| Literature DB >> 25225557 |
Seyed Hamid Raji1, Saeed Noorollahian2, Seyed Mohsen Niknam1.
Abstract
BACKGROUND: Primary stability is an important factor for the clinical success of orthodontic mini-screws. The present study made an attempt to evaluate the effect of insertion angle changes on the maximum insertion and removal torque of orthodontic mini-screws.Entities:
Keywords: Insertion torque; orthodontic mini-screw; removal torque; skeletal anchorage
Year: 2014 PMID: 25225557 PMCID: PMC4163822
Source DB: PubMed Journal: Dent Res J (Isfahan) ISSN: 1735-3327
Figure 1A view of torque testing process and the arrangement of pre-drilled holes (a), mini-screw (b), customized screw driver (c), torque tester/screw driver (e) mounted on the rotating part of the milling machine and poly-carbonate plate fixed in aluminum frame and mounted on the non-rotating part of the milling machine
Insertion and removal torque values (N.Cm) in different Insertion angles