Literature DB >> 25628271

Multiscale analyses of the bone-implant interface.

J Y Cha1, M D Pereira2, A A Smith2, K S Houschyar2, X Yin3, S Mouraret2, J B Brunski2, J A Helms4.   

Abstract

Implants placed with high insertion torque (IT) typically exhibit primary stability, which enables early loading. Whether high IT has a negative impact on peri-implant bone health, however, remains to be determined. The purpose of this study was to ascertain how peri-implant bone responds to strains and stresses created when implants are placed with low and high IT. Titanium micro-implants were inserted into murine femurs with low and high IT using torque values that were scaled to approximate those used to place clinically sized implants. Torque created in peri-implant tissues a distribution and magnitude of strains, which were calculated through finite element modeling. Stiffness tests quantified primary and secondary implant stability. At multiple time points, molecular, cellular, and histomorphometric analyses were performed to quantitatively determine the effect of high and low strains on apoptosis, mineralization, resorption, and collagen matrix deposition in peri-implant bone. Preparation of an osteotomy results in a narrow zone of dead and dying osteocytes in peri-implant bone that is not significantly enlarged in response to implants placed with low IT. Placing implants with high IT more than doubles this zone of dead and dying osteocytes. As a result, peri-implant bone develops micro-fractures, bone resorption is increased, and bone formation is decreased. Using high IT to place an implant creates high interfacial stress and strain that are associated with damage to peri-implant bone and therefore should be avoided to best preserve the viability of this tissue. © International & American Associations for Dental Research 2015.

Entities:  

Keywords:  biological process; dental implantation; finite element analysis; orthodontic anchorage techniques; osseointegration; prosthesis implantation

Mesh:

Substances:

Year:  2015        PMID: 25628271      PMCID: PMC4814020          DOI: 10.1177/0022034514566029

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  16 in total

1.  The use of small titanium screws for orthodontic anchorage.

Authors:  T Deguchi; T Takano-Yamamoto; R Kanomi; J K Hartsfield; W E Roberts; L P Garetto
Journal:  J Dent Res       Date:  2003-05       Impact factor: 6.116

2.  Immediate functional loading of Brånemark System implants with enhanced initial stability: a prospective 1- to 2-year clinical and radiographic study.

Authors:  Roberto Calandriello; Massimiliano Tomatis; Bo Rangert
Journal:  Clin Implant Dent Relat Res       Date:  2003       Impact factor: 3.932

3.  Histological, histomorphometrical, and radiological evaluation of an experimental implant design with a high insertion torque.

Authors:  Joke Duyck; Livía Corpas; Stephanie Vermeiren; Toru Ogawa; Marc Quirynen; Katleen Vandamme; Reinhilde Jacobs; Ignace Naert
Journal:  Clin Oral Implants Res       Date:  2010-04-30       Impact factor: 5.977

4.  Miniscrew stability evaluated with computerized tomography scanning.

Authors:  Jung-Yul Cha; Jae-Kyoung Kil; Tae-Min Yoon; Chung-Ju Hwang
Journal:  Am J Orthod Dentofacial Orthop       Date:  2010-01       Impact factor: 2.650

5.  High versus low implant insertion torque: a histologic, histomorphometric, and biomechanical study in the sheep mandible.

Authors:  Paolo Trisi; Marzio Todisco; Ugo Consolo; Domenico Travaglini
Journal:  Int J Oral Maxillofac Implants       Date:  2011 Jul-Aug       Impact factor: 2.804

6.  Clinical outcome and bone healing of implants placed with high insertion torque: 12-month results from a multicenter controlled cohort study.

Authors:  T Grandi; P Guazzi; R Samarani; G Grandi
Journal:  Int J Oral Maxillofac Surg       Date:  2012-11-16       Impact factor: 2.789

7.  The impact of bone compression on bone-to-implant contact of an osseointegrated implant: a canine study.

Authors:  Myron Nevins; Marc L Nevins; Peter Schupbach; Joseph Fiorellini; Zhao Lin; David M Kim
Journal:  Int J Periodontics Restorative Dent       Date:  2012-12       Impact factor: 1.840

Review 8.  Interventions for replacing missing teeth: different times for loading dental implants.

