Literature DB >> 25575100

Characterization of 3D joint space morphology using an electrostatic model (with application to osteoarthritis).

Qian Cao1, Gaurav Thawait, Grace J Gang, Wojciech Zbijewski, Thomas Reigel, Tyler Brown, Brian Corner, Shadpour Demehri, Jeffrey H Siewerdsen.   

Abstract

Joint space morphology can be indicative of the risk, presence, progression, and/or treatment response of disease or trauma. We describe a novel methodology of characterizing joint space morphology in high-resolution 3D images (e.g. cone-beam CT (CBCT)) using a model based on elementary electrostatics that overcomes a variety of basic limitations of existing 2D and 3D methods. The method models each surface of a joint as a conductor at fixed electrostatic potential and characterizes the intra-articular space in terms of the electric field lines resulting from the solution of Gauss' Law and the Laplace equation. As a test case, the method was applied to discrimination of healthy and osteoarthritic subjects (N = 39) in 3D images of the knee acquired on an extremity CBCT system. The method demonstrated improved diagnostic performance (area under the receiver operating characteristic curve, AUC > 0.98) compared to simpler methods of quantitative measurement and qualitative image-based assessment by three expert musculoskeletal radiologists (AUC = 0.87, p-value = 0.007). The method is applicable to simple (e.g. the knee or elbow) or multi-axial joints (e.g. the wrist or ankle) and may provide a useful means of quantitatively assessing a variety of joint pathologies.

Entities:  

Mesh:

Year:  2015        PMID: 25575100      PMCID: PMC4539937          DOI: 10.1088/0031-9155/60/3/947

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

1.  An Eulerian PDE approach for computing tissue thickness.

Authors:  Anthony J Yezzi; Jerry L Prince
Journal:  IEEE Trans Med Imaging       Date:  2003-10       Impact factor: 10.048

2.  Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging.

Authors:  P Prakash; W Zbijewski; G J Gang; Y Ding; J W Stayman; J Yorkston; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

Review 3.  Measurement of joint space width and erosion size.

Authors:  John T Sharp; Desiree van der Heijde; Jane Angwin; Jeff Duryea; Heins J Bernelot Moens; Johannes W G Jacobs; Jean-Francis Maillefert; C Vibeke Strand
Journal:  J Rheumatol       Date:  2005-12       Impact factor: 4.666

4.  Osteoarthritis of the knee: multicompartmental or compartmental disease?

Authors:  Martin van der Esch; Dirk L Knol; Ilse C Schaffers; Dick J Reiding; Dirkjan van Schaardenburg; Jesper Knoop; Leo D Roorda; Willem F Lems; Joost Dekker
Journal:  Rheumatology (Oxford)       Date:  2013-11-29       Impact factor: 7.580

5.  Maximum likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data.

Authors:  C E Metz; B A Herman; J H Shen
Journal:  Stat Med       Date:  1998-05-15       Impact factor: 2.373

6.  Automatic boundary detection of the left ventricle from cineangiograms.

Authors:  C K Chow; T Kaneko
Journal:  Comput Biomed Res       Date:  1972-08

7.  A dedicated cone-beam CT system for musculoskeletal extremities imaging: design, optimization, and initial performance characterization.

Authors:  W Zbijewski; P De Jean; P Prakash; Y Ding; J W Stayman; N Packard; R Senn; D Yang; J Yorkston; A Machado; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

8.  Robust statistical shape models for MRI bone segmentation in presence of small field of view.

Authors:  Jérôme Schmid; Jinman Kim; Nadia Magnenat-Thalmann
Journal:  Med Image Anal       Date:  2010-09-24       Impact factor: 8.545

9.  Peripheral Quantitative CT (pQCT) Using a Dedicated Extremity Cone-Beam CT Scanner.

Authors:  A A Muhit; S Arora; M Ogawa; Y Ding; W Zbijewski; J W Stayman; G Thawait; N Packard; R Senn; D Yang; J Yorkston; C O Bingham; K Means; J A Carrino; J H Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-29

