Literature DB >> 25574431

Adaptive optics optical coherence tomography at 1 MHz.

Omer P Kocaoglu1, Timothy L Turner1, Zhuolin Liu1, Donald T Miller1.   

Abstract

Image acquisition speed of optical coherence tomography (OCT) remains a fundamental barrier that limits its scientific and clinical utility. Here we demonstrate a novel multi-camera adaptive optics (AO-)OCT system for ophthalmologic use that operates at 1 million A-lines/s at a wavelength of 790 nm with 5.3 μm axial resolution in retinal tissue. Central to the spectral-domain design is a novel detection channel based on four high-speed spectrometers that receive light sequentially from a 1 × 4 optical switch assembly. Absence of moving parts enables ultra-fast (50ns) and precise switching with low insertion loss (-0.18 dB per channel). This manner of control makes use of all available light in the detection channel and avoids camera dead-time, both critical for imaging at high speeds. Additional benefit in signal-to-noise accrues from the larger numerical aperture afforded by the use of AO and yields retinal images of comparable dynamic range to that of clinical OCT. We validated system performance by a series of experiments that included imaging in both model and human eyes. We demonstrated the performance of our MHz AO-OCT system to capture detailed images of individual retinal nerve fiber bundles and cone photoreceptors. This is the fastest ophthalmic OCT system we know of in the 700 to 915 nm spectral band.

Entities:  

Keywords:  (110.1080) Active or adaptive optics; (120.3890) Medical optics instrumentation; (170.0110) Imaging systems; (170.4470) Ophthalmology; (170.4500) Optical coherence tomography; (330.5310) Vision - photoreceptors

Year:  2014        PMID: 25574431      PMCID: PMC4285598          DOI: 10.1364/BOE.5.004186

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  19 in total

1.  Large-field-of-view, modular, stabilized, adaptive-optics-based scanning laser ophthalmoscope.

Authors:  Stephen A Burns; Remy Tumbar; Ann E Elsner; Daniel Ferguson; Daniel X Hammer
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-05       Impact factor: 2.129

2.  Performance of fourier domain vs. time domain optical coherence tomography.

Authors:  R Leitgeb; C Hitzenberger; Adolf Fercher
Journal:  Opt Express       Date:  2003-04-21       Impact factor: 3.894

3.  Ultrahigh-resolution optical coherence tomography with monochromatic and chromatic aberration correction.

Authors:  Robert J Zawadzki; Barry Cense; Yan Zhang; Stacey S Choi; Donald T Miller; John S Werner
Journal:  Opt Express       Date:  2008-05-26       Impact factor: 3.894

4.  Multi-MHz retinal OCT.

Authors:  Thomas Klein; Wolfgang Wieser; Lukas Reznicek; Aljoscha Neubauer; Anselm Kampik; Robert Huber
Journal:  Biomed Opt Express       Date:  2013-08-30       Impact factor: 3.732

5.  Optical coherence tomography.

Authors:  D Huang; E A Swanson; C P Lin; J S Schuman; W G Stinson; W Chang; M R Hee; T Flotte; K Gregory; C A Puliafito
Journal:  Science       Date:  1991-11-22       Impact factor: 47.728

6.  Autocalibration of spectral-domain optical coherence tomography spectrometers for in vivo quantitative retinal nerve fiber layer birefringence determination.

Authors:  Mircea Mujat; B Hyle Park; Barry Cense; Teresa C Chen; Johannes F de Boer
Journal:  J Biomed Opt       Date:  2007 Jul-Aug       Impact factor: 3.170

7.  Adaptive optics optical coherence tomography with dynamic retinal tracking.

Authors:  Omer P Kocaoglu; R Daniel Ferguson; Ravi S Jonnal; Zhuolin Liu; Qiang Wang; Daniel X Hammer; Donald T Miller
Journal:  Biomed Opt Express       Date:  2014-06-17       Impact factor: 3.732

