Literature DB >> 26137363

Ultra-widefield retinal MHz-OCT imaging with up to 100 degrees viewing angle.

Jan Philip Kolb1, Thomas Klein2, Corinna L Kufner3, Wolfgang Wieser2, Aljoscha S Neubauer4, Robert Huber1.   

Abstract

We evaluate strategies to maximize the field of view (FOV) of in vivo retinal OCT imaging of human eyes. Three imaging modes are tested: Single volume imaging with 85° FOV as well as with 100° and stitching of five 60° images to a 100° mosaic (measured from the nodal point). We employ a MHz-OCT system based on a 1060nm Fourier domain mode locked (FDML) laser with a depth scan rate of 1.68MHz. The high speed is essential for dense isotropic sampling of the large areas. Challenges caused by the wide FOV are discussed and solutions to most issues are presented. Detailed information on the design and characterization of our sample arm optics is given. We investigate the origin of an angle dependent signal fall-off which we observe towards larger imaging angles. It is present in our 85° and 100° single volume images, but not in the mosaic. Our results suggest that 100° FOV OCT is possible with current swept source OCT technology.

Entities:  

Keywords:  (120.3890) Medical optics instrumentation; (140.3510) Lasers, fiber; (170.3880) Medical and biological imaging; (170.4460) Ophthalmic optics and devices; (170.4500) Optical coherence tomography

Year:  2015        PMID: 26137363      PMCID: PMC4467705          DOI: 10.1364/BOE.6.001534

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  51 in total

1.  Multi-megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second.

Authors:  Wolfgang Wieser; Benjamin R Biedermann; Thomas Klein; Christoph M Eigenwillig; Robert Huber
Journal:  Opt Express       Date:  2010-07-05       Impact factor: 3.894

2.  Buffered Fourier domain mode locking: Unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s.

Authors:  Robert Huber; Desmond C Adler; James G Fujimoto
Journal:  Opt Lett       Date:  2006-10-15       Impact factor: 3.776

Review 3.  Microsaccades: a neurophysiological analysis.

Authors:  Susana Martinez-Conde; Stephen L Macknik; Xoana G Troncoso; David H Hubel
Journal:  Trends Neurosci       Date:  2009-08-26       Impact factor: 13.837

4.  Megahertz OCT for ultrawide-field retinal imaging with a 1050 nm Fourier domain mode-locked laser.

Authors:  Thomas Klein; Wolfgang Wieser; Christoph M Eigenwillig; Benjamin R Biedermann; Robert Huber
Journal:  Opt Express       Date:  2011-02-14       Impact factor: 3.894

5.  Comprehensive in vivo micro-vascular imaging of the human eye by dual-beam-scan Doppler optical coherence angiography.

Authors:  Shuichi Makita; Franck Jaillon; Masahiro Yamanari; Masahiro Miura; Yoshiaki Yasuno
Journal:  Opt Express       Date:  2011-01-17       Impact factor: 3.894

6.  Adaptive optics optical coherence tomography at 1 MHz.

Authors:  Omer P Kocaoglu; Timothy L Turner; Zhuolin Liu; Donald T Miller
Journal:  Biomed Opt Express       Date:  2014-11-06       Impact factor: 3.732

7.  Three-beam spectral-domain optical coherence tomography for retinal imaging.

Authors:  Nobuhito Suehira; Sotaro Ooto; Masanori Hangai; Kazuhiro Matsumoto; Nobuhiro Tomatsu; Takashi Yuasa; Kazuro Yamada; Nagahisa Yoshimura
Journal:  J Biomed Opt       Date:  2012-10       Impact factor: 3.170

8.  Real-time eye motion compensation for OCT imaging with tracking SLO.

Authors:  Kari V Vienola; Boy Braaf; Christy K Sheehy; Qiang Yang; Pavan Tiruveedhula; David W Arathorn; Johannes F de Boer; Austin Roorda
Journal:  Biomed Opt Express       Date:  2012-10-24       Impact factor: 3.732

9.  Automatic montage of SD-OCT data sets.

Authors:  Ying Li; Giovanni Gregori; Byron L Lam; Philip J Rosenfeld
Journal:  Opt Express       Date:  2011-12-19       Impact factor: 3.894