10.  Prevalence of doctor-diagnosed arthritis and arthritis-attributable activity limitation--United States, 2010-2012.

Authors: 
Journal:  MMWR Morb Mortal Wkly Rep       Date:  2013-11-08       Impact factor: 17.586

View more
  10 in total

1.  Marker-free motion correction in weight-bearing cone-beam CT of the knee joint.

Authors:  M Berger; K Müller; A Aichert; M Unberath; J Thies; J-H Choi; R Fahrig; A Maier
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

2.  Modeling and evaluation of a high-resolution CMOS detector for cone-beam CT of the extremities.

Authors:  Qian Cao; Alejandro Sisniega; Michael Brehler; J Webster Stayman; John Yorkston; Jeffrey H Siewerdsen; Wojciech Zbijewski
Journal:  Med Phys       Date:  2017-11-27       Impact factor: 4.071

3.  Motion compensation in extremity cone-beam CT using a penalized image sharpness criterion.

Authors:  A Sisniega; J W Stayman; J Yorkston; J H Siewerdsen; W Zbijewski
Journal:  Phys Med Biol       Date:  2017-03-22       Impact factor: 3.609

4.  Extremity cone-beam CT for evaluation of medial tibiofemoral osteoarthritis: Initial experience in imaging of the weight-bearing and non-weight-bearing knee.

Authors:  Gaurav K Thawait; Shadpour Demehri; Abdullah AlMuhit; Wojciech Zbijweski; John Yorkston; Filippo Del Grande; Bashir Zikria; John A Carrino; Jeffrey H Siewerdsen
Journal:  Eur J Radiol       Date:  2015-09-12       Impact factor: 3.528

5.  Articular surface segmentation using active shape models for intraoperative implant assessment.

Authors:  Joseph Görres; Michael Brehler; Jochen Franke; Sven Y Vetter; Paul A Grützner; Hans-Peter Meinzer; Ivo Wolf
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-04-19       Impact factor: 2.924

6.  Intra-operative assessment of fractured articular surfaces in cone beam CT image data.

Authors:  Michael Brehler; Joseph Görres; Sven Y Vetter; Jochen Franke; Paul A Grützner; Hans-Peter Meinzer; Ivo Wolf
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-10-08       Impact factor: 2.924

7.  Three-dimensional mapping of the joint space for the diagnosis of knee osteoarthritis based on high resolution computed tomography: Comparison with radiographic, outerbridge, and meniscal classifications.

Authors:  Houda Mezlini-Gharsallah; Rabaa Youssef; Stéphanie Uk; Jean D Laredo; Christine Chappard
Journal:  J Orthop Res       Date:  2018-04-27       Impact factor: 3.494

8.  Determining diagnosis of scaphoid healing: Comparison of cone beam CT and X-ray after six weeks of immobilization.

Authors:  Lucia Calisto Farracho; Berenice Moutinot; Angeliki Neroladaki; Marion Hamard; Karel Gorican; Pierre Alexandre Poletti; Jean Yves Beaulieu; Cindy Bouvet; Sana Boudabbous
Journal:  Eur J Radiol Open       Date:  2020-09-02

9.  Comparison of Different Approaches for Measuring Tibial Cartilage Thickness.

Authors:  Jennifer Maier; Marianne Black; Serena Bonaretti; Bastian Bier; Bjoern Eskofier; Jang-Hwan Choi; Marc Levenston; Garry Gold; Rebecca Fahrig; Andreas Maier
Journal:  J Integr Bioinform       Date:  2017-07-28

10.  Landmark-free morphometric analysis of knee osteoarthritis using joint statistical models of bone shape and articular space variability.

Authors:  Nicolas Charon; Asef Islam; Wojciech Zbijewski
Journal:  J Med Imaging (Bellingham)       Date:  2021-07-05
  10 in total