Literature DB >> 25378035

Catheter-tissue contact force values do not impact mid-term clinical outcome following pulmonary vein isolation in patients with paroxysmal atrial fibrillation.

Giuseppe Stabile1, Francesco Solimene, Leonardo Calò, Matteo Anselmino, Antonello Castro, Claudio Pratola, Paolo Golia, Nicola Bottoni, Giuseppe Grandinetti, Antonio De Simone, Vincenzo Schillaci, Emanuele Bertaglia, Roberto De Ponti.   

Abstract

PURPOSE: Catheter-tissue contact is critical for effective lesion creation in radiofrequency catheter ablation (RFCA). In a multicenter prospective study, we assessed the relationship between catheter contact force (CF) during RFCA for paroxysmal atrial fibrillation (AF) and clinical recurrences over a mid-term follow-up.
METHODS: All patients underwent RFCA for paroxysmal AF by antral pulmonary vein (PV) isolation, aiming at entry and exit conduction block in all PVs. A new open-irrigated tip catheter with CF sensing (SmartTouch(TM), Biosense Webster Inc. CA) was used. All patients were followed for at least 12 months and the relationship between CF and clinical outcomes assessed.
RESULTS: One year follow-up was available in 92/95 of the patients enrolled. Acute PV isolation was achieved in 100 % of the veins. Mean CF during RFCA was 12.2 ± 3.9 g. Mean force-time integral (FTI) was 733 ± 505 gs. Following the 3-month blanking period, 17 (18 %) patients experienced at least 1 atrial tachyarrhythmia relapse. There was no statistical difference in mean CF (13 ± 3.4 g vs 12 ± 4 g, p = 0.32) and mean FTI (713 ± 487 gs vs 822 ± 590 gs, p = 0.42) between patients with and without arrhythmia recurrences. Recurrences were recorded in 22 % of patients achieving a mean FTI value below the median of 544 gs and in 15 % of patients with a mean FTI value above the median (p = 0.64).
CONCLUSIONS: RFCA with CF data during PV isolation for paroxysmal AF improves physician's knowledge on catheter-tissue contact. In the present dataset, however, higher CF values did not impact mid-term clinical RFCA outcome.

Entities:  

Mesh:

Year:  2014        PMID: 25378035     DOI: 10.1007/s10840-014-9947-2

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  16 in total

1.  The effects of electrode-tissue contact on radiofrequency lesion generation.

Authors:  B Avitall; K Mughal; J Hare; R Helms; D Krum
Journal:  Pacing Clin Electrophysiol       Date:  1997-12       Impact factor: 1.976

2.  Safety of the open-irrigated ablation catheter for radiofrequency ablation: safety analysis from six clinical studies.

Authors:  Albert L Waldo; David J Wilber; Francis E Marchlinski; William G Stevenson; Brenda Aker; Lee Ming Boo; Warren M Jackman
Journal:  Pacing Clin Electrophysiol       Date:  2012-07-22       Impact factor: 1.976

3.  The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study.

Authors:  Vivek Y Reddy; Dipen Shah; Josef Kautzner; Boris Schmidt; Nadir Saoudi; Claudia Herrera; Pierre Jaïs; Gerhard Hindricks; Petr Peichl; Aude Yulzari; Hendrik Lambert; Petr Neuzil; Andrea Natale; Karl-Heinz Kuck
Journal:  Heart Rhythm       Date:  2012-07-20       Impact factor: 6.343

4.  Predictive value of early atrial tachyarrhythmias recurrence after circumferential anatomical pulmonary vein ablation.

Authors:  Emanuele Bertaglia; Giuseppe Stabile; Gaetano Senatore; Franco Zoppo; Pietro Turco; Claudia Amellone; Antonio De Simone; Massimo Fazzari; Pietro Pascotto
Journal:  Pacing Clin Electrophysiol       Date:  2005-05       Impact factor: 1.976

5.  Impact of ablation catheter irrigation design on silent cerebral embolism after radiofrequency catheter ablation of atrial fibrillation: results from a pilot study.

Authors:  Marco Scaglione; Alessandro Blandino; Cristina Raimondo; Domenico Caponi; Paolo Di Donna; Elisabetta Toso; Elisa Ebrille; Federico Cesarani; Eva Ferrarese; Fiorenzo Gaita
Journal:  J Cardiovasc Electrophysiol       Date:  2012-04-11

6.  Reduced fluoroscopy exposure during ablation of atrial fibrillation using a novel electroanatomical navigation system: a multicentre experience.

Authors:  Giuseppe Stabile; Marco Scaglione; Maurizio del Greco; Roberto De Ponti; Maria Grazia Bongiorni; Franco Zoppo; Ezio Soldati; Raffaella Marazzi; Massimiliano Marini; Fiorenzo Gaita; Assunta Iuliano; Emanuele Bertaglia
Journal:  Europace       Date:  2011-09-04       Impact factor: 5.214

7.  Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter.

