Literature DB >> 17867794

Autocalibration of spectral-domain optical coherence tomography spectrometers for in vivo quantitative retinal nerve fiber layer birefringence determination.

Mircea Mujat1, B Hyle Park, Barry Cense, Teresa C Chen, Johannes F de Boer.   

Abstract

Accurate wavelength assignment of each spectral element for spectral-domain optical coherence tomography (SD-OCT) and optical frequency domain imaging (OFDI) is required for proper construction of biological tissue cross-sectional images. This becomes more critical for functional extensions of these techniques, especially in polarization-sensitive optical coherence tomography (PS-OCT), where incorrect wavelength assignment between the two orthogonal polarization channels leads to polarization artifacts. We present an autocalibration method for wavelength assignment that does not require separate calibration measurements and that can be applied directly on actual data. Removal of the birefringence artifact is demonstrated in a PS-OCT system with picometer accuracy in the relative wavelength assignment, resulting in a residual phase error of 0.25 deg/100 microm. We also demonstrate, for the first time, a quantitative birefringence map of an in vivo human retinal nerve fiber layer.

Entities:  

Mesh:

Year:  2007        PMID: 17867794     DOI: 10.1117/1.2764460

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  38 in total

1.  Master slave en-face OCT/SLO.

Authors:  Adrian Bradu; Konstantin Kapinchev; Frederick Barnes; Adrian Podoleanu
Journal:  Biomed Opt Express       Date:  2015-08-27       Impact factor: 3.732

2.  Snapshot 3D optical coherence tomography system using image mapping spectrometry.

Authors:  Thuc-Uyen Nguyen; Mark C Pierce; Laura Higgins; Tomasz S Tkaczyk
Journal:  Opt Express       Date:  2013-06-03       Impact factor: 3.894

3.  Real-time and high-performance calibration method for high-speed swept-source optical coherence tomography.

Authors:  Ehsan Azimi; Bin Liu; Mark E Brezinski
Journal:  J Biomed Opt       Date:  2010 Jan-Feb       Impact factor: 3.170

4.  Adaptive optics optical coherence tomography at 1 MHz.

Authors:  Omer P Kocaoglu; Timothy L Turner; Zhuolin Liu; Donald T Miller
Journal:  Biomed Opt Express       Date:  2014-11-06       Impact factor: 3.732

5.  Spectrometer calibration for spectroscopic Fourier domain optical coherence tomography.

Authors:  Maciej Szkulmowski; Szymon Tamborski; Maciej Wojtkowski
Journal:  Biomed Opt Express       Date:  2016-11-09       Impact factor: 3.732

Review 6.  Polarization sensitive optical coherence tomography - a review [Invited].

Authors:  Johannes F de Boer; Christoph K Hitzenberger; Yoshiaki Yasuno
Journal:  Biomed Opt Express       Date:  2017-02-24       Impact factor: 3.732

7.  Adaptive optics optical coherence tomography angiography for morphometric analysis of choriocapillaris [Invited].

Authors:  Kazuhiro Kurokawa; Zhuolin Liu; Donald T Miller
Journal:  Biomed Opt Express       Date:  2017-02-24       Impact factor: 3.732

8.  Longitudinal, quantitative monitoring of therapeutic response in 3D in vitro tumor models with OCT for high-content therapeutic screening.

Authors:  O J Klein; Y K Jung; C L Evans
Journal:  Methods       Date:  2013-09-03       Impact factor: 3.608

9.  Polarization maintaining fiber based ultra-high resolution spectral domain polarization sensitive optical coherence tomography.

Authors:  Erich Götzinger; Bernhard Baumann; Michael Pircher; Christoph K Hitzenberger
Journal:  Opt Express       Date:  2009-12-07       Impact factor: 3.894

10.  Real-time processing for Fourier domain optical coherence tomography using a field programmable gate array.

Authors:  Teoman E Ustun; Nicusor V Iftimia; R Daniel Ferguson; Daniel X Hammer
Journal:  Rev Sci Instrum       Date:  2008-11       Impact factor: 1.523

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.