Literature DB >> 25249516

Cup position alone does not predict risk of dislocation after hip arthroplasty.

Christina I Esposito1, Brian P Gladnick1, Yuo-Yu Lee1, Stephen Lyman1, Timothy M Wright1, David J Mayman1, Douglas E Padgett1.   

Abstract

We used a large prospective institutional registry to determine if there is a 'safe zone' that exists for acetabular component position within which the risk of hip dislocation is low and if other patient and implant factors affect the risk of hip dislocation. Patients who reported a dislocation event within six months after hip arthroplasty surgery were identified, and acetabular component position was measured with anteroposterior radiographs. The frequency of dislocation was 2.1% (147 of 7040 patients). No significant difference was found in the number of dislocated hips among the radiographic zones (±5°,±10°,±15° boundaries). Dislocators <50 years old were less active preoperatively than nondislocators (P=0.006). Acetabular component position alone is not protective against instability.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  arthroplasty; cup orientation; dislocation; hip; safe zone

Mesh:

Year:  2014        PMID: 25249516      PMCID: PMC4270833          DOI: 10.1016/j.arth.2014.07.009

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  41 in total

1.  Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position.

Authors:  Lawrence D Dorr; Aamer Malik; Zhinian Wan; William T Long; Michael Harris
Journal:  Clin Orthop Relat Res       Date:  2007-12       Impact factor: 4.176

Review 2.  Revision total hip arthroplasty for instability: surgical techniques and principles.

Authors:  Javad Parvizi; Elizabeth Picinic; Peter F Sharkey
Journal:  J Bone Joint Surg Am       Date:  2008-05       Impact factor: 5.284

3.  The definition and measurement of acetabular orientation.

Authors:  D W Murray
Journal:  J Bone Joint Surg Br       Date:  1993-03

4.  EBRA: a method to measure migration of acetabular components.

Authors:  M Krismer; R Bauer; J Tschupik; P Mayrhofer
Journal:  J Biomech       Date:  1995-10       Impact factor: 2.712

5.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

6.  Influence of total hip design on dislocation: a computer model and clinical analysis.

Authors:  Douglas E Padgett; Joseph Lipman; Bruce Robie; Bryan J Nestor
Journal:  Clin Orthop Relat Res       Date:  2006-06       Impact factor: 4.176

7.  Pelvic tilt is minimally changed by total hip arthroplasty.

Authors:  William S Murphy; Greg Klingenstein; Stephen B Murphy; Guoyan Zheng
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

8.  Revision of the Charnley low-friction arthroplasty for recurrent or irreducible dislocation.

Authors:  G A Fraser; B M Wroblewski
Journal:  J Bone Joint Surg Br       Date:  1981

9.  Validating California teachers study self-reports of recent hospitalization: comparison with California hospital discharge data.

Authors:  Sarah F Marshall; Dennis Deapen; Mark Allen; Hoda Anton-Culver; Leslie Bernstein; Pamela L Horn-Ross; David Peel; Rich Pinder; Peggy Reynolds; Ronald K Ross; Dee West; Al Ziogas
Journal:  Am J Epidemiol       Date:  2003-11-15       Impact factor: 4.897

10.  Hip spine relationships: application to total hip arthroplasty.

Authors:  J Y Lazennec; A Riwan; F Gravez; M A Rousseau; N Mora; M Gorin; A Lasne; Y Catonne; G Saillant
Journal:  Hip Int       Date:  2007       Impact factor: 2.135

View more
  42 in total

1.  A critical analysis of radiographic factors in patients who develop dislocation after elective primary total hip arthroplasty.

Authors:  Marion Opperer; Yuo-yu Lee; Francisco Nally; Alvaro Blanes Perez; Kaveh Goudarz-Mehdikhani; Alejandro Gonzalez Della Valle
Journal:  Int Orthop       Date:  2015-10-27       Impact factor: 3.075

2.  What Safe Zone? The Vast Majority of Dislocated THAs Are Within the Lewinnek Safe Zone for Acetabular Component Position.

Authors:  Matthew P Abdel; Philipp von Roth; Matthew T Jennings; Arlen D Hanssen; Mark W Pagnano
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

3.  CORR Insights®: What Factors Are Associated With Neck Fracture in One Commonly Used Bimodular THA Design? A Multicenter, Nationwide Study in Slovenia.

Authors:  Lawrence D Dorr
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

4.  Can a simple iPad app improve C-arm based component position in anterior THA?

Authors:  Ulrich Bechler; Bernhard Springer; Kilian Rueckl; Tim Rolvien; Friedrich Boettner
Journal:  Arch Orthop Trauma Surg       Date:  2021-02-13       Impact factor: 3.067

5.  CORR Insights®: 2018 Frank Stinchfield Award: Spinopelvic Hypermobility Is Associated With an Inferior Outcome After THA: Examining the Effect of Spinal Arthrodesis.

Authors:  Laurent Sedel
Journal:  Clin Orthop Relat Res       Date:  2019-02       Impact factor: 4.176

6.  [Measurement of acetabular cup inclination in anteroposterior pelvic radiogram : An indicator of quality after primary total hip arthroplasty?]

Authors:  T Loitsch; T Freitag; F Leucht; H Reichel; R Bieger
Journal:  Orthopade       Date:  2018-12       Impact factor: 1.087

Review 7.  Implications of Spinopelvic Mobility on Total Hip Arthroplasty: Review of Current Literature.

Authors:  John D Attenello; Jeffery K Harpstrite
Journal:  Hawaii J Health Soc Welf       Date:  2019-11

8.  Plan in 2-D, execute in 3-D: an augmented reality solution for cup placement in total hip arthroplasty.

Authors:  Javad Fotouhi; Clayton P Alexander; Mathias Unberath; Giacomo Taylor; Sing Chun Lee; Bernhard Fuerst; Alex Johnson; Greg Osgood; Russell H Taylor; Harpal Khanuja; Mehran Armand; Nassir Navab
Journal:  J Med Imaging (Bellingham)       Date:  2018-01-04

9.  Computerized navigation for total hip arthroplasty is associated with lower complications and ninety-day readmissions: a nationwide linked analysis.

Authors:  Elizabeth B Gausden; Joseph E Popper; Peter K Sculco; Barret Rush
Journal:  Int Orthop       Date:  2020-01-09       Impact factor: 3.075

Review 10.  Sagittal Pelvic Kinematics in Hip Arthroplasty.

Authors:  Thomas E Niemeier; Brad W Wills; Steven M Theiss; Shane F Strom
Journal:  Curr Rev Musculoskelet Med       Date:  2020-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.