Insertion torque of orthodontic miniscrews according to changes in shape, diameter and length.

Seon-A Lim1, Jung-Yul Cha, Chung-Ju Hwang.   

Abstract

OBJECTIVE: To determine the variation in the insertion torque of orthodontic miniscrews according to the screw length, diameter, and shape.
MATERIALS AND METHODS: The maximum insertion torque (MIT) was measured using a torque tester at a constant speed of 3 rotations per minute. Cylindrical and taper type of miniscrews (Biomaterials Korea Inc, Seoul, Korea) with different lengths, diameters, and pitches were tested.
RESULTS: The results showed that the insertion torque significantly increased with increasing screw length (P < .01). In particular, there was a significant increase in torque with increasing screw length and diameter (P < .01). An analysis of the serial insertion torque of miniscrews revealed the cylindrical type screw to have much higher insertion torque at the incomplete screw thread, while the taper type screw showed a much higher insertion torque at the final inclination part of the screw thread. The insertion torque was affected by the outer diameter, length, and shape in that order.
CONCLUSIONS: An increase in screw diameter can efficiently reinforce the initial stability of the miniscrew, but the proximity of the root at the implanted site should be considered.

Mesh:

Year:  2008        PMID: 18251617     DOI: 10.2319/121206-507.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  36 in total

1.  A prospective, split-mouth, clinical study of orthodontic titanium miniscrews with machined and acid-etched surfaces.

Authors:  Hyo-Jin Park; Sung-Hwan Choi; Yoon Jeong Choi; Young-Bum Park; Kwang-Mahn Kim; Hyung-Seog Yu
Journal:  Angle Orthod       Date:  2018-12-05       Impact factor: 2.079

2.  Surface characteristics and mechanical behavior of retrieved orthodontic microimplants.

Authors:  Lu Lu; Hyo-Sang Park
Journal:  J Zhejiang Univ Sci B       Date:  2018-05       Impact factor: 3.066

3.  Histomorphometric evaluation of the effects of various diode lasers and force levels on orthodontic mini screw stability.

Authors:  Merve Goymen; Eren Isman; Lale Taner; Mehmet Kurkcu
Journal:  Photomed Laser Surg       Date:  2015-01       Impact factor: 2.796

4.  Evaluation of miniscrew stability using an automatic embedding auxiliary skeletal anchorage device.

Authors:  Yasuhiko Oga; Hiroshi Tomonari; Sangho Kwon; Takaharu Kuninori; Takakazu Yagi; Shouichi Miyawaki
Journal:  Angle Orthod       Date:  2018-09-01       Impact factor: 2.079

5.  Expectations, acceptance and preferences of patients in treatment with orthodontic mini-implants: part II: implant removal.

Authors:  Sandra Lehnen; Fraser McDonald; Christoph Bourauel; Andreas Jäger; Martin Baxmann
Journal:  J Orofac Orthop       Date:  2011-07       Impact factor: 1.938

6.  Effects of predrilling depth and implant shape on the mechanical properties of orthodontic mini-implants during the insertion procedure.

Authors:  Keun-Chul Cho; Seung-Hak Baek
Journal:  Angle Orthod       Date:  2011-11-03       Impact factor: 2.079

7.  Angled-predrilling depth and mini-implant shape effects on the mechanical properties of self-drilling orthodontic mini-implants during the angled insertion procedure.

Authors:  Yoon-Young Heo; Keun-Chul Cho; Seung-Hak Baek
Journal:  Angle Orthod       Date:  2012-03-03       Impact factor: 2.079

8.  Factors affecting stresses in cortical bone around miniscrew implants: a three-dimensional finite element study.

Authors:  Ramzi Duaibis; Budi Kusnoto; Raghu Natarajan; Linping Zhao; Carla Evans
Journal:  Angle Orthod       Date:  2012-03-05       Impact factor: 2.079

9.  Mechanical properties of self-drilling orthodontic micro-implants with different diameters.

Authors:  Yan Chen; Hee Moon Kyung; Limin Gao; Won-Jae Yu; Eun-Ju Bae; Sang-Min Kim
Journal:  Angle Orthod       Date:  2010-09       Impact factor: 2.079

10.  An in vitro study of factors affecting the primary stability of orthodontic mini-implants.

Authors:  Lindsy Holm; Susan J Cunningham; Aviva Petrie; Richard R J Cousley
Journal:  Angle Orthod       Date:  2012-05-07       Impact factor: 2.079

View more