Authors:  Aravinda Thiagalingam; Andre D'Avila; Lori Foley; J Luis Guerrero; Hendrik Lambert; Giovanni Leo; Jeremy N Ruskin; Vivek Y Reddy
Journal:  J Cardiovasc Electrophysiol       Date:  2010-02-01

8.  Mechanisms of pulmonary vein reconnection after radiofrequency ablation of atrial fibrillation: the deterministic role of contact force and interlesion distance.

Authors:  Chan-Il Park; Heiko Lehrmann; Cornelius Keyl; Reinhold Weber; Jochen Schiebeling; Juergen Allgeier; Patrick Schurr; Ashok Shah; Franz-Josef Neumann; Thomas Arentz; Amir S Jadidi
Journal:  J Cardiovasc Electrophysiol       Date:  2014-04-02

9.  Contact force sensing technology identifies sites of inadequate contact and reduces acute pulmonary vein reconnection: a prospective case control study.

Authors:  Shouvik Haldar; Julian W E Jarman; Sandeep Panikker; David G Jones; Tushar Salukhe; Dhiraj Gupta; Gareth Wynn; Wajid Hussain; Vias Markides; Tom Wong
Journal:  Int J Cardiol       Date:  2012-12-04       Impact factor: 4.164

10.  Catheter-tissue contact force for pulmonary veins isolation: a pilot multicentre study on effect on procedure and fluoroscopy time.

Authors:  Giuseppe Stabile; Francesco Solimene; Leonardo Calò; Matteo Anselmino; Antonello Castro; Claudio Pratola; Paolo Golia; Nicola Bottoni; Giuseppe Grandinetti; Antonio De Simone; Roberto De Ponti; Serena Dottori; Emanuele Bertaglia
Journal:  Europace       Date:  2013-12-12       Impact factor: 5.214

View more
  9 in total

1.  Contact force monitoring during catheter ablation of intraatrial reentrant tachycardia in patients with congenital heart disease.

Authors:  Ulrich Krause; David Backhoff; Sophia Klehs; Heike E Schneider; Thomas Paul
Journal:  J Interv Card Electrophysiol       Date:  2016-01-07       Impact factor: 1.900

2.  Clinical experience with contact-force and flexible-tip ablation catheter designs.

Authors:  N Deubner; H Greiss; E Akkaya; A Berkowitsch; S Zaltsberg; C W Hamm; M Kuniss; T Neumann
Journal:  J Interv Card Electrophysiol       Date:  2016-03-31       Impact factor: 1.900

3.  Evolution of Force Sensing Technologies.

Authors:  Dipen Shah
Journal:  Arrhythm Electrophysiol Rev       Date:  2017-06

Review 4.  [Catheter ablation : Developments and technique selection].

Authors:  L Yahsaly; J Siebermair; R Wakili
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2022-02-18

5.  The best of two worlds? Pulmonary vein isolation using a novel radiofrequency ablation catheter incorporating contact force sensing technology and 56-hole porous tip irrigation.

Authors:  Tilman Maurer; Laura Rottner; Hisaki Makimoto; Bruno Reissmann; Christian-H Heeger; Christine Lemes; Thomas Fink; Johannes Riedl; Francesco Santoro; Peter Wohlmuth; Marius Volkmer; Shibu Mathew; Andreas Metzner; Feifan Ouyang; Karl-Heinz Kuck; Christian Sohns
Journal:  Clin Res Cardiol       Date:  2018-05-08       Impact factor: 5.460

Review 6.  Contact force-guided catheter ablation for the treatment of atrial fibrillation: a meta-analysis of randomized, controlled trials.

Authors:  Z Qi; X Luo; B Wu; H Shi; B Jin; Z Wen
Journal:  Braz J Med Biol Res       Date:  2016-02-02       Impact factor: 2.590

7.  Adjunctive interpulmonary isthmus ablation has no added effects on atrial fibrillation recurrence.

Authors:  Shunichi Higashiya; Hirosuke Yamaji; Takashi Murakami; Kazuyoshi Hina; Hiroshi Kawamura; Masaaki Murakami; Shigeshi Kamikawa; Issei Komatsubara; Shozo Kusachi
Journal:  Open Heart       Date:  2017-03-27

8.  Comparison of the efficacy between impedance-guided and contact force-guided atrial fibrillation ablation using an automated annotation system.

Authors:  Hyoung-Seob Park; In-Cheol Kim; Yun-Kyeong Cho; Hyuck-Jun Yoon; Hyungseop Kim; Chang-Wook Nam; Seongwook Han; Seung-Ho Hur; Yoon-Nyun Kim; Kwon-Bae Kim
Journal:  J Arrhythm       Date:  2018-04-11

Review 9.  Catheter Ablation of Atrial Fibrillation: State of the Art and Future Perspectives.

Authors:  Laura Rottner; Barbara Bellmann; Tina Lin; Bruno Reissmann; Tobias Tönnis; Ruben Schleberger; Moritz Nies; Christiane Jungen; Leon Dinshaw; Niklas Klatt; Jannis Dickow; Paula Münkler; Christian Meyer; Andreas Metzner; Andreas Rillig
Journal:  Cardiol Ther       Date:  2020-01-02
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.