Literature DB >> 26982626

A no-gold-standard technique for objective assessment of quantitative nuclear-medicine imaging methods.

Abhinav K Jha1, Brian Caffo, Eric C Frey.   

Abstract

The objective optimization and evaluation of nuclear-medicine quantitative imaging methods using patient data is highly desirable but often hindered by the lack of a gold standard. Previously, a regression-without-truth (RWT) approach has been proposed for evaluating quantitative imaging methods in the absence of a gold standard, but this approach implicitly assumes that bounds on the distribution of true values are known. Several quantitative imaging methods in nuclear-medicine imaging measure parameters where these bounds are not known, such as the activity concentration in an organ or the volume of a tumor. We extended upon the RWT approach to develop a no-gold-standard (NGS) technique for objectively evaluating such quantitative nuclear-medicine imaging methods with patient data in the absence of any ground truth. Using the parameters estimated with the NGS technique, a figure of merit, the noise-to-slope ratio (NSR), can be computed, which can rank the methods on the basis of precision. An issue with NGS evaluation techniques is the requirement of a large number of patient studies. To reduce this requirement, the proposed method explored the use of multiple quantitative measurements from the same patient, such as the activity concentration values from different organs in the same patient. The proposed technique was evaluated using rigorous numerical experiments and using data from realistic simulation studies. The numerical experiments demonstrated that the NSR was estimated accurately using the proposed NGS technique when the bounds on the distribution of true values were not precisely known, thus serving as a very reliable metric for ranking the methods on the basis of precision. In the realistic simulation study, the NGS technique was used to rank reconstruction methods for quantitative single-photon emission computed tomography (SPECT) based on their performance on the task of estimating the mean activity concentration within a known volume of interest. Results showed that the proposed technique provided accurate ranking of the reconstruction methods for 97.5% of the 50 noise realizations. Further, the technique was robust to the choice of evaluated reconstruction methods. The simulation study pointed to possible violations of the assumptions made in the NGS technique under clinical scenarios. However, numerical experiments indicated that the NGS technique was robust in ranking methods even when there was some degree of such violation.

Entities:  

Mesh:

Year:  2016        PMID: 26982626      PMCID: PMC4921224          DOI: 10.1088/0031-9155/61/7/2780

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  27 in total

1.  A Monte Carlo and physical phantom evaluation of quantitative In-111 SPECT.

Authors:  Bin He; Yong Du; Xiyun Song; W Paul Segars; Eric C Frey
Journal:  Phys Med Biol       Date:  2005-08-24       Impact factor: 3.609

2.  Quantitative SPECT/CT: SPECT joins PET as a quantitative imaging modality.

Authors:  Dale L Bailey; Kathy P Willowson
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-09-14       Impact factor: 9.236

Review 3.  Quantitative Assessment of Myocardial Blood Flow with SPECT.

Authors:  Mario Petretta; Giovanni Storto; Teresa Pellegrino; Domenico Bonaduce; Alberto Cuocolo
Journal:  Prog Cardiovasc Dis       Date:  2015-01-03       Impact factor: 8.194

Review 4.  An evidence-based review of quantitative SPECT imaging and potential clinical applications.

Authors:  Dale L Bailey; Kathy P Willowson
Journal:  J Nucl Med       Date:  2013-01       Impact factor: 10.057

5.  Towards quantitative myocardial perfusion PET in the clinic.

Authors:  Arman Rahmim; Abdel K Tahari; Thomas H Schindler
Journal:  J Am Coll Radiol       Date:  2014-04       Impact factor: 5.532

6.  Development and evaluation of convergent and accelerated penalized SPECT image reconstruction methods for improved dose-volume histogram estimation in radiopharmaceutical therapy.

Authors:  Lishui Cheng; Robert F Hobbs; George Sgouros; Eric C Frey
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

7.  Evaluating segmentation algorithms for diffusion-weighted MR images: a task-based approach.

Authors:  Abhinav K Jha; Matthew A Kupinski; Jeffrey J Rodríguez; Renu M Stephen; Alison T Stopeck
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010-02-27

8.  Comparing cardiac ejection fraction estimation algorithms without a gold standard.

Authors:  Matthew A Kupinski; John W Hoppin; Joshua Krasnow; Seth Dahlberg; Jeffrey A Leppo; Michael A King; Eric Clarkson; Harrison H Barrett
Journal:  Acad Radiol       Date:  2006-03       Impact factor: 3.173

9.  Evaluation of a method for activity estimation in Sm-153 EDTMP imaging.

Authors:  Eleonora Vanzi; Dario Genovesi; Fabio Di Martino
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

10.  Whole-body SPECT/CT for bone scintigraphy: diagnostic value and effect on patient management in oncological patients.

Authors:  H Palmedo; C Marx; A Ebert; B Kreft; Y Ko; A Türler; R Vorreuther; U Göhring; H H Schild; T Gerhardt; U Pöge; S Ezziddin; H-J Biersack; H Ahmadzadehfar
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-08-24       Impact factor: 9.236

View more
  6 in total

1.  Bayesian framework inspired no-reference region-of-interest quality measure for brain MRI images.

Authors:  Michael Osadebey; Marius Pedersen; Douglas Arnold; Katrina Wendel-Mitoraj
Journal:  J Med Imaging (Bellingham)       Date:  2017-06-13

2.  No-gold-standard evaluation of image-acquisition methods using patient data.

Authors:  Abhinav K Jha; Eric Frey
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-10

3.  Practical no-gold-standard evaluation framework for quantitative imaging methods: application to lesion segmentation in positron emission tomography.

Authors:  Abhinav K Jha; Esther Mena; Brian Caffo; Saeed Ashrafinia; Arman Rahmim; Eric Frey; Rathan M Subramaniam
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-03

4.  A physics and learning-based transmission-less attenuation compensation method for SPECT.

Authors:  Zitong Yu; Md Ashequr Rahman; Thomas Schindler; Richard Laforest; Abhinav K Jha
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-15

5.  Task-based assessment of binned and list-mode SPECT systems.

Authors:  Md Ashequr Rahman; Abhinav K Jha
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-15

6.  A LIST-MODE OSEM-BASED ATTENUATION AND SCATTER COMPENSATION METHOD FOR SPECT.

Authors:  Md Ashequr Rahman; Richard Laforest; Abhinav K Jha
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2020-05-22
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.