OBJECTIVE: To evaluate metal artifacts induced by biodegradable magnesium--a new class of degradable biomaterial that is beginning to enter the orthopedic routine--on CT and MRI compared to standard titanium and steel controls.
METHODS: Different pins made of titanium, stainless steel, and biodegradable magnesium alloys were scanned using a second-generation dual-energy multidetector CT and a 1.5-T MR scanner. In CT, quantitative assessment of artifacts was performed by two independent readers by measuring the noise in standardized regions of interest close to the pins. In MRI, the artifact diameter was measured. Interobserver agreement was evaluated using intraclass correlation coefficients. Artifacts were compared using Mann Whitney U tests.
RESULTS: In comparison to stainless steel, biodegradable magnesium alloys induced significantly fewer artifacts in both 1.5-T MRI (p = 0.019-0.021) and CT (p = 0.003-0.006). Compared to titanium, magnesium induced significantly less artifact-related noise in CT (p = 0.003-0.008). Although artifacts were less on MRI for biodegradable magnesium compared to titanium, this result was not statistically significant.
CONCLUSION: Biodegradable magnesium alloys induce substantially fewer artifacts in CT compared to standard titanium and stainless steel, and fewer artifacts in MRI for the comparison with stainless steel.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25417003     DOI: 10.1007/s00256-014-2057-5

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  29 in total

1.  Imaging near metal with a MAVRIC-SEMAC hybrid.

Authors:  K M Koch; A C Brau; W Chen; G E Gold; B A Hargreaves; M Koff; G C McKinnon; H G Potter; K F King
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

2.  In vitro and in vivo corrosion measurements of magnesium alloys.

Authors:  Frank Witte; Jens Fischer; Jens Nellesen; Horst-Artur Crostack; Volker Kaese; Alexander Pisch; Felix Beckmann; Henning Windhagen
Journal:  Biomaterials       Date:  2005-08-24       Impact factor: 12.479

3.  A novel forward projection-based metal artifact reduction method for flat-detector computed tomography.

Authors:  Daniel Prell; Yiannis Kyriakou; Marcel Beister; Willi A Kalender
Journal:  Phys Med Biol       Date:  2009-10-14       Impact factor: 3.609

4.  Reduction of metal artifacts in patients with total hip arthroplasty with slice-encoding metal artifact correction and view-angle tilting MR imaging.

Authors:  Reto Sutter; Erika J Ulbrich; Vladimir Jellus; Mathias Nittka; Christian W A Pfirrmann
Journal:  Radiology       Date:  2012-08-24       Impact factor: 11.105

Review 5.  Magnesium and its alloys as orthopedic biomaterials: a review.

Authors:  Mark P Staiger; Alexis M Pietak; Jerawala Huadmai; George Dias
Journal:  Biomaterials       Date:  2005-10-24       Impact factor: 12.479

Review 6.  The history of biodegradable magnesium implants: a review.

Authors:  Frank Witte
Journal:  Acta Biomater       Date:  2010-02-19       Impact factor: 8.947

7.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

Review 8.  Metal artifact reduction in musculoskeletal magnetic resonance imaging.

Authors:  Craig A Harris; Lawrence M White
Journal:  Orthop Clin North Am       Date:  2006-07       Impact factor: 2.472

9.  Corrosion resistance of a composite polymeric coating applied on biodegradable AZ31 magnesium alloy.

Authors:  A Zomorodian; M P Garcia; T Moura e Silva; J C S Fernandes; M H Fernandes; M F Montemor
Journal:  Acta Biomater       Date:  2013-02-28       Impact factor: 8.947

10.  A surface-eroding poly(1,3-trimethylene carbonate) coating for fully biodegradable magnesium-based stent applications: toward better biofunction, biodegradation and biocompatibility.

Authors:  Juan Wang; Yonghui He; Manfred F Maitz; Boyce Collins; Kaiqin Xiong; Lisha Guo; Yeoheung Yun; Guojiang Wan; Nan Huang
Journal:  Acta Biomater       Date:  2013-03-01       Impact factor: 8.947

View more
  9 in total

1.  What is the Diagnostic Accuracy of MRI for Component Loosening in THA?

Authors:  Alissa J Burge; Gabrielle P Konin; Jennifer L Berkowitz; Bin Lin; Matthew F Koff; Hollis G Potter
Journal:  Clin Orthop Relat Res       Date:  2019-09       Impact factor: 4.176

2.  Evaluation and reduction of magnetic resonance imaging artefacts induced by distinct plates for osseous fixation: an in vitro study @ 3 T.

Authors:  Carsten Rendenbach; Max Schoellchen; Julie Bueschel; Tobias Gauer; Jan Sedlacik; Daniel Kutzner; Pekka K Vallittu; Max Heiland; Ralf Smeets; Jens Fiehler; Susanne Siemonsen
Journal:  Dentomaxillofac Radiol       Date:  2018-05-23       Impact factor: 2.419

3.  Biodegradable magnesium Herbert screw - image quality and artifacts with radiography, CT and MRI.

Authors:  Lena Sonnow; Sören Könneker; Peter M Vogt; Frank Wacker; Christian von Falck
Journal:  BMC Med Imaging       Date:  2017-02-14       Impact factor: 1.930

4.  Biodegradable Surgical Staple Composed of Magnesium Alloy.

Authors:  Hizuru Amano; Kotaro Hanada; Akinari Hinoki; Takahisa Tainaka; Chiyoe Shirota; Wataru Sumida; Kazuki Yokota; Naruhiko Murase; Kazuo Oshima; Kosuke Chiba; Yujiro Tanaka; Hiroo Uchida
Journal:  Sci Rep       Date:  2019-10-11       Impact factor: 4.379

5.  In vitro and in vivo biocompatibility of Mg-Zn-Ca alloy operative clip.

Authors:  Pengfei Ding; Yuanchao Liu; Xianghui He; Debao Liu; Minfang Chen
Journal:  Bioact Mater       Date:  2019-08-05

6.  Alterations in magnetic resonance imaging characteristics of bioabsorbable magnesium screws over time in humans: a retrospective single center study.

Authors:  Lena Sonnow; Andreas Ziegler; Gesa H Pöhler; Martin H Kirschner; Maximilian Richter; Mustafa Cetin; Melih Unal; Ozkan Kose
Journal:  Innov Surg Sci       Date:  2021-12-23

7.  Evaluating metallic artefact of biodegradable magnesium-based implants in magnetic resonance imaging.

Authors:  Jonathan Espiritu; Mostafa Berangi; Christina Yiannakou; Eduarda Silva; Roberto Francischello; Andre Kuehne; Thoralf Niendorf; Sören Könneker; Regine Willumeit-Römer; Jan-Marten Seitz
Journal:  Bioact Mater       Date:  2022-01-06

Review 8.  Corrosion Behavior in Magnesium-Based Alloys for Biomedical Applications.

Authors:  Liming Xu; Xingwang Liu; Kang Sun; Rao Fu; Gang Wang
Journal:  Materials (Basel)       Date:  2022-04-01       Impact factor: 3.623

9.  Rotator cuff repair with biodegradable high-purity magnesium suture anchor in sheep model.

Authors:  Yudie Chen; Yu Sun; Xinhui Wu; Jie Lou; Xiaonong Zhang; Zhaoxiang Peng
Journal:  J Orthop Translat       Date:  2022-09-10       Impact factor: 4.889

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.