8.  In-the-plane design of an off-axis ophthalmic adaptive optics system using toroidal mirrors.

Authors:  Zhuolin Liu; Omer P Kocaoglu; Donald T Miller
Journal:  Biomed Opt Express       Date:  2013-11-26       Impact factor: 3.732

9.  Retinal imaging with polarization-sensitive optical coherence tomography and adaptive optics.

Authors:  Barry Cense; Weihua Gao; Jeffrey M Brown; Steven M Jones; Ravi S Jonnal; Mircea Mujat; B Hyle Park; Johannes F de Boer; Donald T Miller
Journal:  Opt Express       Date:  2009-11-23       Impact factor: 3.894

10.  Retinal, anterior segment and full eye imaging using ultrahigh speed swept source OCT with vertical-cavity surface emitting lasers.

Authors:  Ireneusz Grulkowski; Jonathan J Liu; Benjamin Potsaid; Vijaysekhar Jayaraman; Chen D Lu; James Jiang; Alex E Cable; Jay S Duker; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2012-10-03       Impact factor: 3.732

View more
  49 in total

1.  Imaging of retinal vasculature using adaptive optics SLO/OCT.

Authors:  Franz Felberer; Matthias Rechenmacher; Richard Haindl; Bernhard Baumann; Christoph K Hitzenberger; Michael Pircher
Journal:  Biomed Opt Express       Date:  2015-03-23       Impact factor: 3.732

Review 2.  Cellular-Scale Imaging of Transparent Retinal Structures and Processes Using Adaptive Optics Optical Coherence Tomography.

Authors:  Donald T Miller; Kazuhiro Kurokawa
Journal:  Annu Rev Vis Sci       Date:  2020-07-01       Impact factor: 6.422

Review 3.  In vivo imaging methods to assess glaucomatous optic neuropathy.

Authors:  Brad Fortune
Journal:  Exp Eye Res       Date:  2015-06-03       Impact factor: 3.467

4.  Ultra-widefield retinal MHz-OCT imaging with up to 100 degrees viewing angle.

Authors:  Jan Philip Kolb; Thomas Klein; Corinna L Kufner; Wolfgang Wieser; Aljoscha S Neubauer; Robert Huber
Journal:  Biomed Opt Express       Date:  2015-04-02       Impact factor: 3.732

5.  Line-field parallel swept source MHz OCT for structural and functional retinal imaging.

Authors:  Daniel J Fechtig; Branislav Grajciar; Tilman Schmoll; Cedric Blatter; Rene M Werkmeister; Wolfgang Drexler; Rainer A Leitgeb
Journal:  Biomed Opt Express       Date:  2015-02-04       Impact factor: 3.732

6.  In vivo imaging of human photoreceptor mosaic with wavefront sensorless adaptive optics optical coherence tomography.

Authors:  Kevin S K Wong; Yifan Jian; Michelle Cua; Stefano Bonora; Robert J Zawadzki; Marinko V Sarunic
Journal:  Biomed Opt Express       Date:  2015-01-16       Impact factor: 3.732

7.  In vivo measurement of organelle motility in human retinal pigment epithelial cells.

Authors:  Zhuolin Liu; Kazuhiro Kurokawa; Daniel X Hammer; Donald T Miller
Journal:  Biomed Opt Express       Date:  2019-07-19       Impact factor: 3.732

Review 8.  High-speed OCT light sources and systems [Invited].

Authors:  Thomas Klein; Robert Huber
Journal:  Biomed Opt Express       Date:  2017-01-13       Impact factor: 3.732

9.  Adaptive optics optical coherence tomography angiography for morphometric analysis of choriocapillaris [Invited].

Authors:  Kazuhiro Kurokawa; Zhuolin Liu; Donald T Miller
Journal:  Biomed Opt Express       Date:  2017-02-24       Impact factor: 3.732

Review 10.  Review of adaptive optics OCT (AO-OCT): principles and applications for retinal imaging [Invited].

Authors:  Michael Pircher; Robert J Zawadzki
Journal:  Biomed Opt Express       Date:  2017-04-19       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.