Literature DB >> 23159169

Clinical outcome and bone healing of implants placed with high insertion torque: 12-month results from a multicenter controlled cohort study.

T Grandi1, P Guazzi, R Samarani, G Grandi.   

Abstract

This study evaluated the clinical outcome and the crestal bone resorption of implants placed with high insertion torque (up to 80 N cm). 102 patients were treated with 156 tapered implants. 42 implants (control group) presented insertion torque between 30 and 45 N cm (mean=37.4 SD 8.2). 114 implants (experimental group) were placed with insertion torque between 50 and 80 N cm (mean=74.8 SD 7.9). All implants were early loaded after 2 months. Peri-implant marginal bone levels were assessed immediately after surgery, and at 6- and 12-month follow up examinations. At the 12-month follow up all implants were clinically stable. After 12 months, patients in the experimental group lost an average of 0.41 mm (CI 95% 0.522; 0.263) of crestal bone compared with 0.45 mm (CI 95% 0.561; 0.286) for those in the control group. There were no significant differences between the two groups. No direct or inverse relationship was observed between the insertion torque values and crestal bone resorption. The results show that the use of high insertion torque (up to 80 N cm) did not prevent osseointegration and did not increase bone resorption around tapered implants early loaded up to 1 year after implant placement.
Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23159169     DOI: 10.1016/j.ijom.2012.10.013

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  4 in total

1.  Multiscale analyses of the bone-implant interface.

Authors:  J Y Cha; M D Pereira; A A Smith; K S Houschyar; X Yin; S Mouraret; J B Brunski; J A Helms
Journal:  J Dent Res       Date:  2015-01-27       Impact factor: 6.116

2.  Orthodontic mini-implant stability at different insertion depths : Sensitivity of three stability measurement methods.

Authors:  Manuel Nienkemper; Natascha Santel; Ralf Hönscheid; Dieter Drescher
Journal:  J Orofac Orthop       Date:  2016-06-07       Impact factor: 1.938

3.  Rescuing failed oral implants via Wnt activation.

Authors:  Xing Yin; Jingtao Li; Tao Chen; Sylvain Mouraret; Girija Dhamdhere; John B Brunski; Shujuan Zou; Jill A Helms
Journal:  J Clin Periodontol       Date:  2016-02-12       Impact factor: 8.728

4.  Twist removal of healed vs. nonhealed implants-a mechanical and histological study in mini pigs.

Authors:  Ricardo de Oliveira Silva; Fabrício Passador; Paulo Henrique Ferreira Caria
Journal:  Int J Implant Dent       Date:  2016-11-25
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.