10.  Choriocapillaris and choroidal microvasculature imaging with ultrahigh speed OCT angiography.

Authors:  WooJhon Choi; Kathrin J Mohler; Benjamin Potsaid; Chen D Lu; Jonathan J Liu; Vijaysekhar Jayaraman; Alex E Cable; Jay S Duker; Robert Huber; James G Fujimoto
Journal:  PLoS One       Date:  2013-12-11       Impact factor: 3.240

View more
  47 in total

1.  Combined 60° Wide-Field Choroidal Thickness Maps and High-Definition En Face Vasculature Visualization Using Swept-Source Megahertz OCT at 1050 nm.

Authors:  Kathrin J Mohler; Wolfgang Draxinger; Thomas Klein; Jan Philip Kolb; Wolfgang Wieser; Christos Haritoglou; Anselm Kampik; James G Fujimoto; Aljoscha S Neubauer; Robert Huber; Armin Wolf
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-10       Impact factor: 4.799

Review 2.  Advances of optical coherence tomography in myopia and pathologic myopia.

Authors:  D S C Ng; C Y L Cheung; F O Luk; S Mohamed; M E Brelen; J C S Yam; C W Tsang; T Y Y Lai
Journal:  Eye (Lond)       Date:  2016-04-08       Impact factor: 3.775

3.  Wide-field whole eye OCT system with demonstration of quantitative retinal curvature estimation.

Authors:  Ryan P McNabb; James Polans; Brenton Keller; Moseph Jackson-Atogi; Charlene L James; Robin R Vann; Joseph A Izatt; Anthony N Kuo
Journal:  Biomed Opt Express       Date:  2018-12-21       Impact factor: 3.732

4.  Maximum value projection produces better en face OCT angiograms than mean value projection.

Authors:  Tristan T Hormel; Jie Wang; Steven T Bailey; Thomas S Hwang; David Huang; Yali Jia
Journal:  Biomed Opt Express       Date:  2018-11-26       Impact factor: 3.732

5.  Wavelength agile multi-photon microscopy with a fiber amplified diode laser.

Authors:  Matthias Eibl; Daniel Weng; Hubertus Hakert; Jan Philip Kolb; Tom Pfeiffer; Jennifer E Hundt; Robert Huber; Sebastian Karpf
Journal:  Biomed Opt Express       Date:  2018-11-15       Impact factor: 3.732

6.  Efficient and high accuracy 3-D OCT angiography motion correction in pathology.

Authors:  Stefan B Ploner; Martin F Kraus; Eric M Moult; Lennart Husvogt; Julia Schottenhamml; A Yasin Alibhai; Nadia K Waheed; Jay S Duker; James G Fujimoto; Andreas K Maier
Journal:  Biomed Opt Express       Date:  2020-12-08       Impact factor: 3.732

7.  Multi-beam OCT imaging based on an integrated, free-space interferometer.

Authors:  Yongjoo Kim; Norman Lippok; Benjamin J Vakoc
Journal:  Biomed Opt Express       Date:  2020-12-08       Impact factor: 3.732

8.  Flexible A-scan rate MHz-OCT: efficient computational downscaling by coherent averaging.

Authors:  Tom Pfeiffer; Madita Göb; Wolfgang Draxinger; Sebastian Karpf; Jan Philip Kolb; Robert Huber
Journal:  Biomed Opt Express       Date:  2020-10-29       Impact factor: 3.732

9.  Twenty-five years of optical coherence tomography: the paradigm shift in sensitivity and speed provided by Fourier domain OCT [Invited].

Authors:  Johannes F de Boer; Rainer Leitgeb; Maciej Wojtkowski
Journal:  Biomed Opt Express       Date:  2017-06-15       Impact factor: 3.732

10.  Simultaneous multimodal ophthalmic imaging using swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography.

Authors:  Joseph D Malone; Mohamed T El-Haddad; Ivan Bozic; Logan A Tye; Lucas Majeau; Nicolas Godbout; Andrew M Rollins; Caroline Boudoux; Karen M Joos; Shriji N Patel; Yuankai K Tao
Journal:  Biomed Opt Express       Date:  2016-12-12       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.