Literature DB >> 12691646

Immediate functional loading of Brånemark System implants with enhanced initial stability: a prospective 1- to 2-year clinical and radiographic study.

Roberto Calandriello1, Massimiliano Tomatis, Bo Rangert.   

Abstract

BACKGROUND: The interest in the benefits of immediate loading of titanium implants has recently involved fixed prostheses for partially edentulous areas. The advantages of this approach well justify the need for extending the procedure to all regions of the mouth. Current available clinical literature on this subject is incomplete.
PURPOSE: The purpose of this study is to investigate the clinical outcome of the immediate loading of Brånemark System implants (Nobel Biocare AB, Gothenburg, Sweden) inserted with enhanced initial stability principally in posterior sites (78%).
MATERIALS AND METHODS: The present study was conducted in 26 consecutively treated patients. A total of 50 Brånemark System machined surface implants were placed supporting 30 fixed temporary partial dentures in light occlusion. All implants were followed up for a minimum of 1 year of function. Minimum requirements for immediate loading were proposed. Bone quality and quantity were classified according to Lekholm and Zarb's criteria. Stability of the marginal bone level, both mesial and distal, was measured on the basis of radiographic analysis. Implant survival rate was calculated according to Kaplan-Meier analysis. The peak insertion torque employed during fixture placement was between 40 and 72 Ncm, except in the case of one implant that was lost.
RESULTS: Overall survival rate was 98%. An unpaired t-test revealed bone remodeling conforming to biologic width establishment (p <.005).
CONCLUSIONS: Within the limit of this study, immediate loading appears to be a viable procedure in posterior sites and for a growing number of clinical indications. Enhanced implant stability and light occlusion seem to be security factors. In spite of unfavorable conditions such as the presence of quality 4 bone and a lack of splinting, all implants with enhanced primary stability survived.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12691646     DOI: 10.1111/j.1708-8208.2003.tb00011.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  8 in total

1.  [Microbiological study on the prognosis of immediate implant and periodontal disease].

Authors:  A Rabel; S G Köhler
Journal:  Mund Kiefer Gesichtschir       Date:  2006-01

2.  Randomised study for the 1-year crestal bone maintenance around modified diameter implants with different loading protocols: a radiographic evaluation.

Authors:  Matteo Danza; Pietro Tortora; Alessandro Quaranta; Vittoria Perrotti; Iole Vozza; Adriano Piattelli
Journal:  Clin Oral Investig       Date:  2009-07-15       Impact factor: 3.573

3.  Multiscale analyses of the bone-implant interface.

Authors:  J Y Cha; M D Pereira; A A Smith; K S Houschyar; X Yin; S Mouraret; J B Brunski; J A Helms
Journal:  J Dent Res       Date:  2015-01-27       Impact factor: 6.116

4.  Clinical indications, advantages and limits of the expansion-condensing osteotomes technique for the creation of implant bed.

Authors:  G DE Vico; M Bonino; D Spinelli; A Pozzi; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2009-12-10

5.  Effects of Immediate and Delayed Loading on the Outcomes of All-on-4 Treatment: A Prospective Study.

Authors:  Hossein Najafi; Hakimeh Siadat; Solmaz Akbari; Amirreza Rokn
Journal:  J Dent (Tehran)       Date:  2016-11

6.  Biomechanical Effects of a New Macrogeometry Design of Dental Implants: An In Vitro Experimental Analysis.

Authors:  Sergio Alexandre Gehrke; Leticia Pérez-Díaz; Patricia Mazón; Piedad N De Aza
Journal:  J Funct Biomater       Date:  2019-10-25

7.  Effects of the Healing Chambers in Implant Macrogeometry Design in a Low-Density Bone Using Conventional and Undersized Drilling.

Authors:  Sergio A Gehrke; Antônio Scarano; José H C de Lima; Marco A Bianchini; Berenice A Dedavid; Piedad N De Aza
Journal:  J Int Soc Prev Community Dent       Date:  2021-07-30

8.  Study to assess the relationship between insertion torque value and implant stability quotient and its influence on timing of functional implant loading.

Authors:  Hasan Sarfaraz; Shefali Johri; P Sucheta; Sripathi Rao
Journal:  J Indian Prosthodont Soc       Date:  2018 Apr-Jun
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.