PURPOSE: Metallic dental implants cause severe streaking artefacts in computed tomography (CT) data, which inhibit the correct representation of shape and density of the metal and the surrounding tissue. The aim of this study was to investigate the impact of dental implants on the accuracy of dose calculations in radiation therapy planning and the benefit of metal artefact reduction (MAR). A second aim was to determine the treatment technique which is less sensitive to the presence of metallic implants in terms of dose calculation accuracy. MATERIALS AND METHODS: Phantoms consisting of homogeneous water equivalent material surrounding dental implants were designed. Artefact-containing CT data were corrected using the correct density information. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were calculated on corrected and uncorrected CT data and compared to 2-dimensional dose measurements using GafChromic™ EBT2 films. RESULTS: For all plans the accuracy of dose calculations is significantly higher if performed on corrected CT data (p = 0.015). The agreement of calculated and measured dose distributions is significantly higher for VMAT than for IMRT plans for calculations on uncorrected CT data (p = 0.011) as well as on corrected CT data (p = 0.029). CONCLUSION: For IMRT and VMAT the application of metal artefact reduction significantly increases the agreement of dose calculations with film measurements. VMAT was found to provide the highest accuracy on corrected as well as on uncorrected CT data. VMAT is therefore preferable over IMRT for patients with metallic implants, if plan quality is comparable for the two techniques.
PURPOSE: Metallic dental implants cause severe streaking artefacts in computed tomography (CT) data, which inhibit the correct representation of shape and density of the metal and the surrounding tissue. The aim of this study was to investigate the impact of dental implants on the accuracy of dose calculations in radiation therapy planning and the benefit of metal artefact reduction (MAR). A second aim was to determine the treatment technique which is less sensitive to the presence of metallic implants in terms of dose calculation accuracy. MATERIALS AND METHODS: Phantoms consisting of homogeneous water equivalent material surrounding dental implants were designed. Artefact-containing CT data were corrected using the correct density information. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were calculated on corrected and uncorrected CT data and compared to 2-dimensional dose measurements using GafChromic™ EBT2 films. RESULTS: For all plans the accuracy of dose calculations is significantly higher if performed on corrected CT data (p = 0.015). The agreement of calculated and measured dose distributions is significantly higher for VMAT than for IMRT plans for calculations on uncorrected CT data (p = 0.011) as well as on corrected CT data (p = 0.029). CONCLUSION: For IMRT and VMAT the application of metal artefact reduction significantly increases the agreement of dose calculations with film measurements. VMAT was found to provide the highest accuracy on corrected as well as on uncorrected CT data. VMAT is therefore preferable over IMRT for patients with metallic implants, if plan quality is comparable for the two techniques.
Authors: Frank Schneider; Martin Polednik; Dirk Wolff; Volker Steil; Anna Delana; Frederik Wenz; Loris Menegotti Journal: Z Med Phys Date: 2009 Impact factor: 4.820
Authors: David Palma; Emily Vollans; Kerry James; Sandy Nakano; Vitali Moiseenko; Richard Shaffer; Michael McKenzie; James Morris; Karl Otto Journal: Int J Radiat Oncol Biol Phys Date: 2008-05-01 Impact factor: 7.038
Authors: Sabah Falek; Rajesh Regmi; Joel Herault; Melanie Dore; Anthony Vela; Pauline Dutheil; Cyril Moignier; Pierre-Yves Marcy; Julien Drouet; Arnaud Beddok; Noah E Letwin; Joel Epstein; Upendra Parvathaneni; Juliette Thariat Journal: Support Care Cancer Date: 2022-05-05 Impact factor: 3.359
Authors: Petra M Härtl; Marius Treutwein; Matthias G Hautmann; Manuel März; Fabian Pohl; Oliver Kölbl; Barbara Dobler Journal: Radiat Oncol Date: 2016-06-10 Impact factor: 3.481
Authors: David Gergely Kovacs; Laura A Rechner; Ane L Appelt; Anne K Berthelsen; Junia C Costa; Jeppe Friborg; Gitte F Persson; Jens Peter Bangsgaard; Lena Specht; Marianne C Aznar Journal: Radiother Oncol Date: 2017-10-16 Impact factor: 6.280