Literature DB >> 22464529

Finite element analysis of miniscrew implants used for orthodontic anchorage.

Te-Chun Liu1, Chih-Han Chang, Tung-Yiu Wong, Jia-Kuang Liu.   

Abstract

INTRODUCTION: The miniscrew has been developed and effectively used as orthodontic anchorage, but current studies of its usage are insufficient to provide information about the underlying mechanical mechanisms. The aim of this study was to investigate the roles of bone quality, loading conditions, screw effects, and implanted depth on the biomechanics of an orthodontic miniscrew system by using finite element analysis.
METHODS: A 3-dimensional model with a bone block integrated with a miniscrew was constructed to simulate various cortex thicknesses, cancellous bone densities, force magnitudes and directions, screw diameters and lengths, and implanted depths of miniscrews.
RESULTS: Both stress and displacement increased with decreasing cortex thickness, whereas cancellous bone density played a minor role in the mechanical response. These 2 indexes were linearly proportional to the force magnitude and produced the highest values when the force was perpendicular to the long axis of the miniscrew. A wider screw provided superior mechanical advantages. The exposed length of the miniscrew was the real factor affecting mechanical performance.
CONCLUSIONS: The screw diameter was the dominant factor for minscrew mechanical responses. Both bone stress and screw displacement decreased with increasing screw diameter and cortex thickness, and decreasing exposed length of the screw, force magnitude, and oblique loading direction.
Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22464529     DOI: 10.1016/j.ajodo.2011.11.012

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  20 in total

1.  Direct versus indirect loading of orthodontic miniscrew implants-an FEM analysis.

Authors:  C Holberg; P Winterhalder; N Holberg; I Rudzki-Janson; A Wichelhaus
Journal:  Clin Oral Investig       Date:  2012-10-31       Impact factor: 3.573

2.  Orthodontic bracket debonding: risk of enamel fracture.

Authors:  Christof Holberg; Philipp Winterhalder; Nikola Holberg; Andrea Wichelhaus; Ingrid Rudzki-Janson
Journal:  Clin Oral Investig       Date:  2013-03-16       Impact factor: 3.573

3.  Indirect miniscrew anchorage: biomechanical loading of the dental anchorage during mandibular molar protraction-an FEM analysis.

Authors:  Christof Holberg; Philipp Winterhalder; Nikola Holberg; Andrea Wichelhaus; Ingrid Rudzki-Janson
Journal:  J Orofac Orthop       Date:  2014-01-23       Impact factor: 1.938

4.  Evaluation of Stress Pattern Caused by Mini-Implant in Mandibular Alveolar Bone with Different Angulations and Retraction Forces: A Three-Dimensional Finite Element Study.

Authors:  Manreet Sidhu; Vinay Kumar Chugh; Kuldeep Dmello; Anurag Mehta; Ankita Chugh; Pradeep Tandon
Journal:  Turk J Orthod       Date:  2020-07-18

5.  Effect of thread depth and thread pitch on the primary stability of miniscrews receiving a torque load : A finite element analysis.

Authors:  Yushan Ye; Weimin Yi; Song Fan; Luodan Zhao; Yansong Yu; Yingjuan Lu; Qinghe Yao; Wei Wang; Shaohai Chang
Journal:  J Orofac Orthop       Date:  2021-09-28       Impact factor: 1.938

6.  Optimization Analysis of Two-Factor Continuous Variable between Thread Depth and Pitch of Microimplant under Toque Force.

Authors:  Yushan Ye; Jiuyang Jiao; Song Fan; Jieying He; Yamei Wang; Qinghe Yao; Wei Wang; Jinsong Li; Shaohai Chang
Journal:  Comput Math Methods Med       Date:  2022-06-20       Impact factor: 2.809

7.  Stress distributions of a bracket type orthodontic miniscrew and the surrounding bone under moment loadings: Three-dimensional finite element analysis.

Authors:  Shabnam Ajami; Ahmad Mina; Seyed Amin Nabavizadeh
Journal:  J Orthod Sci       Date:  2016 Apr-Jun

8.  Effects of placement angle and direction of orthopedic force application on the stability of orthodontic miniscrews.

Authors:  Jihye Lee; Ji Young Kim; Yoon Jeong Choi; Kyung-Ho Kim; Chooryung J Chung
Journal:  Angle Orthod       Date:  2012-12-14       Impact factor: 2.079

Review 9.  Systematic review of mini-implant displacement under orthodontic loading.

Authors:  Manuel Nienkemper; Jörg Handschel; Dieter Drescher
Journal:  Int J Oral Sci       Date:  2013-12-20       Impact factor: 6.344

10.  The effect of insertion angle on orthodontic mini-screw torque.

Authors:  Seyed Hamid Raji; Saeed Noorollahian; Seyed Mohsen Niknam
Journal:  Dent Res J (Isfahan)       Date:  2014-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.