jodie A Christner; Xinhui Duan; Shuai Leng; Lifeng Yu; Cynthia H McCollough
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

5.  Comparison of different body size parameters for individual dose adaptation in body CT of adults.

Authors:  Jan Menke
Journal:  Radiology       Date:  2005-08       Impact factor: 11.105

6.  An approach for the estimation of effective radiation dose at CT in pediatric patients.

Authors:  W Huda; J V Atherton; D E Ware; W A Cumming
Journal:  Radiology       Date:  1997-05       Impact factor: 11.105

7.  Comparison of topogram-based body size indices for CT dose consideration and scan protocol optimization.

Authors:  Baojun Li; Richard H Behrman; Alexander M Norbash
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

8.  The influence of patient centering on CT dose and image noise.

Authors:  Thomas Toth; Zhanyu Ge; Michael P Daly
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

9.  Radiation dose to the fetus for pregnant patients undergoing multidetector CT imaging: Monte Carlo simulations estimating fetal dose for a range of gestational age and patient size.

Authors:  Erin Angel; Clinton V Wellnitz; Mitchell M Goodsitt; Nazanin Yaghmai; John J DeMarco; Christopher H Cagnon; James W Sayre; Dianna D Cody; Donna M Stevens; Andrew N Primak; Cynthia H McCollough; Michael F McNitt-Gray
Journal:  Radiology       Date:  2008-10       Impact factor: 11.105

10.  Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part I. Development and validation of methods using the CT image.

Authors:  Jia Wang; Xinhui Duan; Jodie A Christner; Shuai Leng; Lifeng Yu; Cynthia H McCollough
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

View more
  11 in total

1.  Estimating patient dose from CT exams that use automatic exposure control: Development and validation of methods to accurately estimate tube current values.

Authors:  Kyle McMillan; Maryam Bostani; Christopher H Cagnon; Lifeng Yu; Shuai Leng; Cynthia H McCollough; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2017-06-30       Impact factor: 4.071

2.  Patient-Specific Organ and Effective Dose Estimates in Adult Oncologic CT.

Authors:  Yiming Gao; Usman Mahmood; Tianyu Liu; Brian Quinn; Marc J Gollub; X George Xu; Lawrence T Dauer
Journal:  AJR Am J Roentgenol       Date:  2019-08-15       Impact factor: 3.959

3.  Evaluation of CTPA interpreted as limited in pregnant patients suspected for pulmonary embolism.

Authors:  S L Cohen; J Wang; M Mankerian; C Feizullayeva; J A McCandlish; D Barnaby; P Sanelli; T McGinn
Journal:  Emerg Radiol       Date:  2019-12-07

4.  Physical validation of a Monte Carlo-based, phantom-derived approach to computed tomography organ dosimetry under tube current modulation.

Authors:  Elliott J Stepusin; Daniel J Long; Kayla R Ficarrotta; David E Hintenlang; Wesley E Bolch
Journal:  Med Phys       Date:  2017-09-22       Impact factor: 4.071

5.  Estimating organ doses from tube current modulated CT examinations using a generalized linear model.

Authors:  Maryam Bostani; Kyle McMillan; Peiyun Lu; Grace Hyun J Kim; Dianna Cody; Gary Arbique; S Bruce Greenberg; John J DeMarco; Chris H Cagnon; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2017-04       Impact factor: 4.071

6.  Comparison of methods to estimate water-equivalent diameter for calculation of patient dose.

Authors:  Andrew Daudelin; David Medich; Syed Yasir Andrabi; Chris Martel
Journal:  J Appl Clin Med Phys       Date:  2018-07-07       Impact factor: 2.102

7.  Organ doses evaluation for chest computed tomography procedures with TL dosimeters: Comparison with Monte Carlo simulations.

Authors:  Louise Giansante; Juliana C Martins; Denise Y Nersissian; Karen C Kiers; Fernando U Kay; Marcio V Y Sawamura; Choonsik Lee; Eloisa M M S Gebrim; Paulo R Costa
Journal:  J Appl Clin Med Phys       Date:  2018-12-03       Impact factor: 2.102

8.  Comparison of organ-specific-radiation dose levels between 70 kVp perfusion CT and standard tri-phasic liver CT in patients with hepatocellular carcinoma using a Monte-Carlo-Simulation-based analysis platform.

Authors:  J Gawlitza; H Haubenreisser; M Meyer; C Hagelstein; S Sudarski; S O Schoenberg; T Henzler
Journal:  Eur J Radiol Open       Date:  2016-05-07

9.  Automatic calculation of patient size metrics in computed tomography: What level of computational accuracy do we need?

Authors:  Sandra Sarmento; Bruno Mendes; Margarida Gouvêa
Journal:  J Appl Clin Med Phys       Date:  2017-12-19       Impact factor: 2.102

10.  Automated Calculation of Water-equivalent Diameter (DW) Based on AAPM Task Group 220.

Authors:  Choirul Anam; Freddy Haryanto; Rena Widita; Idam Arif; Geoff Dougherty
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.