Literature DB >> 25283364

Evaluation of intensity of artefacts in CBCT by radio-opacity of composite simulation models of implants in vitro.

N Kuusisto1, P K Vallittu, L V J Lassila, S Huumonen.   

Abstract

OBJECTIVES: The aim was to compare the intensity of artefacts in CBCT images caused by different percentages of radio-opacifying material in composite simulation models of implants. Titanium and zirconia models of implants were used as a reference for the evaluation of the intensity of artefacts.
METHODS: Seven different percentages of radio-opacifying BaAlSiO2 fillers were added to composite resin to fabricate seven step wedges and simulation models of implants. Titanium and zirconia simulation models of implants were also fabricated. Aluminium step wedge was used as a reference for the measurement of grey values in intraoral radiographs. Step wedges were exposed with a Planmeca Intra X-ray machine (Planmeca Oy, Helsinki, Finland). All composite, titanium and zirconia simulation models of implants were exposed with a SCANORA(®) 3D dental X-ray machine (Soredex, Tuusula, Finland). Images and grey values were analysed with ImageJ software (National Institutes of Health, Bethesda, MD). To demonstrate possible artefacts between all the simulation models of implants, the images were also visually compared with each other using ImageJ software.
RESULTS: Artefacts were clearly present in CBCT images caused by titanium and zirconia and when the composite material consisted at least 20% BaAlSiO2. The intensity of artefacts increased when the radio-opacity of the composite material increased.
CONCLUSIONS: Materials containing less radio-opacity produce less pronounced artefacts. The cut-off point for artefacts is at 20% radio-opaque filling material in composite material.

Entities:  

Keywords:  artifact; composite-based implant model; cone beam CT; radio-opacity

Mesh:

Substances:

Year:  2014        PMID: 25283364      PMCID: PMC4614173          DOI: 10.1259/dmfr.20140157

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  33 in total

1.  Quantification of metal artifacts on cone beam computed tomography images.

Authors:  Ruben Pauwels; Harry Stamatakis; Hilde Bosmans; Ria Bogaerts; Reinhilde Jacobs; Keith Horner; Kostas Tsiklakis
Journal:  Clin Oral Implants Res       Date:  2011-12-15       Impact factor: 5.977

2.  Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay): system configuration and physical properties.

Authors:  K Araki; K Maki; K Seki; K Sakamaki; Y Harata; R Sakaino; T Okano; K Seo
Journal:  Dentomaxillofac Radiol       Date:  2004-01       Impact factor: 2.419

3.  Study of the scan uniformity from an i-CAT cone beam computed tomography dental imaging system.

Authors:  J A Bryant; N A Drage; S Richmond
Journal:  Dentomaxillofac Radiol       Date:  2008-10       Impact factor: 2.419

4.  On cone-beam computed tomography artifacts induced by titanium implants.

Authors:  Ralf Kurt Willy Schulze; Dorothea Berndt; Bernd d'Hoedt
Journal:  Clin Oral Implants Res       Date:  2009-10-21       Impact factor: 5.977

5.  In vitro assessment of artifacts induced by titanium dental implants in cone beam computed tomography.

Authors:  Goran I Benic; Manuel Sancho-Puchades; Ronald E Jung; Hans Deyhle; Christoph H F Hämmerle
Journal:  Clin Oral Implants Res       Date:  2012-10-29       Impact factor: 5.977

6.  Radiopacity vs. composition of some barium and strontium glass composites.

Authors:  D C Watts
Journal:  J Dent       Date:  1987-02       Impact factor: 4.379

7.  Further studies on radio-opaque denture-base materials.

Authors:  E C Combe
Journal:  J Dent       Date:  1972-12       Impact factor: 4.379

8.  Physical and mechanical properties of an experimental dental composite based on a new monomer.

Authors:  M Atai; M Nekoomanesh; S A Hashemi; S Amani
Journal:  Dent Mater       Date:  2004-09       Impact factor: 5.304

9.  Effects of monomer ratios and highly radiopaque fillers on degree of conversion and shrinkage-strain of dental resin composites.

