Literature DB >> 25544948

Calibration-free coronary artery measurements for interventional device sizing using inverse geometry x-ray fluoroscopy: in vivo validation.

Michael T Tomkowiak1, Amish N Raval2, Michael S Van Lysel3, Tobias Funk4, Michael A Speidel3.   

Abstract

Proper sizing of interventional devices to match coronary vessel dimensions improves procedural efficiency and therapeutic outcomes. We have developed a method that uses an inverse geometry x-ray fluoroscopy system [scanning beam digital x-ray (SBDX)] to automatically determine vessel dimensions from angiograms without the need for magnification calibration or optimal views. For each frame period (1/15th of a second), SBDX acquires a sequence of narrow beam projections and performs digital tomosynthesis at multiple plane positions. A three-dimensional model of the vessel is reconstructed by localizing the depth of the vessel edges from the tomosynthesis images, and the model is used to calculate the length and diameter in units of millimeters. The in vivo algorithm performance was evaluated in a healthy porcine model by comparing end-diastolic length and diameter measurements from SBDX to coronary computed tomography angiography (CCTA) and intravascular ultrasound (IVUS), respectively. The length error was -0.49 ± 1.76 mm(SBDX- CCTA, mean ± 1 SD). The diameter error was 0.07 ± 0.27 mm (SBDX - minimum IVUS diameter, mean ± 1 SD). The in vivo agreement between SBDX-based vessel sizing and gold standard techniques supports the feasibility of calibration-free coronary vessel sizing using inverse geometry x-ray fluoroscopy.

Entities:  

Keywords:  cardiac interventions; inverse geometry; quantitative coronary angiography; x-ray fluoroscopy

Year:  2014        PMID: 25544948      PMCID: PMC4275130          DOI: 10.1117/1.JMI.1.3.033504

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  50 in total

1.  Automated analysis of coronary arterial morphology in cineangiograms: geometric and physiologic validation in humans.

Authors:  S R Fleagle; M R Johnson; C J Wilbricht; D J Skorton; R F Wilson; C W White; M L Marcus; S M Collins
Journal:  IEEE Trans Med Imaging       Date:  1989       Impact factor: 10.048

2.  Calibration-free device sizing using an inverse geometry x-ray system.

Authors:  Michael T Tomkowiak; Michael A Speidel; Amish N Raval; Michael S Van Lysel
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

3.  Morphometric analysis in three-dimensional intracoronary ultrasound: an in vitro and in vivo study performed with a novel system for the contour detection of lumen and plaque.

Authors:  C von Birgelen; C Di Mario; W Li; J C Schuurbiers; C J Slager; P J de Feyter; J R Roelandt; P W Serruys
Journal:  Am Heart J       Date:  1996-09       Impact factor: 4.749

4.  Parameters that influence accuracy and precision of quantitative coronary arteriography.

Authors:  G Finet; J Liénard
Journal:  Int J Card Imaging       Date:  1996-12

5.  Automated quantitative coronary arteriography: morphologic and physiologic validation in vivo of a rapid digital angiographic method.

Authors:  G B Mancini; S B Simon; M J McGillem; M T LeFree; H Z Friedman; R A Vogel
Journal:  Circulation       Date:  1987-02       Impact factor: 29.690

6.  A fast poly-energetic iterative FBP algorithm.

Authors:  Yuan Lin; Ehsan Samei
Journal:  Phys Med Biol       Date:  2014-03-10       Impact factor: 3.609

7.  Multidetector-row computed tomography vs. angiography and intravascular ultrasound for the evaluation of the diameter of proximal coronary arteries.

Authors:  Anil-Martin Sinha; Andreas H Mahnken; Anja Borghans; Stefan Krüger; Ralf Koos; Katrin Dedden; Joachim E Wildberger; Rainer Hoffmann
Journal:  Int J Cardiol       Date:  2005-09-19       Impact factor: 4.164

8.  Evaluation of coronary atherosclerosis by multislice computed tomography in patients with acute myocardial infarction and without significant coronary artery stenosis: a comparative study with quantitative coronary angiography.

Authors:  Annachiara Aldrovandi; Filippo Cademartiri; Alberto Menozzi; Fabrizio Ugo; Daniela Lina; Erica Maffei; Alessandro Palumbo; Michele Fusaro; Girolamo Crisi; Diego Ardissino
Journal:  Circ Cardiovasc Imaging       Date:  2008-11       Impact factor: 7.792

9.  Influence of inflation pressure and balloon size on the development of intimal hyperplasia after balloon angioplasty. A study in the atherosclerotic rabbit.

Authors:  I J Sarembock; P J LaVeau; S L Sigal; I Timms; J Sussman; C Haudenschild; M D Ezekowitz
Journal:  Circulation       Date:  1989-10       Impact factor: 29.690

10.  Influence of balloon size on initial success, acute complications, and restenosis after percutaneous transluminal coronary angioplasty. A prospective randomized study.

Authors:  G S Roubin; J S Douglas; S B King; S F Lin; N Hutchison; R G Thomas; A R Gruentzig
Journal:  Circulation       Date:  1988-09       Impact factor: 29.690

View more
  5 in total

1.  Depth-resolved registration of transesophageal echo to x-ray fluoroscopy using an inverse geometry fluoroscopy system.

Authors:  Charles R Hatt; Michael T Tomkowiak; David A P Dunkerley; Jordan M Slagowski; Tobias Funk; Amish N Raval; Michael A Speidel
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

2.  Localization of cardiac volume and patient features in inverse geometry x-ray fluoroscopy.

Authors:  Michael A Speidel; Jordan M Slagowski; David A P Dunkerley; Martin Wagner; Tobias Funk; Amish N Raval
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09

3.  Detector, collimator and real-time reconstructor for a new scanning-beam digital x-ray (SBDX) prototype.

Authors:  Michael A Speidel; Michael T Tomkowiak; Amish N Raval; David A P Dunkerley; Jordan M Slagowski; Paul Kahn; Jamie Ku; Tobias Funk
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015

4.  A geometric calibration method for inverse geometry computed tomography using P-matrices.

Authors:  Jordan M Slagowski; David A P Dunkerley; Charles R Hatt; Michael A Speidel
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-22

5.  Single-view geometric calibration for C-arm inverse geometry CT.

Authors:  Jordan M Slagowski; David A P Dunkerley; Charles R Hatt; Michael A Speidel
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-20
  5 in total