Authors:  Marco Esposito; Maria Gabriella Grusovin; Hassan Maghaireh; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2013-03-28

9.  Bone remodeling in response to in vivo fatigue microdamage.

Authors:  D B Burr; R B Martin; M B Schaffler; E L Radin
Journal:  J Biomech       Date:  1985       Impact factor: 2.712

10.  Wnt proteins promote bone regeneration.

Authors:  Steven Minear; Philipp Leucht; Jie Jiang; Bo Liu; Arial Zeng; Christophe Fuerer; Roel Nusse; Jill A Helms
Journal:  Sci Transl Med       Date:  2010-04-28       Impact factor: 17.956

View more
  26 in total

1.  Enhancing osseointegration of titanium implants through large-grit sandblasting combined with micro-arc oxidation surface modification.

Authors:  Wulin He; Xing Yin; Li Xie; Zeping Liu; Jingtao Li; Shujuan Zou; Jianwei Chen
Journal:  J Mater Sci Mater Med       Date:  2019-06-11       Impact factor: 3.896

2.  Contribution of the PDL to Osteotomy Repair and Implant Osseointegration.

Authors:  X Pei; L Wang; C Chen; X Yuan; Q Wan; J A Helms
Journal:  J Dent Res       Date:  2017-05-08       Impact factor: 6.116

Review 3.  Advanced computational workflow for the multi-scale modeling of the bone metabolic processes.

Authors:  Tien Tuan Dao
Journal:  Med Biol Eng Comput       Date:  2016-09-16       Impact factor: 2.602

4.  A Comparative Assessment of Implant Site Viability in Humans and Rats.

Authors:  C-H Chen; X Pei; U S Tulu; M Aghvami; C-T Chen; D Gaudillière; M Arioka; M Maghazeh Moghim; O Bahat; M Kolinski; T R Crosby; A Felderhoff; J B Brunski; J A Helms
Journal:  J Dent Res       Date:  2017-12-04       Impact factor: 6.116

5.  3D full-field strain in bone-implant and bone-tooth constructs and their morphological influential factors.

Authors:  Yuxiao Zhou; Chujie Gong; Mehran Hossaini-Zadeh; Jing Du
Journal:  J Mech Behav Biomed Mater       Date:  2020-05-19

6.  Rescuing failed oral implants via Wnt activation.

Authors:  Xing Yin; Jingtao Li; Tao Chen; Sylvain Mouraret; Girija Dhamdhere; John B Brunski; Shujuan Zou; Jill A Helms
Journal:  J Clin Periodontol       Date:  2016-02-12       Impact factor: 8.728

7.  Effect of guided bone regeneration on bone quality surrounding dental implants.

Authors:  Trenton B Johnson; Ben Siderits; Seth Nye; Yong-Hoon Jeong; Seung-Hee Han; In-Chul Rhyu; Jung-Suk Han; Toru Deguchi; F Michael Beck; Do-Gyoon Kim
Journal:  J Biomech       Date:  2018-08-22       Impact factor: 2.712

8.  Biophysical regulation of osteotomy healing: An animal study.

Authors:  Liao Wang; Maziar Aghvami; John Brunski; Jill Helms
Journal:  Clin Implant Dent Relat Res       Date:  2017-06-13       Impact factor: 3.932

9.  Biomechanics of Immediate Postextraction Implant Osseointegration.

Authors:  X Yuan; X Pei; Y Zhao; Z Li; C H Chen; U S Tulu; B Liu; L A Van Brunt; J B Brunski; J A Helms
Journal:  J Dent Res       Date:  2018-04-02       Impact factor: 6.116

10.  Effect of cyclic loading on the stability of screws placed in the locking plates used to bridge segmental bone defects.

Authors:  Remigiusz M Grzeskowiak; Laura R Freeman; David P Harper; David E Anderson; Pierre-Yves Mulon
Journal:  J Orthop Res       Date:  2020-09-09       Impact factor: 3.494

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.