Authors:  Amel Amirouche-Korichi; Mohamed Mouzali; David C Watts
Journal:  Dent Mater       Date:  2009-08-15       Impact factor: 5.304

10.  Incorporation of an antibacterial and radiopaque monomer in to dental resin system.

Authors:  Jingwei He; Eva Söderling; Lippo V J Lassila; Pekka K Vallittu
Journal:  Dent Mater       Date:  2012-05-08       Impact factor: 5.304

View more
  10 in total

1.  Metallic materials in the exomass impair cone beam CT voxel values.

Authors:  Amanda P Candemil; Benjamin Salmon; Deborah Q Freitas; Glaucia Mb Ambrosano; Francisco Haiter-Neto; Matheus L Oliveira
Journal:  Dentomaxillofac Radiol       Date:  2018-03-27       Impact factor: 2.419

2.  Evaluation and reduction of magnetic resonance imaging artefacts induced by distinct plates for osseous fixation: an in vitro study @ 3 T.

Authors:  Carsten Rendenbach; Max Schoellchen; Julie Bueschel; Tobias Gauer; Jan Sedlacik; Daniel Kutzner; Pekka K Vallittu; Max Heiland; Ralf Smeets; Jens Fiehler; Susanne Siemonsen
Journal:  Dentomaxillofac Radiol       Date:  2018-05-23       Impact factor: 2.419

3.  Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images.

Authors:  Letícia Queiroz Mauad; Paulo Victor Teixeira Doriguêtto; Daniela de Almeida; Karolina Aparecida Castilho Fardim; Alessiana Helena Machado; Karina Lopes Devito
Journal:  Dentomaxillofac Radiol       Date:  2020-09-17       Impact factor: 2.419

4.  CBCT image artefacts generated by implants located inside the field of view or in the exomass.

Authors:  Husniye Demirturk Kocasarac; Lisa J Koenig; Gulbahar Ustaoglu; Matheus Lima Oliveira; Deborah Queiroz Freitas
Journal:  Dentomaxillofac Radiol       Date:  2021-07-29       Impact factor: 2.419

5.  Effect of Exposure Parameters on Metal Artifacts in Cone Beam Computed Tomography.

Authors:  Mehrdad Panjnoush; Yasaman Kheirandish; Pooneh Mohseni Kashani; Hoorieh Bashizadeh Fakhar; Farzan Younesi; Maysa Mallahi
Journal:  J Dent (Tehran)       Date:  2016-06

6.  Effect of Dental Implant Metal Artifacts on Accuracy of Linear Measurements by Two Cone-Beam Computed Tomography Systems Before and After Crown Restoration.

Authors:  Hoorieh Bashizadeh Fakhar; Roxana Rashtchian; Milad Parvin
Journal:  J Dent (Tehran)       Date:  2017-11

7.  CBCT artefact-burden of zirconia-based as compared to titanium implants for different beam energies: an analytical approach.

Authors:  Ralf Schulze
Journal:  Sci Rep       Date:  2022-09-10       Impact factor: 4.996

Review 8.  Cone beam computed tomography in implant dentistry: recommendations for clinical use.

Authors:  Reinhilde Jacobs; Benjamin Salmon; Marina Codari; Bassam Hassan; Michael M Bornstein
Journal:  BMC Oral Health       Date:  2018-05-15       Impact factor: 2.757

9.  Contrast-to-noise ratios of different dental restorative materials: an in-vitro cone beam computed tomography study.

Authors:  Seval Bayrak; Emine Sebnem Kursun Cakmak; Hakan Kamalak
Journal:  Eur Oral Res       Date:  2020-01-01

10.  Scattering of therapeutic radiation in the presence of craniofacial bone reconstruction materials.

Authors:  Joonas Toivonen; Mikko Björkqvist; Heikki Minn; Pekka K Vallittu; Jami Rekola
Journal:  J Appl Clin Med Phys       Date:  2019-11-29       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.