Literature DB >> 25370666

Development and evaluation of convergent and accelerated penalized SPECT image reconstruction methods for improved dose-volume histogram estimation in radiopharmaceutical therapy.

Lishui Cheng1, Robert F Hobbs2, George Sgouros2, Eric C Frey2.   

Abstract

PURPOSE: Three-dimensional (3D) dosimetry has the potential to provide better prediction of response of normal tissues and tumors and is based on 3D estimates of the activity distribution in the patient obtained from emission tomography. Dose-volume histograms (DVHs) are an important summary measure of 3D dosimetry and a widely used tool for treatment planning in radiation therapy. Accurate estimates of the radioactivity distribution in space and time are desirable for accurate 3D dosimetry. The purpose of this work was to develop and demonstrate the potential of penalized SPECT image reconstruction methods to improve DVHs estimates obtained from 3D dosimetry methods.
METHODS: The authors developed penalized image reconstruction methods, using maximum a posteriori (MAP) formalism, which intrinsically incorporate regularization in order to control noise and, unlike linear filters, are designed to retain sharp edges. Two priors were studied: one is a 3D hyperbolic prior, termed single-time MAP (STMAP), and the second is a 4D hyperbolic prior, termed cross-time MAP (CTMAP), using both the spatial and temporal information to control noise. The CTMAP method assumed perfect registration between the estimated activity distributions and projection datasets from the different time points. Accelerated and convergent algorithms were derived and implemented. A modified NURBS-based cardiac-torso phantom with a multicompartment kidney model and organ activities and parameters derived from clinical studies were used in a Monte Carlo simulation study to evaluate the methods. Cumulative dose-rate volume histograms (CDRVHs) and cumulative DVHs (CDVHs) obtained from the phantom and from SPECT images reconstructed with both the penalized algorithms and OS-EM were calculated and compared both qualitatively and quantitatively. The STMAP method was applied to patient data and CDRVHs obtained with STMAP and OS-EM were compared qualitatively.
RESULTS: The results showed that the penalized algorithms substantially improved the CDRVH and CDVH estimates for large organs such as the liver compared to optimally postfiltered OS-EM. For example, the mean squared errors (MSEs) of the CDRVHs for the liver at 5 h postinjection obtained with CTMAP and STMAP were about 15% and 17%, respectively, of the MSEs obtained with optimally filtered OS-EM. For the CDVH estimates, the MSEs obtained with CTMAP and STMAP were about 16% and 19%, respectively, of the MSEs from OS-EM. For the kidneys and renal cortices, larger residual errors were observed for all algorithms, likely due to partial volume effects. The STMAP method showed promising qualitative results when applied to patient data.
CONCLUSIONS: Penalized image reconstruction methods were developed and evaluated through a simulation study. The study showed that the MAP algorithms substantially improved CDVH estimates for large organs such as the liver compared to optimally postfiltered OS-EM reconstructions. For small organs with fine structural detail such as the kidneys, a large residual error was observed for both MAP algorithms and OS-EM. While CTMAP provided marginally better MSEs than STMAP, given the extra effort needed to handle misregistration of images at different time points in the algorithm and the potential impact of residual misregistration, 3D regularization methods, such as that used in STMAP, appear to be a more practical choice.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25370666      PMCID: PMC4241887          DOI: 10.1118/1.4897613

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  42 in total

Review 1.  Radiotherapy with internal emitters: what can dosimetrists offer?

Authors:  Michael G Stabin
Journal:  Cancer Biother Radiopharm       Date:  2003-08       Impact factor: 3.099

2.  Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function.

Authors:  X Song; W P Segars; Y Du; B M W Tsui; E C Frey
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

3.  A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography.

Authors:  A R De Pierro
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

4.  Calculation of normal tissue complication probability and dose-volume histogram reduction schemes for tissues with a critical element architecture.

Authors:  A Niemierko; M Goitein
Journal:  Radiother Oncol       Date:  1991-03       Impact factor: 6.280

Review 5.  Radioimmunotherapy of B-cell non-Hodgkin's lymphoma: from clinical trials to clinical practice.

Authors:  Malik E Juweid
Journal:  J Nucl Med       Date:  2002-11       Impact factor: 10.057

6.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

7.  Regularized reconstruction in quantitative SPECT using CT side information from hybrid imaging.

Authors:  Yuni K Dewaraja; Kenneth F Koral; Jeffrey A Fessler
Journal:  Phys Med Biol       Date:  2010-04-14       Impact factor: 3.609

8.  Regularized image reconstruction algorithms for dual-isotope myocardial perfusion SPECT (MPS) imaging using a cross-tracer prior.

Authors:  Xin He; Lishui Cheng; Jeffrey A Fessler; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2010-10-14       Impact factor: 10.048

9.  A treatment planning method for sequentially combining radiopharmaceutical therapy and external radiation therapy.

Authors:  Robert F Hobbs; Todd McNutt; Sébastien Baechler; Bin He; Caroline E Esaias; Eric C Frey; David M Loeb; Richard L Wahl; Ori Shokek; George Sgouros
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-10-13       Impact factor: 7.038

10.  Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation.

Authors:  Yuni K Dewaraja; Scott J Wilderman; Michael Ljungberg; Kenneth F Koral; Kenneth Zasadny; Mark S Kaminiski
Journal:  J Nucl Med       Date:  2005-05       Impact factor: 10.057

View more
  1 in total

1.  A no-gold-standard technique for objective assessment of quantitative nuclear-medicine imaging methods.

Authors:  Abhinav K Jha; Brian Caffo; Eric C Frey
Journal:  Phys Med Biol       Date:  2016-03-16       Impact factor: 3.609

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.