Literature DB >> 2970337

Influence of balloon size on initial success, acute complications, and restenosis after percutaneous transluminal coronary angioplasty. A prospective randomized study.

G S Roubin1, J S Douglas, S B King, S F Lin, N Hutchison, R G Thomas, A R Gruentzig.   

Abstract

Restenosis after percutaneous transluminal coronary angioplasty (PTCA) is strongly associated with incomplete initial dilatation. To determine if oversized PTCA balloons would reduce the restenosis rate without increasing the risk of arterial dissection and acute complications, we prospectively randomized 336 patients to receive either smaller or larger balloons. Thirty-four percent of patients had multivessel disease and 18% had multisite dilatation. One hundred sixty-nine patients were randomized to PTCA with a larger balloon and 167 to PTCA with a smaller balloon. Balloon:artery diameter ratios were 1.13 +/- 0.14 in the larger group and 0.93 +/- 0.12 in the smaller group (p less than 0.001). The trial was halted as clinically important differences in acute complications emerged. Emergency bypass graft surgery, usually for the treatment of arterial dissection, was required in 7.1% of patients in the larger balloon group and 3.6% of patients in the smaller balloon group (p = 0.15). Myocardial infarction (Q wave and non-Q wave) complicated 7.7% of procedures in which large balloons were assigned and 3.0% of procedures in which small balloons were assigned (p = 0.056). There were no deaths in either group. The incidence of bypass surgery was 1.7% when the balloon:artery ratio was less than 0.9, 3.1% when the ratio was 0.9-1.1, and 7.8% when it was greater than 1.1. Stepwise logistic regression analysis demonstrated that larger balloon assignment, multiple lesion dilatation, and multivessel coronary artery disease were independent predictors of emergency surgery. Angiographic restudy rates were 50% in the larger group and 60% in the smaller group (p = NS).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1988        PMID: 2970337     DOI: 10.1161/01.cir.78.3.557

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  16 in total

Review 1.  Percutaneous transluminal coronary angioplasty: catheter technology and procedural guidelines.

Authors:  A D Timmis
Journal:  Br Heart J       Date:  1990-07

Review 2.  Cardiology.

Authors:  L D Smith; D J Coltart
Journal:  Postgrad Med J       Date:  1990-04       Impact factor: 2.401

3.  Calibration-free device sizing using an inverse geometry x-ray system.

Authors:  Michael T Tomkowiak; Michael A Speidel; Amish N Raval; Michael S Van Lysel
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

4.  The impact of vessel and catheter position on the measurement accuracy in catheter-based quantitative coronary angiography.

Authors:  W Wunderlich; B Roehrig; F Fischer; H R Arntz; R Agrawal; A Morguet; H P Schultheiss; D Horstkotte
Journal:  Int J Card Imaging       Date:  1998-08

5.  Overaggressive stent expansion without intravascular imaging: impact on restenosis.

Authors:  Yohan Chacko; Richard Chan; J Kimberly Haladyn; Richard Lim
Journal:  Heart Asia       Date:  2014-02-27

6.  Calibration-free coronary artery measurements for interventional device sizing using inverse geometry x-ray fluoroscopy: in vivo validation.

Authors:  Michael T Tomkowiak; Amish N Raval; Michael S Van Lysel; Tobias Funk; Michael A Speidel
Journal:  J Med Imaging (Bellingham)       Date:  2014-10

7.  IVUS-Guided Stent Implantation to Improve Outcome: A Promise Waiting to be Fulfilled.

Authors:  Renata Rogacka; Azeem Latib; Antonio Colombo
Journal:  Curr Cardiol Rev       Date:  2009-05

8.  Calibration-Free Coronary Artery Measurements for Interventional Device Sizing using Inverse Geometry X-ray Fluoroscopy: In Vivo Validation.

Authors:  Michael T Tomkowiak; Amish N Raval; Michael S Van Lysel; Tobias Funk; Michael A Speidel
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-19

9.  Lipid rich plaque, female gender and proximal coronary stent edge dissections.

Authors:  Magdalena Zeglin-Sawczuk; Ik-Kyung Jang; Koji Kato; Taishi Yonetsu; SooJoong Kim; So-Yeon Choi; Christina Kratlian; Hang Lee; Harold L Dauerman
Journal:  J Thromb Thrombolysis       Date:  2013-11       Impact factor: 2.300

10.  Transcatheter coronary artery diagnostic techniques including impedance-catheter and impedance-guidewire measurement of absolute coronary blood flow.

Authors:  R A Vogel; L W Martin
Journal:  Tex Heart Inst J       Date:  1989
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.