A geometric calibration method for inverse geometry computed tomography using P-matrices.

Jordan M Slagowski1, David A P Dunkerley1, Charles R Hatt2, Michael A Speidel3.   

Abstract

Accurate and artifact free reconstruction of tomographic images requires precise knowledge of the imaging system geometry. This work proposes a novel projection matrix (P-matrix) based calibration method to enable C-arm inverse geometry CT (IGCT). The method is evaluated for scanning-beam digital x-ray (SBDX), a C-arm mounted inverse geometry fluoroscopic technology. A helical configuration of fiducials is imaged at each gantry angle in a rotational acquisition. For each gantry angle, digital tomosynthesis is performed at multiple planes and a composite image analogous to a cone-beam projection is generated from the plane stack. The geometry of the C-arm, source array, and detector array is determined at each angle by constructing a parameterized 3D-to-2D projection matrix that minimizes the sum-of-squared deviations between measured and projected fiducial coordinates. Simulations were used to evaluate calibration performance with translations and rotations of the source and detector. In a geometry with 1 mm translation of the central ray relative to the axis-of-rotation and 1 degree yaw of the detector and source arrays, the maximum error in the recovered translational parameters was 0.4 mm and maximum error in the rotation parameter was 0.02 degrees. The relative root-mean-square error in a reconstruction of a numerical thorax phantom was 0.4% using the calibration method, versus 7.7% without calibration. Changes in source-detector-distance were the most challenging to estimate. Reconstruction of experimental SBDX data using the proposed method eliminated double contour artifacts present in a non-calibrated reconstruction. The proposed IGCT geometric calibration method reduces image artifacts when uncertainties exist in system geometry.

Entities:  

Keywords:  C-arm calibration; Inverse geometry; computed tomography; projection matrix; scanning beam digital x-ray

Year:  2016        PMID: 27375313      PMCID: PMC4925097          DOI: 10.1117/12.2216565

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  8 in total

1.  A three-dimensional reconstruction algorithm for an inverse-geometry volumetric CT system.

Authors:  Taly Gilat Schmidt; Rebecca Fahrig; Norbert J Pelc
Journal:  Med Phys       Date:  2005-11       Impact factor: 4.071

2.  Scanning-beam digital x-ray (SBDX) technology for interventional and diagnostic cardiac angiography.

Authors:  Michael A Speidel; Brian P Wilfley; Josh M Star-Lack; Joseph A Heanue; Michael S Van Lysel
Journal:  Med Phys       Date:  2006-08       Impact factor: 4.071

3.  Geometric calibration for a dual tube/detector micro-CT system.

Authors:  Samuel M Johnston; G Allan Johnson; Cristian T Badea
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

4.  Three-dimensional tracking of cardiac catheters using an inverse geometry x-ray fluoroscopy system.

Authors:  Michael A Speidel; Michael T Tomkowiak; Amish N Raval; Michael S Van Lysel
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

5.  Monoplane Stereoscopic Imaging Method for Inverse Geometry X-ray Fluoroscopy.

Authors:  Michael T Tomkowiak; Michael S Van Lysel; Michael A Speidel
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-13

6.  Calibration-free coronary artery measurements for interventional device sizing using inverse geometry x-ray fluoroscopy: in vivo validation.

Authors:  Michael T Tomkowiak; Amish N Raval; Michael S Van Lysel; Tobias Funk; Michael A Speidel
Journal:  J Med Imaging (Bellingham)       Date:  2014-10

7.  Feasibility of CT-based 3D anatomic mapping with a scanning-beam digital x-ray (SBDX) system.

Authors:  Jordan M Slagowski; Michael T Tomkowiak; David A P Dunkerley; Michael A Speidel
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015

8.  Detector, collimator and real-time reconstructor for a new scanning-beam digital x-ray (SBDX) prototype.

Authors:  Michael A Speidel; Michael T Tomkowiak; Amish N Raval; David A P Dunkerley; Jordan M Slagowski; Paul Kahn; Jamie Ku; Tobias Funk
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015
  8 in total
  1 in total

1.  Tomosynthesis implementation with adaptive online calibration on clinical C-arm systems.

Authors:  Khanlian Chung; Lothar R Schad; Frank G Zöllner
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-05-08       Impact factor: 2.924

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.