Literature DB >> 21381484

A new formulation for the prediction of polyethylene wear in artificial hip joints.

F Liu1, A Galvin, Z Jin, J Fisher.   

Abstract

Artificial joints employing ultra-high molecular weight polyethylene (UHMWPE) are widely used to treat joint diseases and trauma. Wear of the polymer bearing surface largely limits the use of these joints in younger and more active patients. Previous studies have shown the wear factor used in Archard's law for the conventional polyethylene to be highly dependent on contact pressure and this has produced variability in experimental data and has constrained the reliability and applicability of previous computational predictions. A new wear law is proposed, based on wear volume being dependent on, and proportional to, the product of the sliding distance and contact area. The dimensionless proportional constant, wear coefficient, which was independent of contact pressure, was determined from a multi-directional pin on plate study. This was used in computational predictions of the wear of the conventional UHMWPE hip joints. The wear of the polyethylene cup was independently experimentally determined in physiological full hip joint simulator studies. The predicted wear rate from the new computational model was generally increased, with an improved agreement with the experimental measurement compared with the previous computational model. It was shown that wear in the UHMWPE hip joints increased as head size and contact area increased. This resulted in a much larger increase in the wear rate as the head size increased, compared with the previous computational model, and is consistent with clinical observations. This new understanding of the wear mechanism in artificial joints using the UHMWPE bearing surfaces, and the improved ability to predict wear independently and to address previously described discrepancies offer new opportunities to optimize design parameters.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21381484     DOI: 10.1243/09544119JEIM819

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  7 in total

1.  Computational analysis of polyethylene wear in anatomical and reverse shoulder prostheses.

Authors:  C Quental; J Folgado; P R Fernandes; J Monteiro
Journal:  Med Biol Eng Comput       Date:  2014-11-02       Impact factor: 2.602

2.  Wear performance of inverted non-conforming bearings in anatomic total shoulder arthroplasty.

Authors:  Lorenzo Banci; Alessio Meoli; Martin Hintner; Hans Rudolf Bloch
Journal:  Shoulder Elbow       Date:  2019-02-07

3.  Effect of motion inputs on the wear prediction of artificial hip joints.

Authors:  Feng Liu; John Fisher; Zhongmin Jin
Journal:  Tribol Int       Date:  2013-07       Impact factor: 4.872

4.  The influence of simulator input conditions on the wear of total knee replacements: An experimental and computational study.

Authors:  Claire L Brockett; Abdellatif Abdelgaied; Tony Haythornthwaite; Catherine Hardaker; John Fisher; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2016-05       Impact factor: 1.617

5.  Computational wear of knee implant polyethylene insert surface under continuous dynamic loading and posterior tibial slope variation based on cadaver experiments with comparative verification.

Authors:  Alaettin Ozer
Journal:  BMC Musculoskelet Disord       Date:  2022-09-19       Impact factor: 2.562

6.  The effect of insert conformity and material on total knee replacement wear.

Authors:  Abdellatif Abdelgaied; Claire L Brockett; Feng Liu; Louise M Jennings; Zhongmin Jin; John Fisher
Journal:  Proc Inst Mech Eng H       Date:  2013-12-02       Impact factor: 1.617

7.  A comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements.

Authors:  A Abdelgaied; J Fisher; L M Jennings
Journal:  J Mech Behav Biomed Mater       Date:  2017-11-17
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.